The Super Fine-Grained Detector for the T2K neutrino oscillation experiment

The magnetised near detector ND280 of the long-baseline neutrino experiment T2K has been upgraded to improve its detection performance and, consequently, enhance our understanding of neutrino-nucleus interactions, reducing the systematic uncertainties in measurements of the neutrino oscillation parameters. A key component of the upgrade is a novel segmented plastic scintillator detector, called the Super Fine-Grained Detector (SuperFGD), made of approximately 2 million optically isolated 1 cm$^3$ cubes read out by three orthogonal wavelength-shifting (WLS) fibres. Scintillation photons are detected by 55,888 Hamamatsu Multi-Pixel Photon Counters (MPPCs). The SuperFGD provides 3D images of neutrino interactions by tracking the final-state charged particles produced isotropically, including protons down to a threshold of around 330 MeV/$c$. The high light yield of SuperFGD greatly improves particle identification and the sub-nanosecond time resolution provides an excellent identification of Michel electrons. The SuperFGD is also able to detect neutrons from neutrino interactions and, for the first time in a neutrino experiment, to reconstruct their kinetic energy using a fine detector segmentation and by measuring the time-of-flight with sub-nanosecond precision. In this article the details of the detector design, construction and performance are described. The detector was installed in ND280 and successfully commissioned with cosmic data in 2023 and, later, with the T2K neutrino beam. The detector response has been characterised with the 2023 and 2024 data and the results are reported in this article.

physics.ins-det

Introducing a Markov Chain-Based Time Calibration Procedure for Multi-Channel Particle Detectors: Application to the SuperFGD and ToF Detectors of the T2K Experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

physics.ins-det

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector

The magnetised near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrinonucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm3 cubes. It will provide a 3D image of GeV neutrino interactions by combining tracking and stopping power measurements of final state particles with sub-nanosecond time resolution. The performance of SuperFGD is characterized by the precision of its response to charged particles as well as the systematic effects that might affect the physics measurements. Hence, a detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

hep-ex

New determination of the branching ratio of the structure dependent radiative $K^{+} \to e^{+} ν_{e} γ$ decay

The branching ratio of the structure dependent (SD) radiative $K^{+} \to e^{+} ν_{e} γ$ decay relative to that of the $K^+\rightarrow e^+ ν_{e} (γ)$ decay including the internal bremsstrahlung (IB) process ($K_{e2(γ)}$) has been measured in the J-PARC E36 experiment using plastic scintillator/lead sandwich detectors. In the analysis, the effect of IB was also taken into account in the SD radiative decay as $K_{e2γ(γ)}^{\rm SD}$. By combining the new data with the previously reported result of the E36 experiment using a CsI(Tl) calorimeter after revision for the IB correction for $K_{e2γ(γ)}^{\rm SD}$, a new value $Br(K_{e2γ(γ)}^{\rm SD})/Br(K_{e2(γ)})=1.20\pm0.07$ has been determined, which is consistent with a recent lattice QCD calculation, but larger than the expectation of Chiral Perturbation Theory (ChPT) at order $O(p^4)$ and the previous KLOE value. Also, using the method to relate form factor and branching ratio described in the KLOE paper, the present result is consistent with the form factor prediction based on a gauged nonlocal chiral quark model, but larger than ChPT at order $O(p^6)$.

hep-ex

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

physics.ins-det

Measurement of structure dependent radiative $K^{+} \rightarrow e^{+} νγ$ decays using stopped positive kaons

The structure dependent radiative $K^+ \rightarrow e^+ νγ$ ($K_{e2γ}^{\rm SD^+}$) decay was investigated with stopped positive kaons. The $e^+$ momentum spectra containing 574$\pm$30 $K_{e2γ}^{\rm SD^+}$ events with a $K^+ \rightarrow μ^+ ν$ ($K_{\mu2}$) background of 28$\pm$19 events were measured with and without a photon in coincidence and analyzed with Monte Carlo simulations for acceptance and detector response to extract the ratio of the branching ratio of the $K_{e2γ}^{\rm SD^+}$ decay and the $K^+ \rightarrow e^+ ν$ decay including the internal bremsstrahlung process ($K_{e2(γ)}$). A value of $Br(K_{e2γ}^{\rm SD^+}) / Br(K_{e2(γ)}) = 1.12\pm0.07_{\rm stat} \pm 0.04_{\rm syst}$ was obtained. This indicates a partial branching ratio, $Br(K_{e2γ}^{\rm SD^+}, ~{p_e>200~{\rm MeV}/c}, ~{E_γ>10~{\rm MeV}})/Br(K_{\mu2}) =(1.85 \pm 0.11_{\rm{stat}} \pm 0.07_{\rm{syst}}) \times10^{-5}$, which is $25\%(\sim$2.5$σ)$ higher than the previous experimental result.

hep-ex

The design and basic performance of a Spiral Fiber Tracker for the J-PARC E36 experiment

A spiral fiber tracker (SFT) has been designed and produced for the J-PARC E36 experiment as an element of the tracking system for conducting a high-resolution momentum measurement of charge particles from kaon decays. A novel technique to wind the pre-made fiber ribbons spirally was employed for the configuration with four detector layers made of 1 mm diameter plastic scintillating fibers. Good position alignment and sufficiently high detection efficiency for charged particles with minimum ionizing energy were confirmed in cosmic ray test. The tracker was successfully used in the E36 experiment.