Searcharxiv⌕ Search

arXiv subjects

S. Cebrian

Publications and source records attributed to S. Cebrian.

At least 55 records · Page 3Linked to original sources

Results of the material screening program of the NEXT experiment

The 'Neutrino Experiment with a Xenon TPC (NEXT)', intended to investigate neutrinoless double beta decay, requires extremely low background levels. An extensive material screening and selection process to assess the radioactivity of components is underway combining several techniques, including germanium gamma-ray spectrometry performed at the Canfranc Underground Laboratory; recent results of this material screening program are presented here.

physics.ins-det↗

ANAIS: Status and prospects

ANAIS (Annual modulation with NAI Scintillators) experiment aims to look for dark matter annual modulation with 250 kg of ultrapure NaI(Tl) scintillators at the Canfranc Underground Laboratory (LSC), in order to confirm the DAMA/LIBRA positive signal in a model-independent way. The detector will consist in an array of close-packed single modules, each of them coupled to two high efficiency Hamamatsu photomultipliers. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra are currently taking data at the LSC. These modules have shown an outstanding light collection efficiency (12-16 phe/keV), about the double of that from DAMA/LIBRA phase 1 detectors, which could enable reducing the energy threshold down to 1 keVee. ANAIS crystal radiopurity goals are fulfilled for 232Th and 238U chains, assuming equilibrium, and in the case of 40K, present crystals activity (although not at the required 20 ppb level) could be acceptable. However, a 210Pb contamination out-of-equilibrium has been identified and its origin traced back, so we expect it will be avoided in next prototypes. Finally, current status and prospects of the experiment considering several exposure and background scenarios are presented.

astro-ph.IM↗

Study of scintillation in natural and synthetic quartz and methacrylate

Samples from different materials typically used as optical windows or light guides in scintillation detectors were studied in a very low background environment, at the Canfranc Underground Laboratory, searching for scintillation. A positive result can be confirmed for natural quartz: two distinct scintillation components have been identified, not being excited by an external gamma source. Although similar effect has not been observed neither for synthetic quartz nor for methacrylate, a fast light emission excited by intense gamma flux is evidenced for all the samples in our measurements. These results could affect the use of these materials in low energy applications of scintillation detectors requiring low radioactive background conditions, as they entail a source of background.

physics.optics↗

Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy $γ$-rays

NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0νββ$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $γ$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($ε$ = 26, 30, 59.5 keV). The localized nature of such events above atmospheric pressure, the long drift times, as well as the possibility to determine their production time from the associated $α$ particle in coincidence, allow the extraction of primordial properties of the TPC filling gas, namely the drift velocity, diffusion and attachment coefficients. In this work we focus on the little explored combination of Xe and trimethylamine (TMA) for which, in particular, such properties are largely unknown. This gas mixture offers potential advantages over pure Xenon when aimed at Rare Event Searches, mainly due to its Penning characteristics, wave-length shifting properties and reduced diffusion, and it is being actively investigated by our collaboration. The chamber is currently operated at 2.7 bar, as an intermediate step towards the envisaged 10 bar. We report here its performance as well as a first implementation of the calibration procedures that have allowed the extension of the previously reported energy resolution to the whole readout plane (10.6%FWHM@30keV).

physics.ins-det↗

Pattern recognition techniques to reduce backgrounds in the search for the 136Xe double beta decay with gaseous TPCs

The observation of the neutrinoless double beta decay may provide essential information on the nature of neutrinos. Among the current experimental approaches, a high pressure gaseous TPC is an attractive option for the search of double beta decay due to its good energy resolution and the detailed topological information of each event. We present in this talk a detailed study of the ionization topology of the 136Xe double beta decay events in a High Pressure Xenon TPC, as well as that of the typical competing backgrounds. We define some observables based on graph theory concepts to develop automated discrimination algorithms. Our criteria are able to reduce the background level by about three orders of magnitude in the region of interest of the 136Xe Qbb for a signal acceptance of 40%. This result provides a quantitative assessment of the benefit of topological information offered by gaseous TPCs for double beta decay search, and proves that it is a promising feature in view of future experiments in the field. Possible ideas for further improvement in the discrimination algorithms and the dependency of these results with the gas diffusion and readout granularity will be also discussed.

physics.ins-det↗

Radiopurity control in the NEXT-100 double beta decay experiment: procedures and initial measurements

The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate the neutrinoless double beta decay of 136Xe, which requires a severe suppression of potential backgrounds. An extensive screening and material selection process is underway for NEXT since the control of the radiopurity levels of the materials to be used in the experimental set-up is a must for rare event searches. First measurements based on Glow Discharge Mass Spectrometry and gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) are described here. Activity results for natural radioactive chains and other common radionuclides are summarized, being the values obtained for some materials like copper and stainless steel very competitive. The implications of these results for the NEXT experiment are also discussed.

physics.ins-det↗

Search for solar axion emission from 7Li and D(p,gamma)3He nuclear decays with the CAST gamma-ray calorimeter

We present the results of a search for a high-energy axion emission signal from 7Li (0.478 MeV) and D(p,gamma)3He (5.5 MeV) nuclear transitions using a low-background gamma-ray calorimeter during Phase I of the CAST experiment. These so-called "hadronic axions" could provide a solution to the long-standing strong-CP problem and can be emitted from the solar core from nuclear M1 transitions. This is the first such search for high-energy pseudoscalar bosons with couplings to nucleons conducted using a helioscope approach. No excess signal above background was found.

hep-ex↗

The case for a directional dark matter detector and the status of current experimental efforts

We present the case for a dark matter detector with directional sensitivity. This document was developed at the 2009 CYGNUS workshop on directional dark matter detection, and contains contributions from theorists and experimental groups in the field. We describe the need for a dark matter detector with directional sensitivity; each directional dark matter experiment presents their project's status; and we close with a feasibility study for scaling up to a one ton directional detector, which would cost around $150M.

astro-ph.CO↗

NEXT, a HPGXe TPC for neutrinoless double beta decay searches

We propose a novel detection concept for neutrinoless double-beta decay searches. This concept is based on a Time Projection Chamber (TPC) filled with high-pressure gaseous xenon, and with separated-function capabilities for calorimetry and tracking. Thanks to its excellent energy resolution, together with its powerful background rejection provided by the distinct double-beta decay topological signature, the design discussed in this Letter Of Intent promises to be competitive and possibly out-perform existing proposals for next-generation neutrinoless double-beta decay experiments. We discuss the detection principles, design specifications, physics potential and R&D plans to construct a detector with 100 kg fiducial mass in the double-beta decay emitting isotope Xe(136), to be installed in the Canfranc Underground Laboratory.

hep-ex↗

Results from a search for the $0νββ$-decay of $^{130}Te$

A detailed description of the CUORICINO $^{130}Te$ neutrinoless double-beta ($\nbb$) decay experiment is given and recent results are reported. CUORICINO is an array of 62 tellurium oxide ($TeO_{2}$) bolometers with an active mass of 40.7 kg. It is cooled to $\sim 8-10$ mK by a dilution refrigerator shielded from environmental radioactivity and energetic neutrons. It is running in the Laboratori Nazionali del Gran Sasso (LNGS) in Assergi, Italy. These data represent an exposure of $11.83\textrm{kg}...\textrm{y}$ or 91 mole-years of $^{130}Te$. No evidence for $\nbb$-decay was observed and a limit of $T^{0ν}_{1/2}(^{130}Te)\geq3.0\times10^{24}$ y (90% C.L.) is set. This corresponds to an upper limit on the effective mass, $< m_ν>$, between 0.19 and 0.68 eV when analyzed with the many published nuclear structure calculations. In the context of these nuclear models, the values fall within the range corresponding to the claim of evidence of $\nbb$-decay by H.V. Klapdor-Kleingrothaus, \textit{et al.} The experiment continues to acquire data.

hep-ex↗

Health and cleanliness of the XMM-Newton science payload since launch

On December 10th 2004 the XMM-Newton observatory celebrated its 5th year in orbit. Since the beginning of the mission steady health and contamination monitoring has been performed by the XMM-Newton SOC and the instrument teams. Main targets of the monitoring, using scientific data for all instruments on board, are the behaviour of the Charge Transfer Efficiency, the gain, the effective area and the bad, hot and noisy pixels. The monitoring is performed by combination of calibration observations using internal radioactive calibration sources with observations of astronomical targets. In addition a set of housekeeping parameters is continuously monitored reflecting the health situation of the instruments from an engineering point of view. We show trend behaviour over the 5 years especially in combination with events like solar flares and other events affecting the performance of the instruments.

astro-ph↗

A New Limit on the Neutrinoless DBD of 130Te

We report the present results of CUORICINO a cryogenic experiment on neutrinoless double beta decay (DBD) of 130Te consisting of an array of 62 crystals of TeO2 with a total active mass of 40.7 kg. The array is framed inside of a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and operated at a temperature of ~8 mK in the Gran Sasso Underground Laboratory. Temperature pulses induced by particle interacting in the crystals are recorded and measured by means of Neutron Transmutation Doped thermistors. The gain of each bolometer is stabilized with voltage pulses developed by a high stability pulse generator across heater resistors put in thermal contact with the absorber. The calibration is performed by means of two thoriated wires routinely inserted in the set-up. No evidence for a peak indicating neutrinoless DBD of 130Te is detected and a 90% C.L. lower limit of 1.8E24 years is set for the lifetime of this process. Taking largely into account the uncertainties in the theoretical values of nuclear matrix elements, this implies an upper boud on the effective mass of the electron neutrino ranging from 0.2 to 1.1 eV. This sensitivity is similar to those of the 76Ge experiments.

hep-ex↗

Neutron background at the Canfranc Underground Laboratory and its contribution to the IGEX-DM dark matter experiment

A quantitative study of the neutron environment in the Canfranc Underground Laboratory has been performed. The analysis is based on a complete set of simulations and, particularly, it is focused on the IGEX-DM dark matter experiment. The simulations are compared to the IGEX-DM low energy data obtained with different shielding conditions. The results of the study allow us to conclude, with respect to the IGEX-DM background, that the main neutron population, coming from radioactivity from the surrounding rock, is practically eliminated after the implementation of a suitable neutron shielding. The remaining neutron background (muon-induced neutrons in the shielding and in the rock) is substantially below the present background level thanks to the muon veto system. In addition, the present analysis gives us a further insight on the effect of neutrons in other current and future experiments at the Canfranc Underground Laboratory. The comparison of simulations with the body of data available has allowed to set the flux of neutrons from radioactivity of the Canfranc rock, (3.82 +- 0.44) x 10^{-6} cm^{-2} s^{-1}, as well as the flux of muon-induced neutrons in the rock, (1.73 +- 0.22(stat) \+- 0.69(syst)) x 10^{-9} cm^{-2} s^{-1}, or the rate of neutron production by muons in the lead shielding, (4.8 +- 0.6 (stat) +- 1.9 (syst)) x 10^{-9} cm^{-3} s^{-1}.

hep-ex↗

Using Wavelets to reject background in Dark Matter experiments

A method based on wavelet techniques has been developed and applied to background rejection in the data of the IGEX dark matter experiment. The method is presented and described in some detail to show how it efficiently rejects events coming from noise and microphonism through a mathematical inspection of their recorded pulse shape. The result of the application of the method to the last data of IGEX is presented.

hep-ex↗

Pulse Shape Discrimination in the IGEX Experiment

The IGEX experiment has been operating enriched germanium detectors in the Canfranc Underground Laboratory (Spain) in a search for the neutrinoless double decay of 76Ge. The implementation of Pulse Shape Discrimination techniques to reduce the radioactive background is described in detail. This analysis has been applied to a fraction of the IGEX data, leading to a rejection of ~60 % of their background, in the region of interest (from 2 to 2.5 MeV), down to ~0.09 c/(keV kg y).

hep-ex↗

CUORE: A Cryogenic Underground Observatory for Rare Events

CUORE is a proposed tightly packed array of 1000 TeO2 bolometers, each being a cube 5 cm on a side with a mass of 760 g. The array consists of 25 vertical towers, arranged in a square of 5 towers by 5 towers, each containing 10 layers of 4 crystals. The design of the detector is optimized for ultralow-background searches: for neutrinoless double beta decay of 130Te (33.8% abundance), cold dark matter, solar axions, and rare nuclear decays. A preliminary experiment involving 20 crystals 3x3x6 cm3 of 340 g has been completed, and a single CUORE tower is being constructed as a smaller scale experiment called CUORICINO. The expected performance and sensitivity, based on Monte Carlo simulations and extrapolations of present results, are reported.

hep-ex↗

Status of IGEX dark matter search at Canfranc Underground Laboratory

One IGEX 76Ge double-beta decay detector is currently operating in the Canfranc Underground Laboratory in a search for dark matter WIMPs, through the Ge nuclear recoil produced by the WIMP elastic scattering. In this talk we report on the on-going efforts to understand and eventually reject the background at low energy. These efforts have led to the improvement of the neutron shielding and to partial reduction of the background, but still the remaining events are not totally identified. A tritium contamination or muon-induced neutrons are considered as possible sources, simulations and experimental test being still under progress. According to the success of this study we comment the prospects of the experiment as well as those of its future extension, the GEDEON dark matter experiment.

astro-ph↗

Status of the ANAIS experiment at Canfranc

The present status of the ANAIS experiment (Annual Modulation with NaI's) is shown. ANAIS is intended to use more than 100 kg of NaI(Tl) in the Canfranc Underground Laboratory (Spain) searching for seasonal modulation effects in the WIMP signal; in a first stage, a prototype (one single 10.7 kg crystal) has been developed in order to obtain the best conditions regarding the energy threshold and the radioactive background in the low energy region as well as to check the stability of the environmental conditions. The first results corresponding to an exposure of 2069.85 kg day show an average background level of 1.2 counts/(keV kg day) from threshold ($E_{thr} \sim 4$ keV, even using one single photomultiplier) up to 10 keV.

hep-ex↗