arXiv · 2405.18907
Development of the X-ray polarimeter using CMOS imager: polarization sensitivity of a $1.5~{\rm \mu m}$ pixel CMOS sensor
Abstract
We are developing an imaging polarimeter by combining a fine-pixel CMOS image sensor with a coded aperture mask as part of the cipher project, aiming to achieve X-ray polarimetry in the energy range of $10$$\unicode{x2013}$$30~\mathrm{keV}$. A successful proof-of-concept experiment was conducted using a fine-pixel CMOS sensor with a $2.5~\mathrm{\mu m}$ pixel size. In this study, we conducted beam experiments to assess the modulation factor (MF) of the CMOS sensor with a $1.5~\mathrm{\mu m}$ pixel size manufactured by Canon and to determine if there was any improvement in the MF. The measured MF was $8.32\% \pm 0.34\%$ at $10~\mathrm{keV}$ and $16.10\% \pm 0.68\%$ at $22~\mathrm{keV}$, exceeding those of the $2.5~\mathrm{\mu m}$ sensor in the $6$$\unicode{x2013}$$22~\mathrm{keV}$ range. We also evaluated the quantum efficiency of the sensor, inferring a detection layer thickness of $2.67 \pm 0.48~{\rm \mu m}$. To develop a more sensitive polarimeter, a sensor with a thicker detection layer, smaller pixel size, and reduced thermal diffusion effect is desirable.
Explore related subjects
Keep this discovery
Toshiya Iwata, Kouichi Hagino, Hirokazu Odaka, Tsubasa Tamba, Masahiro Ichihashi, Tatsuaki Kato, Kota Ishiwata, Haruki Kuramoto, Hiroumi Matsuhashi, Shota Arai, Takahiro Minami, Satoshi Takashima, Aya Bamba. 2024-05-29. Development of the X-ray polarimeter using CMOS imager: polarization sensitivity of a $1.5~{\rm \mu m}$ pixel CMOS sensor. https://doi.org/10.1016/j.nima.2024.169487
Cite the original work for its findings. Save a collection to share your selection of sources.