SearcharxivSearch

arXiv subjects

Scott A. Hertel

Publications and source records attributed to Scott A. Hertel.

5 recordsLinked to original sources

Characterization of Aluminum Microwave SQUID Multiplexers for CE$ν$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($μ$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $μΦ_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $μΦ_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $μ$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $μΦ_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $μ$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

Low Energy Backgrounds and Excess Noise in a Two-Channel Low-Threshold Calorimeter

We describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a Transition Edge Sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: ``shared'' multichannel events with a pulse shape consistent with substrate athermal phonon events, and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These ``singles'' are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

physics.ins-det

A Stress Induced Source of Phonon Bursts and Quasiparticle Poisoning

The performance of superconducting qubits is degraded by a poorly characterized set of energy sources breaking the Cooper pairs responsible for superconductivity, creating a condition often called ``quasiparticle poisoning". Both superconducting qubits and low threshold dark matter calorimeters have observed excess bursts of quasiparticles or phonons that decrease in rate with time. Here, we show that a silicon crystal glued to its holder exhibits a rate of low-energy phonon events that is more than two orders of magnitude larger than in a functionally identical crystal suspended from its holder in a low-stress state. The excess phonon event rate in the glued crystal decreases with time since cooldown, consistent with a source of phonon bursts which contributes to quasiparticle poisoning in quantum circuits and the low-energy events observed in cryogenic calorimeters. We argue that relaxation of thermally induced stress between the glue and crystal is the source of these events.

physics.ins-det

Quantum Sensors for High Energy Physics

Strong motivation for investing in quantum sensing arises from the need to investigate phenomena that are very weakly coupled to the matter and fields well described by the Standard Model. These can be related to the problems of dark matter, dark sectors not necessarily related to dark matter (for example sterile neutrinos), dark energy and gravity, fundamental constants, and problems with the Standard Model itself including the Strong CP problem in QCD. Resulting experimental needs typically involve the measurement of very low energy impulses or low power periodic signals that are normally buried under large backgrounds. This report documents the findings of the 2023 Quantum Sensors for High Energy Physics workshop which identified enabling quantum information science technologies that could be utilized in future particle physics experiments, targeting high energy physics science goals.

hep-ex