SearcharxivSearch

arXiv subjects

S. Posen

Publications and source records attributed to S. Posen.

At least 19 recordsLinked to original sources

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9\,GHz, we achieve continuous frequency tuning exceeding 1\,GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9\,mm, corresponding to a tuning range from 9.0 to 7.5\,GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

physics.ins-det

Detection of high-frequency gravitational waves using SRF cavities

Today, apart from some isolated R&D efforts, there are no gravitational wave (GW) experiments, yet which explore a large part of the vast frequency range above the LIGO/Virgo band. It is planned to establish an experiment at Deutsches Elektronen-Synchrotron (DESY) and at the Superconducting Quantum Materials and Systems (SQMS) Center at Fermi National Accelerator Laboratory (Fermilab) to search for high-frequency GWs in the frequency range of 10 kHz to 100 MHz. The basic idea is to use superconducting radiofrequency (SRF) cavities to detect tiny harmonic deformations induced by GWs which change the boundary conditions of the oscillating electromagnetic field. This paper summarizes the challenging environmental boundary requirements, and the R&D to operate a cavity using a low level RF (LLRF) system which pushes beyond state-of-the-art accuracy and resolutions and a seismic noise mitigated cryostat at 1.8 K. The focus of this paper is the warm and cold commissioning of a prototype cavity, built 20 years ago during the MAGO collaboration, and its first measurement in our collaborative research project.

physics.acc-ph

Superconducting Low-beta Nb$_3$Sn Cavity for ATLAS and Future Ion Accelerators

We report on a Nb$_3$Sn-coated low-beta superconducting radio frequency (SRF) cavity intended for accelerating ions. We aim to apply the cavity in ATLAS, our Argonne National Laboratory user facility for nuclear physics studies with ion beams in the energy range of 5-20 MeV/u. The Nb$_3$Sn-coated cavity, a 145 MHz quarter-wave optimized for ions moving with velocity $\beta$=v/c=0.08 exhibits an order-of-magnitude reduction in radiofrequency (RF) losses into helium at $4.4\,\mathrm{K}$ compared to a superconducting niobium (Nb) cavity at the same frequency and temperature. Experimentally measured fields are among the highest to date for any Nb$_3$Sn-coated cavity, reaching a peak surface magnetic field of 105 mT. We also present a practical solution to the problem of cavity frequency tuning. Tuning by mechanical deformation has been a challenge with Nb3Sn due to its brittle nature, however, using a set of techniques tailored to the properties of thin-film Nb$_3$Sn on Nb, we can repeatably tune the cavity to the ATLAS master clock frequency after it is cooled, while maintaining the excellent performance characteristics. The same Nb$_3$Sn cavity technology offers broad benefits for future ion accelerators.

physics.acc-ph

Testing of the 2.6 GHz SRF Cavity Tuner for the Dark Photon Experiment at 2 K

At FNAL two single cell 2.6 GHz SRF cavities are being used to search for dark photons, the experiment can be conducted at 2 K or in a dilution refrigerator. Precise frequency tuning is required for these two cavities so they can be matched in frequency. A cooling capacity constraint on the dilution refrigerator only allows piezo actuators to be part of the design of the 2.6 GHz cavity tuner. The tuner is equipped with three encapsulated piezos that deliver long and short-range frequency tuning. Modifications were implemented on the first tuner design due to the low forces on the piezos caused by the cavity. Three brass rods with Belleville washers were added to the design to increase the overall force on the piezos. The testing results at 2 K are presented with the original design tuner and with the modification.

physics.acc-ph

PI Loop Resonance Control for Dark Photon Experiment at 2 K Using a 2.6 GHz SRF Cavity

Two 2.6 GHz SRF cavities are being used for a dark photon search at the vertical test stand (VTS) in FNAL, for the second phase of the Dark SRF experiment. During testing at 2 K the cavities experience frequency detuning caused by microphonics and slow frequency drifts. The experiment requires that the two cavities have the same frequency within the cavity's bandwidth. These two cavities are equipped with frequency tuners consisting of three piezo actuators. The piezo actuators are used for fine-fast frequency tuning. A proportional-integral (PI) loop utilizing the three piezos on the emitter was used to stabilize the cavity frequency and match the receiver cavity frequency. The results from this implementation will be discussed. The integration time was also calculated via simulation.

physics.acc-ph

Demonstration of Niobium Tin in 218 MHz Low-beta Quarter Wave Accelerator Cavity

A 218 MHz quarter wave niobium cavity has been fabricated for the purpose of demonstrating Nb3Sn technology on a low-beta accelerator cavity. Niobiumtin has been established as a promising next generation SRF material, but development has focused primarily in high-beta elliptical cell cavities. This material has a significantly higher TC than niobium, allowing for design of higher frequency quarter wave cavities (that are subsequently smaller) as well as for significantly lowered cooling requirements (possibly leading to cryocooler based designs). The fabrication, initial cold testing, and Nb3Sn coating are discussed as well as test plans and details of future applications.

physics.acc-ph

Commissioning of Dedicated Furnace for Nb3Sn Coatings of 2.6 GHz Single Cell Cavities

We present the results of commissioning a dedicated furnace for Nb3Sn coatings of 2.6 GHz single cell cavities. Nb3Sn is a desired coating due to its high critical temperature and smaller surface resistance compared to bulk Nb. Usage of Nb3Sn coated cavities will greatly reduce operating costs due to decreased dependance on cryo cooling. Tin is deposited by use of a tin chloride nucleation agent and tin vapor diffusion. Analysis of the resultant coating was performed using SEM/EDS to verify successful formation of Nb3Sn. Witness samples in line of sight of the source were used in order to understand the coating efficacy.

physics.acc-ph

Preservation of the High Quality Factor and Accelerating Gradient of Nb3Sn-coated Cavity During Pair Assembly

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

physics.acc-ph

HELEN: Traveling Wave SRF Linear Collider Higgs Factory

Traveling wave SRF accelerating structures offer several advantages over the traditional standing wave structures: substantially lower $H_pk/E_acc$ and lower $E_pk/E_acc$, ratios of peak magnetic field and peak electric field to the accelerating gradient, respectively, together with substantially higher $R/Q$. In this paper we discuss how a linear collider Higgs Factory HELEN can be built using TW-based SRF linacs. We cover a plan to address technological challenges and describe ways to upgrade the collider luminosity and energy.

physics.acc-ph

Multipacting Processing in Cryomodules For LCLS-II And LCLS-II-HE

Multipacting (MP) is a phenomenon which can affect stability in particle accelerators and limit performance in superconducting radio frequency cavities. In the TESLA shaped, 1.3 GHz, 9-cell cavities used in the LCLS-II (L2) and LCLS-II-HE (HE) projects, the MP-band (~17-24 MV/m) lies within the required accelerating gradients. For HE, the operating gradient of 20.8 MV/m lies well within the MP-band and cryomodule testing has confirmed that this is an issue. As such, MP processing for the HE cryomodule test program will be discussed. Early results on MP processing in cryomodules installed in the L2 linac will also be presented, demonstrating that the methods used in cryomodule acceptance testing are also successful at conditioning MP in the accelerator and that this processing is preserved in the mid-term.

physics.acc-ph

An 8 GeV Linac as the Booster Replacement in the Fermilab Power Upgrade: a Snowmass 2021 White Paper

Following the PIP-II 800 MeV Linac, Fermilab will need an accelerator that extends from that linac to the MI injection energy of ~8 GeV, completing the modernization of the Fermilab high-intensity accelerator complex. This will maximize the beam available for neutrino production for the long baseline DUNE experiment to greater than 2.5 MW and enable a next generation of intensity frontier experiments. In this white paper, we propose an 8 GeV Linac for that purpose. The Linac consists of an extension of the PIP-II Linac to ~2 GeV using PIP-II 650 MHz SRF cryomodules, followed by a 2 -->8.0 GeV Linac composed of 1300 MHz SRF cryomodules, based upon the LCLS-II cryomodules developed at Fermilab. The 8 GeV Linac will incorporate recent improvements in SRF technology. The research needed to implement this Linac is described.

physics.acc-ph

New Exclusion Limit for Dark Photons from an SRF Cavity-Based Search (Dark SRF)

We conduct the first ``light-shining-through-wall" (LSW) search for dark photons using two state-of-the-art high quality-factor superconducting radio frequency (SRF) cavities and report the results of its pathfinder run. Our new experimental setup enables improvements in sensitivity over previous searches and covers new dark photon parameter space. We design delicate calibration and measurement protocols to utilize the high-$Q$ setup at Dark SRF. Using cavities operating at $1.3 \ \text{GHz}$, we establish a new exclusion limit for kinetic mixing as small as {$ε= 1.6\times 10^{-9}$} and provide the world's best constraints on dark photons in the $2.1\times 10^{-7} \ \text{eV} - 5.7\times10^{-6} \ \text{eV}$ mass range. Our result is the first proof-of-concept for the enabling role of SRF cavities in LSW setups, with ample opportunities for further improvements. In addition, our data sets a competitive lab-based limit on the Standard Model photon mass by searching for longitudinal photon polarization.

hep-ex

Measurement of high quality factor superconducting cavities in tesla-scale magnetic fields for dark matter searches

In dark matter searches using axion haloscopes, the search sensitivity depends on the quality factors ($Q_0$) of radiofrequency cavities immersed in multi-tesla magnetic fields. Increasing $Q_0$ would increase the scan rate through the parameter space of interest. Researchers developing superconducting radiofrequency cavities for particle accelerators have developed methods for obtaining extremely high $Q_0\sim10^{11}$ in $μ$T-scale magnetic fields. In this paper, we describe efforts to develop high Q cavities made from Nb$_3$Sn films using a technique developed for particle accelerator cavities. Geometry optimization for this application is explored, and two cavities are tested: an existing particle accelerator-style cavity and a geometry developed and fabricated for use in high fields. A quality factor of ($5.3\pm0.3$)$\times 10^5$ is obtained at 3.9~GHz and 6~T at 4.2~K.

physics.acc-ph

HELEN: A Linear Collider Based On Advanced SRF Technology

This paper discusses recently proposed Higgs Energy LEptoN (HELEN) $e+e-$ linear collider based on advances in superconducting radio frequency technology. The collider offers cost and AC power savings, smaller footprint (relative to the ILC), and could be built at Fermilab with an interaction region within the site boundaries. After the initial physics run at 250 GeV, the collider could be upgraded either to higher luminosity or to higher (up to 500 GeV) energies.

physics.acc-ph

200 MV Record Voltage Of vCM And LCLS-II-HE Cryomodules Production Start At Fermilab

The Linac Coherent Light Source (LCLS) is an X-ray science facility at SLAC National Accelerator Laboratory. The LCLS-II project (an upgrade to LCLS) is in the commissioning phase; the LCLS-II-HE (High Energy) project is another upgrade to the facility, enabling higher energy operation. An electron beam is accelerated using superconducting radio frequency (SRF) cavities built into cryomodules. It is planned to build 24 1.3 GHz standard cryomodules and one 1.3 GHz single-cavity Buncher Capture Cavity (BCC) cryomodule for the LCLS-II-HE project. Fourteen of these standard cryomodules and the BCC are planned to be assembled and tested at Fermilab. Procurements for standard cryomodule components are nearing completion. The first LCLS-II-HE cryomodule, referred to as the verification cryomodule (vCM) was assembled and tested at Fermilab. Fermilab has completed the assembly of the second cryomodule. This paper presents LCLS-II-HE cryomodule production status at Fermilab, emphasizing the changes done based on the successes, challenges, mitigations, and lessons learned from LCLS-II; validation of the changes with the excellent vCM results.

physics.acc-ph

An 8 GEV Linac As The Booster Replacement In The Fermilab Power Upgrade

Increasing the Fermilab Main Injector (MI) beam power above ~1.2 MW requires replacement of the 8 GeV Booster by a higher intensity alternative. Earlier, rapid-cycling synchrotron and linac solutions were considered for this purpose. In this paper, we consider the linac version that produces 8 GeV H- beam for injection into the Recycler Ring (RR) or MI The new linac takes ~1 GeV beam from the PIP-II linac and accelerates it to ~ 2 GeV in a 650 MHz SRF linac, and then accelerates to ~8 GeV in an SRF pulsed linac using 1300 MHz cryomodules. The linac components incorporate recent improvements in SRF technology. This Booster Replacement linac (BRL) will increase MI beam power to DUNE to more than 2.5 MW and enable next-generation intensity frontier experiments.

physics.acc-ph

Key directions for research and development of superconducting radio frequency cavities

Radio frequency superconductivity is a cornerstone technology for many future HEP particle accelerators and experiments from colliders to proton drivers for neutrino facilities to searches for dark matter. While the performance of superconducting RF (SRF) cavities has improved significantly over the last decades, and the SRF technology has enabled new applications, the proposed HEP facilities and experiments pose new challenges. To address these challenges, the field continues to generate new ideas and there seems to be a vast room for improvements. In this paper we discuss the key research directions that are aligned with and address the future HEP needs.

physics.acc-ph

LCLS-II and HE Cryomodule Microphonics at CMTF in Fermilab*

Microphonics causes the cavity to detune. This study discusses the microphonics of sixteen 1.3 GHz cryomodules, 14 for LCLS-II and 2 for LCLS-II HE tested at CMTF. The peak detuning, as well as the RMS detuning for each cryomodule, will be discussed. For each cryomodule, the data was taken with enough soaking time to prevent any thermalization effects which can show up in the detuning. Each data capture taken was 30 minutes or longer and sampled at 1 kHz.

physics.acc-ph