SearcharxivSearch

arXiv subjects

Sébastien Merlet

Publications and source records attributed to Sébastien Merlet.

18 recordsLinked to original sources

Impact of light shift inhomogeneities on the contrast of light pulse atom interferometers

We study the loss of the contrast in an atom interferometer when increasing the duration of Raman mirror pulses, and find the contrast decay rate to increase with the interferometer duration. We attribute this effect to the transverse spatial fluctuations of the intensity across the Raman beams, and to the dephasing induced by the associated light shifts inhomogeneities. Simulations based on the propagation of noisy synthetic Raman beams show that the contrast decay rate increases with the distance between the wavepackets at the mirror pulse, before reaching an asymptotic limit when intensity fluctuations between the two wavepackets become completely decorrelated. Finally, simulations based on the propagation of Raman beams having their measured intensity fluctuations predict contrast loss rates consistent with our measurements, confirming the detrimental role for the interferometer contrast played by intensity fluctuations across the interferometer laser beams.

physics.atom-ph

Stroboscopic Raman Spectroscopy of Atom Optics in Quasi-Bragg Regime

Quasi-Bragg regime is a good compromise for large-momentum-transfer atom interferometry, allowing for scaling up the interferometric area, while constraining the population of unwanted states. Separation of momentum states via standard time of flight methods, however, can be challenging when using laser-cooled atoms, rather than ultracold atoms with sub-recoil velocity distribution. To overcome this limit, we use Raman spectroscopy for stroboscopic sampling of the atomic state evolution in momentum space during the interrogating laser pulses. We quantitatively characterize atom optics employing two-photon (2___k) and multi-photon (6___k) Bragg transitions, the latter being optionally enhanced with optimal control protocol. We closely match the observed dynamics of the atomic state with simulations. Finally, we perform momentum spectroscopy of the output states in a 6___k Bragg gravimeter.

physics.atom-ph

Rejection of wavefront aberrations in an atomic gradiometer

One of the main residual limitations of inertial sensors based on atom interferometry stems from laser beam distortions, which cause parasitic phase shifts and non-homogeneous matter-light couplings. Here we present numerical simulations, accompanied by analytical calculations, which quantify the impact of these effects in a cold atom gradiometer. We demonstrate that the propagation of interferometric laser beam aberrations, combined with initial asymmetry and significant time-of-flight expansion of the the two atomic sources, limit the common-mode rejection of phase noise in a differential configuration. The resulting deviations in gravitational acceleration and its gradient are within reach of current experimental devices. Our study allows us to evaluate the surface quality requirements for retroreflective optics in cold-atom gradiometers of various baselines, and can be extended to other sensors based on different interferometer geometries.

physics.atom-ph

Influence of optical aberrations on the accuracy of an atomic gravimeter

We present numerical simulations of the impact of laser beam wavefront aberrations in cold atom interferometers. We demonstrate that to reach accuracy at the mrad level, simulations cannot be based on a description of the retroreflection optics only with low-order Zernike polynomials, as the results will then depend on the decomposition order and the decomposition technique chosen. Moreover, simulations with high-order Zernike polynomials or equivalently high spatial frequency components require the propagation of aberrations to be taken into account, rather than adding them to the ideally propagated beam. Finally, we examine the impact of the parameters of the atomic source and show that the use of delta-kicked atomic cloud would efficiently mitigate the impact of this systematic effect.

physics.atom-ph

Separating the output ports of a Bragg interferometer via velocity selective transport

We report on the study of a detection scheme based on a Bloch separator in two-photon Bragg interferometers. We increase the spatial separation between the two output ports of the interferometer by selectively imparting 30 Bloch oscillations to one of them before their detection via time of flight. This method allows increasing the duration of the interferometer by reducing the time for discriminating the ports of the interferometer at detection. We study in detail the impact of this separator on the performance of a dual gravity sensor, and in particular on its measurement sensitivities to gravity acceleration and gravity gradients.

physics.atom-ph

A compact differential gravimeter at the quantum projection noise limit

Atom interferometry offers new perspectives for geophysics and inertial sensing. We present the industrial prototype of a new type of quantum-based instrument: a compact, transportable, differential quantum gravimeter capable of measuring simultaneously the absolute values of both gravitational acceleration, $g$, and its vertical gradient, $Γ_{zz}$. While the sensitivity to g is competitive with the best industrial gravimeters, the sensitivity on $Γ_{zz}$ reaches the limit set by quantum projection noise-leading to an unprecedented long-term stability of 0.1 E ($1E=1\times 10^{-9}s^{-2}$). This unique, dual-purpose instrument, paves the way for new applications in geophysics, civil engineering, and gravity-aided navigation, where accurate mapping of the gravitational field plays an important role.

physics.atom-ph

High-accuracy inertial measurements with cold-atom sensors

The research on cold-atom interferometers gathers a large community of about 50 groups worldwide both in the academic and now in the industrial sectors. The interest in this sub-field of quantum sensing and metrology lies in the large panel of possible applications of cold-atom sensors for measuring inertial and gravitational signals with a high level of stability and accuracy. This review presents the evolution of the field over the last 30 years and focuses on the acceleration of the research effort in the last 10 years. The article describes the physics principle of cold-atom gravito-inertial sensors as well as the main parts of hardware and the expertise required when starting the design of such sensors. It then reviews the progress in the development of instruments measuring gravitational and inertial signals, with a highlight on the limitations to the performances of the sensors, on their applications, and on the latest directions of research.

physics.atom-ph

A prototype industrial laser system for cold atom inertial sensing in space

We present the design, realization, characterization and testing of an industrial prototype of a laser system, which is based on frequency doubling of telecom lasers and features all key functionalities to drive a cold atom space gradiometer based on the architecture proposed in [Trimeche et al, 2019]. Testing was performed by implementing the laser system onto a ground based atomic sensor currently under development. The system reaches a Technology Readiness Level (TRL) of 4, corresponding to an operational validation in a controlled environment. The optical architecture of the system can be adapted to other space mission scenarios.

astro-ph.IM

Active Control of Laser Wavefronts in Atom Interferometers

Wavefront aberrations are identified as a major limitation in quantum sensors. They are today the main contribution in the uncertainty budget of best cold atom interferometers based on two-photon laser beam splitters, and constitute an important limit for their long-term stability, impeding these instruments from reaching their full potential. Moreover, they will also remain a major obstacle in future experiments based on large momentum beam splitters. In this article, we tackle this issue by using a deformable mirror to control actively the laser wavefronts in atom interferometry. In particular, we demonstrate in an experimental proof of principle the efficient correction of wavefront aberrations in an atomic gravimeter.

physics.atom-ph

Coherent population trapping in a Raman atom interferometer

We investigate the effect of coherent population trapping (CPT) in an atom inter-ferometer gravimeter based on the use of stimulated Raman transitions. We find that CPT leads to significant phase shifts, of order of a few mrad, which may compromise the accuracy of inertial measurements. We show that this effect is rejected by the k-reversal technique, which consists in averaging inertial measurements performed with two opposite orientations of the Raman wavevector k, provided that internal states at the input of the interferometer are kept identical for both configurations.

physics.atom-ph

A simple laser system for atom interferometry

We present here a simple laser system for a laser cooled atom interferometer, where all functions (laser cooling, interferometry and detection) are realized using only two extended cavity laser diodes, amplified by a common tapered amplifier. One laser is locked by frequency modulation transfer spectroscopy, the other being phase locked with an offset frequency determined by an Field-Programmable Gate Array (FPGA) controlled Direct Digital Synthesizer (DDS), which allows for efficient and versatile tuning of the laser frequency. Raman lasers are obtained with a double pass acousto-optic modulator. We demonstrate a gravimeter using this laser system, with performances close to the state of the art.

physics.atom-ph

Effective velocity distribution in an atom gravimeter: effect of the convolution with the response of the detection

We present here a detailed study of the influence of the transverse motion of the atoms in a free-fall gravimeter. By implementing Raman selection in the horizontal directions at the beginning of the atoms free fall, we characterize the effective velocity distribution, ie the velocity distribution of the detected atom, as a function of the laser cooling and trapping parameters. In particular, we show that the response of the detection induces a pronounced asymetry of this effective velocity distribution that depends not only on the imbalance between molasses beams but also on the initial position of the displaced atomic sample. This convolution with the detection has a strong influence on the averaging of the bias due to Coriolis acceleration. The present study allows a fairly good understanding of results previously published in {\it Louchet-Chauvet et al., NJP 13, 065025 (2011)}, where the mean phase shift due to Coriolis acceleration was found to have a sign different from expected.

physics.atom-ph

Stability comparison of two absolute gravimeters: optical versus atomic interferometers

We report the direct comparison between the stabilities of two mobile absolute gravimeters of different technology: the LNE-SYRTE Cold Atom Gravimeter and FG5X\#216 of the Université du Luxembourg. These instruments rely on two different principles of operation: atomic and optical interferometry. The comparison took place in the Walferdange Underground Laboratory for Geodynamics in Luxembourg, at the beginning of the last International Comparison of Absolute Gravimeters, ICAG-2013. We analyse a 2h10 duration common measurement, and find that the CAG shows better immunity with respect to changes in the level of vibration noise, as well as a slightly better short term stability.

physics.atom-ph

Underground operation at best sensitivity of the mobile LNE-SYRTE Cold Atom Gravimeter

Low noise underground environments offer conditions allowing to assess ultimate performance of high sensitivity sensors such as accelerometers, gyrometers, seismometers... Such facilities are for instance ideal for observing the tiny signals of interest for geophysical studies. Laboratoire Souterrain à Bas Bruit (LSBB) in which we have installed our cold atom gravimeter, provides such an environment. We report here the best short term sensitivity ever obtained without any ground vibration isolation system with such an instrument: $10^{-8}$m.s$^{-2}$ in 100 s measurement time.

physics.atom-ph

A cold atom pyramidal gravimeter with a single laser beam

We demonstrate a scheme for realizing a compact cold atom gravimeter. The use of a hollow pyramidal configuration allows to achieve all functions: trapping, interferometer and detection with a unique laser beam leading to a drastic reduction in complexity and volume. In particular, we demonstrate a relative sensitivity to acceleration of gravity (g) of 1.7 x 10-7 at one second, with a moderate laser power of 50 mW. This simple geometry combined to such a high sensitivity opens wide perspectives for practical applications (P. Bouyer and A. Landragin, patent number FR2009/000252, 2009).

physics.atom-ph

Double diffraction in an atomic gravimeter

We demonstrate the realization of a new scheme for cold atom gravimetry based on the use of double diffraction beamsplitters recently demonstrated in \cite{Leveque}, where the use of two retro-reflected Raman beams allows symmetric diffraction in $\pm \hbar k_{eff}$ momenta. Though in principle restricted to the case of zero Doppler shift, for which the two pairs of Raman beams are simultaneously resonant, we demonstrate that such diffraction pulses can remain efficient on atoms with non zero velocity, such as in a gravimeter, when modulating the frequency of one of the two Raman laser sources. We use such pulses to realize an interferometer insensitive to laser phase noise and some of the dominant systematics. This reduces the technical requirements and would allow the realization of a simple atomic gravimeter. We demonstrate a sensitivity of $1.2\times10^{-7}g$ per shot.

physics.atom-ph

Operating an atom interferometer beyond its linear range

In this paper, we show that an atom interferometer inertial sensor, when associated to the auxiliary measurement of external vibrations, can be operated beyond its linear range and still keep a high acceleration sensitivity. We propose and compare two measurement procedures (fringe fitting and nonlinear lock) that can be used to extract the mean phase of the interferometer when the interferometer phase fluctuations exceed $2π$. Despite operating in the urban environment of inner Paris without any vibration isolation, the use of a low noise seismometer for the measurement of ground vibrations allows our atom gravimeter to reach at night a sensitivity as good as $5.5\times10^{-8}$g at 1 s. Robustness of the measurement to large vibration noise is also demonstrated by the ability of our gravimeter to operate during an earthquake with excellent sensitivity. Our high repetition rate allows for recovering the true low frequency seismic vibrations, ensuring proper averaging. Such techniques open new perspectives for applications in other fields, such as navigation and geophysics.

physics.atom-ph

Limits to the sensitivity of a low noise compact atomic gravimeter

A detailed analysis of the most relevant sources of phase noise in an atomic interferometer is carried out, both theoretically and experimentally. Even a short interrogation time of 100 ms allows our cold atom gravimeter to reach an excellent short term sensitivity to acceleration of $1.4\times 10^{-8}$g at 1s. This result relies on the combination of a low phase noise laser system, efficient detection scheme and good shielding from vibrations. In particular, we describe a simple and robust technique of vibration compensation, which is based on correcting the interferometer signal by using the AC acceleration signal measured by a low noise seismometer.

physics.atom-ph