Searcharxiv⌕ Search

arXiv · 2611.11160

Design and Performance Evaluation of a Quad-panel Dual-isotope PET Imaging System

Abstract

In simultaneous dual-isotope PET, prompt-gamma-based separation is challenged by the low statistics of triple coincidences and the limited flexibility of coincidence logic for multi-energy event extraction. We designed and evaluated a compact quad-panel dual-isotope PET system without dedicated prompt gamma detectors. The system comprised four orthogonally arranged detector panels, each providing an effective area of 107.0 * 145.5 mm. GPU-accelerated software coincidence processing extracted double- and prompt-gamma-tagged triple coincidences from raw single-photon data. Triple-coincidence images were reconstructed with correlated-random-triple correction using the consistent delayed expectation-maximization method, followed by image-domain isotope separation using a spatially varying scaling factor. System performance was evaluated using phantom and in vivo studies, with emphasis on 68Ga/18F imaging because of the low prompt gamma yield. The system achieved energy resolutions of 15.7%, 12.9% and 10.2% at 511, 1077, and 1275 keV, and a timing resolution of 1.35 ns. In the 68Ga Derenzo, 1.6-mm rods were resolved in double-coincidence images, with 1.2-mm rods partially distinguishable, while 1.6-mm rods remained discernible in triple-coincidence images. The mean prompt gamma detection efficiencies along the three axes ranged from 8.19% to 9.31%. The system sensitivity was 1.12% for doubles with an energy window of 350-650 keV, and 0.068% for triples after random correction with a dual-energy window. The scatter fraction was 27.81%, and the NECR reached 83 kcps at 9.38 MBq for doubles and 106 cps at 21.42 MBq for triples. Phantom and in vivo studies demonstrated successful separation of 18F/68Ga and 18F/124I tracer distributions. By maintaining high-resolution and quantitative imaging performance, the system provides a preclinical platform for multitracer PET studies.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yu Shi, Tengjiao Wang, Sen Yang, Bo Wen, Meng Niu, Yirong Wang, Risheng Yang, Yanyun Liu, Wei Ding, Xiangyu Liu, Fei Kang, Shouping Zhu. 2026-11-08. Design and Performance Evaluation of a Quad-panel Dual-isotope PET Imaging System. https://searcharxiv.com/abs/2611.11160

Citations retain the original authors and DOI and include this site’s record URL. If this discovery service contributed to your research, you can also cite Searcharxiv by Indiciae: BibTeX · RIS.

KEEP EXPLORING

Related papers

Deep Learning-based Multiparametric Quantitative Ultrasound for Hepatic Steatosis Assessment

Quantitative ultrasound (QUS) has shown promise for liver fat quantification in metabolic dysfunction-associated fatty liver disease (MAFLD). Incorporating multiple parameters has demonstrated the potential to outperform single QUS parameter measures. Here, we propose a deep learning-based multiparametric QUS framework that learns effective integration of multiple features from QUS measures to estimate pixel-wise hepatic fat fraction, enabling the detecting of heterogeneous fat accumulation within the liver. We developed a U-Net based network architecture to predict local fat fraction percentages, which takes 2D QUS maps as input and is trained with magnetic resonance imaging-proton density fat fraction (MRI-PDFF) as the ground truth. We extracted 2D QUS maps (H-scan frequency, at-tenuation, Nakagami, and RF/envelope/log-compressed data) and tested various input configura-tions consisting of different combinations of the QUS parameters. We enrolled 30 patients with healthy livers or suspected/confirmed MASLD, and acquired ultrasound RF data, and validated our approach using the patient data. Among all tested input configurations, the model combining H-scan, attenuation, and Nak-agami parameters achieved the best performance, with a Spearman correlation coefficient (Rs) of 0.92 and an area under the curve (AUC) of 0.98. The predicted fat fraction maps exhibited color changes concordant with the gradual increasing in MRI-PDFF, from normal liver to 45% fat ac-cumulation. These findings demonstrate that deep learning can integrate multiparametric QUS in-formation in a fully data-driven manner, providing a localized fat fraction map rather than a single whole-liver value. We anticipate that our deep learning framework can offer potential advantages for future assessment of heterogeneous disease development in liver for more complex, progres-sive liver diseases such as steatohepatitis.

physics.med-ph↗

BEAM3R: Beam's-eye-view architecture with Mamba-3 for implicit dose reconstruction

To enable accurate and rapid photon control point and proton beamlet dose calculation in the DoseRAD2026 challenge, we present BEAM3R, a dose estimation framework operating in beam's-eye-view (BEV). Our core innovation combines a Mamba-3 state-space depth-sequence core with physics-based transport conditioning to model long-range depth transport without expensive 3D convolutions. BEAM3R shares a 2D CNN encoder-decoder architecture for photon and proton dose tasks, processing per-plane BEV slices. Proton beamlets are conditioned on water equivalent thickness and remaining range, encoding the parameters determining Bragg peak position. Photon models use a bidirectional Mamba-3 core to capture dose contributions from materials downstream of the calculation point, while the proton model uses a forward core with learned energy-prefix tokens and a Bragg-peak refinement module. To reduce interpolation artifacts and support high spatial resolution, we introduce axial grid alignment of BEV lattices with CT slices and an implicit super-resolution representation arranged as channels, evaluated by a differentiable Triton-accelerated resampler that reconstructs packed cubic B-spline coefficients directly in CT space. For MRI-based tasks, synthetic CTs (sCT) are generated using a conditional GAN with a SwinUNETR generator and a PatchGAN discriminator. On the preliminary DoseRAD2026 test set, CT-to-photon and CT-to-proton models achieved 1%/1 mm local gamma pass rates of 96.8% and 96.0%, with stratified plan-level MAEs of 0.0041 and 0.0079. Substituting sCT reduced gamma pass rates to 89.7% for photon and 75.4% proton plan level doses, with stratified plan-level MAEs of 0.0093 and 0.0336. Standardised runtimes were 23.4 s and 18.4 s for CT-to-photon and CT-to-proton prediction, increasing to 39.7 s and 42.8 s for the corresponding MRI-based pipelines.

physics.med-ph↗

Dynamic infrared thermography and computed tomography angiography fusion for DIEP flap perforator selection: a novel measurement system

Accurate perforator selection is critical for successful deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. While computed tomography angiography (CTA) provides high-resolution anatomical detail, it lacks functional perfusion assessment. Dynamic infrared thermography (DIRT), in contrast, captures superficial rewarming dynamics but lacks objective anatomical validation. This study presents a standardized multimodal measurement system enabling automated fusion of DIRT with CTA-derived perforator coordinates. The framework integrates controlled thermographic acquisition, real-time hotspot detection, metric spatial calibration, and global one-to-one assignment of thermal hotspots to CTA perforators within a predefined periumbilical region of interest. The workflow was evaluated in 12 patients. Of 46 CTA perforators within the region of interest, 84.8% were successfully linked to thermographic hotspots, with a median spatial offset of 14.74 mm. Automated assignment excluded 76.1% of detected hotspots due to lack of anatomical correspondence, thereby reducing subjective interpretation. The proposed system enables quantitative multimodal validation of functional and anatomical imaging and provides objective support for perforator selection in clinical practice.

physics.med-ph↗