SearcharxivSearch

arXiv subjects

Satoshi Takashima

Publications and source records attributed to Satoshi Takashima.

11 recordsLinked to original sources

Low-Noise SiPM Light Readout and ASIC-Based Charge Readout of a Liquid Argon Time Projection Chamber for MeV Gamma-Ray Measurements

We have developed a compact liquid argon time projection chamber (LArTPC), NanoGRAMS, as a technology demonstrator for the Gamma-Ray and AntiMatter Survey (GRAMS). LArTPCs have the potential to enable Compton cameras with unprecedented effective area in the MeV gamma-ray band. NanoGRAMS has an active volume of $5.12 \times 5.12 \times 10~\mathrm{cm^3}$ and is equipped with a low-noise scintillation and charge readout system. The scintillation light is detected by an array of 16 SiPMs ($6 \times 6~\mathrm{mm^2}$ each), whose signals are summed and amplified by a low-noise transimpedance amplifier operable at liquid argon temperature. Ionization electrons are read out with $3.2\,\mathrm{mm}$-pitch pixels and processed by VATA-SGD ASICs, with synchronization provided by an FPGA-based data acquisition system. We irradiated the detector with a $^{60}\mathrm{Co}$ source (1173 and $1332\,\mathrm{keV}$) and successfully detected both 1-hit and 2-hit events. The collected charge was converted to deposited energy using a phenomenological recombination model, and the detector response was evaluated with a Geant4-based Monte Carlo simulation. The reconstructed energy spectrum shows Compton edges at 963 and $1118\,keV$, consistent with the expected values. For 2-hit events, the sequence of interactions was identified, and the reconstructed back-projection image agrees with the source position. These results demonstrate the feasibility of NanoGRAMS as a Compton camera for MeV gamma-ray imaging spectroscopy.

astro-ph.IM

X-ray Analysis and Photon-transport Simulations of SMC X-1: A Warped-disc Origin of the Superorbital Modulation

The luminous accreting pulsar SMC X-1 is an appropriate target to explore the accretion dynamics. SMC X-1 shows unique quasi-periodic flux variability of 40-65$\,$days known as superorbital modulation. To constrain the accretion structure of SMC X-1 based on timing and spectral study, we have analysed X-ray data of SMC X-1 observed by Suzaku and NuSTAR at various epochs between 2011 and 2022. The spectral analysis shows that the hydrogen column density ($N_\mathrm{H}$) increases from $1.1 \times 10^{22}\,\mathrm{cm^{-2}}$ to $1.24 \times 10^{23}\,\mathrm{cm^{-2}}$ as the flux decreases with the superorbital modulation. The neutral iron K$α$ line at 6.4$\,$keV has a broad width of 0.3$\,$keV, and its equivalent width increases as toward superorbital low states. The line broadening is consistent with Keplerian motion at the inner disc rather than the stellar wind velocity of the donor star. These findings support that the superorbital modulation is a consequence of X-ray attenuation by the warped accretion disc. To test this interpretation, we have conducted photon transport simulations of a system consisting of a neutron star, a warped disc, and optically-thin disc atmosphere. Occultation of the central source by the disc successfully reproduces the observed variations in the equivalent width of neutral iron K$α$ line, pulse profiles, and flux in hard X-rays. Notably, a disc precession angle of approximately $30^\circ$ can account for the observational features. For the radiation pattern of the photon source, the preferred beam width corresponds to a standard deviation of $30^\circ$.

astro-ph.HE

Development of Solar Flare X-ray Polarimeter with Micro-Pixel CMOS Sensors

We are developing an X-ray polarimeter using micro-pixel CMOS sensors for solar flare X-ray polarimetry. The system consists of a 2.5-$μ$m pixel CMOS image sensor with a 12.8$\times$12.8 mm$^2$ imaging area and a readout system based on a Zynq System-on-Chip. While previous studies have validated this concept, no realistic feasibility studies have been conducted for the solar flare X-ray polarization observation. In this work, we performed polarization sensitivity measurements at synchrotron facilities. The results show that our polarimeter is sensitive to the X-ray polarization, exhibiting a modulation factor of 5-15% at an energy range of 6-22 keV. The measurements also determined the thickness of the sensitive layer to be approximately 5 $μ$m, and the thicknesses of the insensitive layers to be 0.8 $μ$m (Si), 2.1 $μ$m (SiO2), and 0.24 $μ$m (Cu). These measured thicknesses lead to a quantum efficiency of 3-4% at 10 keV. Based on these experimental evaluations, we estimated the sensitivity of the micro-pixel CMOS polarimeter system. We found that, when combined with a telescope with an effective area of $\sim$10 cm$^2$, this system can detect X-ray polarization with a polarization degree of a few percent for M-class flares.

astro-ph.IM

The nature of spectral variability of the accreting pulsar Centaurus X-3 unveiled by NuSTAR observation covering two orbital cycles

We conducted a $369\;{\rm ks}$ NuSTAR observation on the X-ray pulsar Centaurus X-3, which covered two consecutive orbital cycles of the source, including two eclipse durations. We investigated the orbital-phase spectral variability over the two orbital cycles. We divided the entire observation data into multiple segments, each covering an orbital interval of $ΔΦ=0.005$. The phenomenological spectral modeling applied to these orbital-phase-resolved spectra reveals that the photon index is the key parameter with the most variability and a strong correlation with the continuum flux. The photon index becomes softer during the high-flux phases and harder in the low-flux phases. The relation between the photon index and continuum flux remains consistent when investigating specific spin phases, suggesting that the spectral variability originates from extrinsic factors apart from the neutron star. Furthermore, the 3-5 keV pulse fraction also exhibits variability, being enhanced in the high-flux phases and suppressed in the low-flux phases, which indicates the presence of multiple emission components with different pulse fractions. These phenomenological analysis results enabled us to estimate the physical origin of the spectral variability. We successfully fitted the orbital-phase-resolved spectra with a physical model that assumes (1) stable emission from the neutron star, (2) attenuation by inhomogeneous, clumpy stellar wind, and (3) an additional non-pulsed emission component arising from thermal emission from the accretion disk. The thermal emission from the accretion disk can be described by a blackbody with a temperature of $kT\sim0.5\;{\rm keV}$ and a luminosity of $\sim10^{37}\;{\rm erg\;s^{-1}}$.

astro-ph.HE

Imaging reconstruction method on X-ray data of CMOS polarimeter combined with coded aperture

X-ray polarization is a powerful tool for unveiling the anisotropic characteristics of high-energy celestial objects. We present a novel imaging reconstruction method designed for hard X-ray polarimeters employing a Si CMOS sensor and coded apertures, which function as a photoelectron tracker and imaging optics, respectively. Faced with challenges posed by substantial artifacts and background noise in the coded aperture imaging associated with the conventional balanced correlation method, we adopt the Expectation-Maximization (EM) algorithm as the foundation of our imaging reconstruction method. The newly developed imaging reconstruction method is validated with imaging polarimetry and a series of X-ray beam experiments. The method demonstrates the capability to accurately reproduce an extended source comprising multiple segments with distinct polarization degrees. Comparative analysis exhibits a significant enhancement in imaging reconstruction accuracy compared to the balanced correlation method, with the background noise levels reduced to 17%. The outcomes of this study enhance the feasibility of Cube-Sat imaging polarimetry missions in the hard X-ray band, as the combination of Si CMOS sensors and coded apertures is a promising approach for realizing it.

astro-ph.IM

Development of the X-ray polarimeter using CMOS imager: polarization sensitivity of a $1.5~{\rm μm}$ pixel CMOS sensor

We are developing an imaging polarimeter by combining a fine-pixel CMOS image sensor with a coded aperture mask as part of the cipher project, aiming to achieve X-ray polarimetry in the energy range of $10$$\unicode{x2013}$$30~\mathrm{keV}$. A successful proof-of-concept experiment was conducted using a fine-pixel CMOS sensor with a $2.5~\mathrm{μm}$ pixel size. In this study, we conducted beam experiments to assess the modulation factor (MF) of the CMOS sensor with a $1.5~\mathrm{μm}$ pixel size manufactured by Canon and to determine if there was any improvement in the MF. The measured MF was $8.32\% \pm 0.34\%$ at $10~\mathrm{keV}$ and $16.10\% \pm 0.68\%$ at $22~\mathrm{keV}$, exceeding those of the $2.5~\mathrm{μm}$ sensor in the $6$$\unicode{x2013}$$22~\mathrm{keV}$ range. We also evaluated the quantum efficiency of the sensor, inferring a detection layer thickness of $2.67 \pm 0.48~{\rm μm}$. To develop a more sensitive polarimeter, a sensor with a thicker detection layer, smaller pixel size, and reduced thermal diffusion effect is desirable.

astro-ph.IM

Orbital- and spin-phase variability in the X-ray emission from the accreting pulsar Cen X-3

We analyzed 39 ks NuSTAR observation data of the high mass X-ray binary Cen X-3 in order to investigate the orbital- and spin-phase spectral variability. The observation covers the orbital phase of $Φ=0.199$-$0.414$ of the source, where $Φ=0$ corresponds to the mid-eclipse. The orbital-phase-resolved spectroscopy revealed that low energy photons are more dominant for the spectral fluctuation, and a large part of the variability can be explained in terms of absorption by clumps of stellar wind. The spin-phase-resolved spectroscopy together with energy-resolved pulse profiles, on the other hand, presented large flux variations in high energy bands, which suggests that the origin of the variability is the different efficiency of Comptonization inside the accretion column. The energy band which includes Fe emission lines or cyclotron resonance scattering feature (CRSF) shows distinct variability compared to the nearby bands. The Fe lines show low variability along the spin phase, which indicates that the emission regions are apart from the neutron star. The central energy and strength of the CRSF are both positively correlated with the spin-phase-resolved flux, which suggests that the emitted photons face stronger magnetic fields and deeper absorption when they come from high-flux regions. We also examined the independence of the orbital- and spin-phase variability. They showed no correlation with each other and were highly independent, which implies the accretion stream is stable during the observation.

astro-ph.HE

Reconstruction of multiple Compton scattering events in MeV gamma-ray Compton telescopes towards GRAMS: the physics-based probabilistic model

Aimed at progress in mega-electron volt (MeV) gamma-ray astronomy, which has not yet been well-explored, Compton telescope missions with a variety of detector concepts have been proposed so far. One of the key techniques for these future missions is an event reconstruction algorithm that is able to determine the scattering orders of multiple Compton scattering events and to identify events in which gamma rays escape from the detectors before they deposit all of their energies. We revisit previous event reconstruction methods and propose a modified algorithm based on a probabilistic method. First, we present a general formalism of the probabilistic model of Compton scattering describing physical interactions inside the detector and measurement processes. Then, we also introduce several approximations in the calculation of the probability functions for efficient computation. For validation, the developed algorithm has been applied to simulation data of a Compton telescope using a liquid argon time projection chamber, which is a new type of Compton telescope proposed for the GRAMS project. We have confirmed that it works successfully for up to 8-hit events, including correction of incoming gamma-ray energies for escape events. The proposed algorithm can be used for next-generation MeV gamma-ray missions featured by large-volume detectors, e.g., GRAMS.

astro-ph.IM

Event reconstruction of Compton telescopes using a multi-task neural network

We have developed a neural network model to perform event reconstruction of Compton telescopes. This model reconstructs events that consist of three or more interactions in a detector. It is essential for Compton telescopes to determine the time order of the gamma-ray interactions and whether the incident photon deposits all energy in a detector or it escapes from the detector. Our model simultaneously predicts these two essential factors using a multi-task neural network with three hidden layers of fully connected nodes. For verification, we have conducted numerical experiments using Monte Carlo simulation, assuming a large-area Compton telescope using liquid argon to measure gamma rays with energies up to $3.0\,\mathrm{MeV}$. The reconstruction model shows excellent performance of event reconstruction for multiple scattering events that consist of up to eight hits. The accuracies of hit order prediction are around $60\%$ while those of escape flags are higher than $70\%$ for up to eight-hit events of $4π$ isotropic photons. Compared with two other algorithms, a classical model and a physics-based probabilistic one, the present neural network method shows high performance in estimation accuracy particularly when the number of scattering is small, 3 or 4. Since simulation data easily optimize the network model, the model can be flexibly applied to a wide variety of Compton telescopes.

astro-ph.IM

Snowmass 2021 Letter of Interest: The GRAMS Project: MeV Gamma-Ray Observations and Antimatter-Based Dark Matter Searches

The Gamma-Ray and AntiMatter Survey (GRAMS) project is a proposed next-generation balloon/satellite mission targeting both MeV gamma-ray observations and antimatter-based dark matter searches. A cost-effective, large-scale Liquid Argon Time Projection Chamber (LArTPC) detector technology will allow GRAMS to have a significantly improved sensitivity to MeV gamma rays while extensively probing dark matter parameter space via antimatter measurements.

astro-ph.HE

Artifact-less Coded Aperture Imaging in the X-ray Band with Multiple Different Random Patterns

The coded aperture imaging technique is a useful method of X-ray imaging in observational astrophysics. However, the presence of imaging noise or so-called artifacts in a decoded image is a drawback of this method. We propose a new coded aperture imaging method using multiple different random patterns for significantly reducing the image artifacts. This aperture mask contains multiple different patterns each of which generates a different artifact distribution in its decoded image. By summing all decoded images of the different patterns, the artifact distributions are cancelled out, and we obtain a remarkably accurate image. We demonstrate this concept with imaging experiments of a monochromatic 16 keV hard X-ray beam at the synchrotron photon facility SPring-8, using the combination of a CMOS image sensor and an aperture mask that has four different random patterns composed of holes with a diameter of 27 um and a separation of 39 um. The entire imaging system is installed in a 25 cm-long compact size, and achieves an angular resolution of < 30'' (full width at half maximum). In addition, we show by Monte Carlo simulation that the artifacts can be reduced more effectively if the number of different patterns increases to 8 or 16.

astro-ph.IM