Searcharxiv⌕ Search

arXiv subjects

S. Biswas

Publications and source records attributed to S. Biswas.

At least 91 records · Page 5Linked to original sources

Studies of the effect of rate on gain for straw tube detector

Basic R & D have been carried out with one small straw tube detector prototype with premixed gas of Ar+CO2 in 70:30 and 90:10 ratio. The gain and the energy resolution are measured with Fe55 X-ray source. Effect of temperature and pressure on these parameters are measured. The variation of gain and energy resolution with rate per unit length are also measured. The details of the test set-up, the method of measurement and the test results are presented in this paper.

physics.ins-det↗

Longitudinal Wobbling in $^{133}$La

Excited states of $^{133}$La have been investigated to search for the wobbling excitation mode in the low-spin regime. Wobbling bands with $n_ω$ = 0 and 1 are identified along with the interconnecting $ΔI$ = 1, $E2$ transitions, which are regarded as one of the characteristic features of the wobbling motion. An increase in wobbling frequency with spin implies longitudinal wobbling for $^{133}$La, in contrast with the case of transverse wobbling observed in $^{135}$Pr. This is the first observation of a longitudinal wobbling band in nuclei. The experimental observations are accounted for by calculations using the quasiparticle-triaxial-rotor (QTR) model, which attribute the appearance of longitudinal wobbling to the early alignment of a $π=+$ proton pair.

nucl-ex↗

Challenges in QCD matter physics - The Compressed Baryonic Matter experiment at FAIR

Substantial experimental and theoretical efforts worldwide are devoted to explore the phase diagram of strongly interacting matter. At LHC and top RHIC energies, QCD matter is studied at very high temperatures and nearly vanishing net-baryon densities. There is evidence that a Quark-Gluon-Plasma (QGP) was created at experiments at RHIC and LHC. The transition from the QGP back to the hadron gas is found to be a smooth cross over. For larger net-baryon densities and lower temperatures, it is expected that the QCD phase diagram exhibits a rich structure, such as a first-order phase transition between hadronic and partonic matter which terminates in a critical point, or exotic phases like quarkyonic matter. The discovery of these landmarks would be a breakthrough in our understanding of the strong interaction and is therefore in the focus of various high-energy heavy-ion research programs. The Compressed Baryonic Matter (CBM) experiment at FAIR will play a unique role in the exploration of the QCD phase diagram in the region of high net-baryon densities, because it is designed to run at unprecedented interaction rates. High-rate operation is the key prerequisite for high-precision measurements of multi-differential observables and of rare diagnostic probes which are sensitive to the dense phase of the nuclear fireball. The goal of the CBM experiment at SIS100 (sqrt(s_NN) = 2.7 - 4.9 GeV) is to discover fundamental properties of QCD matter: the phase structure at large baryon-chemical potentials (mu_B > 500 MeV), effects of chiral symmetry, and the equation-of-state at high density as it is expected to occur in the core of neutron stars. In this article, we review the motivation for and the physics programme of CBM, including activities before the start of data taking in 2022, in the context of the worldwide efforts to explore high-density QCD matter.

nucl-ex↗

Physics Behind Precision

This document provides a writeup of contributions to the FCC-ee mini-workshop on "Physics behind precision" held at CERN, on 2-3 February 2016.

hep-ph↗

Coherent and incoherent aspects of polariton dynamics in semiconductor microcavities

The interaction between coherent polaritons and incoherent excitons plays an important role in polariton physics. Using resonant pump-probe spectroscopy with selective excitation of single polariton branches, we investigate the different dephasing mechanisms responsible for generating a long-lived exciton reservoir. As expected, pumping the upper polariton results in a strong dephasing process that leads to the generation of a long lived reservoir. Unexpectedly, we observe an efficient reservoir creation while exciting only the lower polariton branch when the detuning is increased towards positive detuning. We propose a simple theoretical model, the polaritonic Bloch equations, to describe the dynamics of the system.

cond-mat.mes-hall↗

Building of a 4-channel TTL scaler for counting detector signals

A scaler has been fabricated to count the signals from any radiation de- tector. It can count signals of frequency up to 140 kHz. Transistor Transistor Logic (TTL) is used in this scaler. In this article the details of the design, fabrication and operation processes of the scaler is presented.

physics.ins-det↗

Long-term stability test of a triple GEM detector

The main aim of the study is to perform the long-term stability test of gain of the single mask triple GEM detector. A simple method is used for this long- term stability test using a radioactive X-ray source with high activity. The test is continued till accumulation of charge per unit area > 12.0 mC/mm2. The details of the chamber fabrication, the test set-up, the method of measurement and the test results are presented in this paper.

physics.ins-det↗

Design and fabrication of a data logger for atmospheric pressure, temperature and relative humidity for gas-filled detector development

A novel instrument has been developed to monitor and record the ambient pa- rameters such as temperature, atmospheric pressure and relative humidity. These parameters are very essential for understanding the characteristics such as gain of gas filled detectors like Gas Electron Multiplier (GEM) and Multi Wire Propor- tional Counter (MWPC). In this article the details of the design, fabrication and operation processes of the device has been presented.

physics.ins-det↗

Systematic measurements of the gain and the energy resolution of single and double mask GEM detectors

Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution have also been measured varying either the drift voltage, transfer voltage and induction voltage keeping other voltages constant. The results of the systematic measurements has been presented.

physics.ins-det↗

Characterizations of GEM detector prototype

At NISER-IoP detector laboratory an initiative is taken to build and test Gas Electron Multiplier (GEM) detectors for ALICE experiment. The optimisation of the gas flow rate and the long-term stability test of the GEM detector are performed. The method and test results are presented.

physics.ins-det↗

A simple technique for gamma ray and cosmic ray spectroscopy using plastic scintillator

A new and simple technique has been developed using plastic scintillator detectors for gamma ray and cosmic ray spectroscopy without single channel analyzer (SCA) or multichannel analyzer (MCA). In these experiments only a leading edge discriminator (LED) and NIM scalers have been used. Energy calibration of gamma spectra in plastic scintillators has been done using Co$^{60}$ and Cs$^{137}$ sources. The details experimental technique, analysis procedure and experimental results has been presented in this article.

physics.ins-det↗

Resonant Slepton Production Yields CMS $eejj$ and $ejj$ Missing $p_T$ Excesses

Recent CMS searches for di-leptoquark production report local excesses of 2.4$σ$ in a $eejj$ channel and 2.6$σ$ in a $ejj$ missing $p_T$ channel. Here, we simultaneously explain both excesses with resonant slepton production in ${\mathcal R}-$parity violating supersymmetry (SUSY). We consider resonant slepton production, which decays to a lepton and a chargino/neutralino, followed by three-body decays of the neutralino/chargino via an $\mathcal{R}-$parity violating coupling. There are regions of parameter space which are also compatible at the 95% confidence level (CL) with a 2.8$σ$ $eejj$ excess in a recent CMS $W_R$ search, while being compatible with other direct search constraints. Phase-II of the GERDA neutrinoless double beta decay ($0νββ$) experiment will probe a sizeable portion of the good-fit region.

hep-ph↗

Study of the characteristics of GEM detectors for the future FAIR experiment CBM

Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas mixtures and with different gas flow rates. Long-term test of the GEM has also been performed.

physics.ins-det↗

Development of Multi-gap Resistive Plate Chamber (MRPC) for medical imaging

The low cost and high resolution Multi-gap Resistive Plate Chamber (MRPC) opens up a new possibility to find an efficient alternative detector for the Time of Flight (TOF) based Positron Emission Tomography, where the sensitivity of the system depends largely on the time resolution of the detector. In a layered structure, suitable converters can be used to increase the photon detection efficiency. In this paper results of the cosmic ray test of a four-gap bakelite-based prototype MRPC operated in streamer mode and six-gap glass-based MRPC operated in avalanche mode are discussed.

physics.ins-det↗

Calibration and performance of the STAR Muon Telescope Detector using cosmic rays

We report the timing and spatial resolution from the Muon Telescope Detector (MTD) installed in the STAR experiment at RHIC. Cosmic ray muons traversing the STAR detector have an average transverse momentum of 6 GeV/c. Due to their very small multiple scattering, these cosmic muons provide an ideal tool to calibrate the detectors and measure their timing and spatial resolution. The values obtained were ~100 ps and ~1-2 cm, respectively. These values are comparable to those obtained from cosmic-ray bench tests and test beams.

physics.ins-det↗

Exploring the origin of degenerate doublet bands in $^{106}$Ag

The electromagnetic transition probabilities of the excited levels for the two nearly degenerate bands of $^{106}$Ag have been measured using the Doppler Shift Attenuation Method. A comparison with the calculated values using triaxial projected shell model approach indicates that these bands originate from two different quasi-particle configurations but constructed from the same mean-field deformation.

nucl-ex↗

Development of a GEM based detector for the CBM Muon Chamber (MUCH)

The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated varying both the rate and the value of the protection resistor. This measurement has been performed using both X-ray generator and Fe55 source. The ageing and long-term stability of GEM based detectors has been studied employing both X-ray generator and Fe55 source. The ageing study of one GEM module is performed by using a 8 keV Cu X-ray generator to verify the stability and integrity of the GEM detectors over a longer period of time. The accumulated charge on the detector is calculated from the rate of the X-ray and the average gain of the detector. The details of the measurement and results has been described in this article.

physics.ins-det↗