SearcharxivSearch

arXiv subjects

Seok-Hyun Yun

Publications and source records attributed to Seok-Hyun Yun.

16 recordsLinked to original sources

Half-wave plasmonic nanolasers near the localization limit

Miniaturized lasers with sub-micron dimensions are of broad interest for optical science, on-chip communication, sensing, and biomedical barcoding. Recently, lowest-order half-wave lasing was demonstrated in semiconductor-on-metal cavities by operating away from the highly dispersive and absorptive surface-plasmon resonance. Here, we demonstrate half-wave-mode lasing near the surface-plasmon resonance at ~630 nm using high-gain indium phosphide (InP) nanoparticles on ultrasmooth gold substrates. The smallest lasing particle, estimated from simulated dispersion curves to have a length of ~115 nm and height of ~100 nm, emitted at 730 nm in air, representing one of the smallest reported active laser cavities. Linewidth and threshold pump fluence generally decreased as the lasing wavelength shifted farther from the plasmon resonance. In larger particles with lengths of 280~480 nm, we observed lasing attributable to second- and third-order plasmonic modes with progressively narrower linewidths. These results extend half-wave dipolar lasing toward near-infrared and visible wavelengths and further push laser miniaturization toward the plasmonic localization limit.

physics.optics

Optical Coherence Elastography Measures Mechanical Tension in the Lens and Capsule

Lens tension is essential for accommodative vision but remains difficult to measure with precision. Here, we present an optical coherence elastography (OCE) technique that quantifies both tension and elastic modulus in the lens capsule and underlying tissue. This method derives mechanical parameters from surface wave dispersion across a critical frequency range of 1-30 kHz. Using isolated lenses from six-month-old pigs, we measured intrinsic anterior capsular tensions of 0-20 kPa and posterior capsular tensions of 40-50 kPa, induced by intra-lenticular pressure at the cortical surface. The mean shear moduli of anterior and posterior capsules were 630 kPa and 400 kPa, respectively, nearly 100-fold greater than that of the cortical tissues, where tensions were below 1 kPa. Biaxial zonular stretching (~4% strain) increased anterior capsular tension by 67 kPa, with a low uncertainty of only 2 kPa. This optical method holds significant promise for diagnosing and managing accommodative dysfunctions through lens mechanics assessment in clinical settings.

physics.app-ph

Comprehensive characterization of nonlinear viscoelastic properties of arterial tissues using guided-wave optical coherence elastography

The mechanical properties of arterial walls are critical for maintaining vascular function under pulsatile pressure and are closely linked to the development of cardiovascular diseases. Despite advances in imaging and elastography, comprehensive characterization of the complex mechanical behavior of arterial tissues remains challenging. Here, we present a broadband guided-wave optical coherence elastography (OCE) technique, grounded in viscoelasto-acoustic theory, for quantifying the nonlinear viscoelastic, anisotropic, and layer-specific properties of arterial walls with high spatial and temporal resolution. Our results reveal a strong stretch dependence of arterial viscoelasticity, with increasing prestress leading to a reduction in tissue viscosity. Under mechanical loading, the adventitia becomes significantly stiffer than the media, attributable to engagement of collagen fibers. Chemical degradation of collagen fibers highlighted their role in nonlinear viscoelasticity. This study demonstrates the potential of OCE as a powerful tool for detailed profiling of vascular biomechanics, with applications in basic research and future clinical diagnosis.

physics.bio-ph

Air-Stable Room-Temperature Quasi-2D Tin Iodide Perovskite Microlasers

Quasi-2D tin iodide perovskites (TIPs) are promising lead-free alternatives for optoelectronic applications, but achieving stable lasing remains challenging due to their limited environmental stability. Here, we report air-stable, room-temperature lasing from quasi-2D TIP microcrystals as small as 4 μm. Incorporation of the organic spacer 5IPA3 significantly enhanced the stability of these materials compared to previously reported TIPs. Lasing was observed from both dielectric (n=4) and plasmonic (n=3 and n=4) TIP microlasers. Under picosecond pumping, lasing was sustained for over 10^8 pump pulses in ambient conditions. These results represent a significant step toward practical photonic applications of tin-based perovskites.

physics.optics

Incremental dynamics of prestressed viscoelastic solids and its applications in shear wave elastography

Shear wave elastography (SWE) is a promising imaging modality for mechanical characterization of tissues, offering biomarkers with potential for early and precise diagnosis. While various methods have been developed to extract mechanical parameters from shear wave characteristics, their relationships in viscoelastic materials under prestress remain poorly understood. Here, we present a generalized incremental dynamics theory for finite-strain viscoelastic solids. The theory derives small-amplitude viscoelastic wave motions in a material under static pre-stress. The formalism is compatible with a range of existing constitutive models, including both hyperelasticity and viscoelasticity--such as the combination of Gasser-Ogden-Holzapfel (GOH) and Kelvin-Voigt fractional derivative (KVFD) models used in this study. We validate the theory through experiments and numerical simulations on prestressed soft materials and biological tissues, using both optical coherence elastography and ultrasound elastography. The theoretical predictions closely match experimental dispersion curves over a broad frequency range and accurately capture the effect of prestress. Furthermore, the framework reveals the relationships among shear wave phase velocity, attenuation, and principal stresses, enabling prestress quantification in viscoelastic solids without prior knowledge of constitutive parameters. This generalized acousto-viscoelastic formalism is particularly well-suited for high-frequency, high-resolution SWE in tissues under prestress.

cond-mat.soft

Consensus Statement on Brillouin Light Scattering Microscopy of Biological Materials

Brillouin Light Scattering (BLS) spectroscopy is a non-invasive, non-contact, label-free optical technique that can provide information on the mechanical properties of a material on the sub-micron scale. Over the last decade it has seen increased applications in the life sciences, driven by the observed significance of mechanical properties in biological processes, the realization of more sensitive BLS spectrometers and its extension to an imaging modality. As with other spectroscopic techniques, BLS measurements not only detect signals characteristic of the investigated sample, but also of the experimental apparatus, and can be significantly affected by measurement conditions. The aim of this consensus statement is to improve the comparability of BLS studies by providing reporting recommendations for the measured parameters and detailing common artifacts. Given that most BLS studies of biological matter are still at proof-of-concept stages and use different--often self-built--spectrometers, a consensus statement is particularly timely to assure unified advancement.

physics.optics

Half-Wave Dipolar Metal-Semiconductor Laser

Nano-scale lasers harnessing metallic plasmons hold promise across physical sciences and industrial applications. Plasmons are categorized as surface plasmon polaritons (SPP) and localized surface plasmons (LSP). While SPP has gained popularity for nano-lasers by fitting a few cycles of SPP waves into resonators, achieving LSP lasing in single nanoparticles remains an elusive goal. Here, we highlight the equivalence of LSP and SPP within resonant systems and present lasers oscillating in the lowest-order LSP or, equivalently, half-cycle SPP. This diffraction-limited dipolar emitter is realized through strong coupling of plasmonic oscillation in gold and dielectric resonance in high-gain III-V semiconductor in the near infrared away from surface plasmon frequencies. The resulting single-mode stimulated emission peak exhibits linewidth Q factors over 50 at room temperature, with wide tunability spanning from 1190 to 1460 nm determined by resonator sizes ranging from 190 to 280 nm. A semiconductor laser model elucidates the temporal and spectral buildup dynamics under optical pumping. Notably, linewidth Q values surpassing 250 are attained from higher-order, isolated laser particles within live biological cells. These results offer fresh perspectives in nanophotonics and indicate promising opportunities for multiplexed biological applications.

physics.optics

Simultaneous tensile and shear measurement of the human cornea in vivo using S0- and A0-wave optical coherence elastography

Understanding corneal stiffness is valuable for improving refractive surgery, detecting corneal abnormalities, and assessing intraocular pressure. However, accurately measuring the elastic properties, particularly the tensile and shear moduli that govern mechanical deformation, has been challenging. To tackle this issue, we have developed guided-wave optical coherence elastography that can simultaneously excite and analyze symmetric (S0) and anti-symmetric (A0) elastic waves in the cornea at frequencies around 10 kHz and allows us to extract tensile and shear properties from measured wave dispersion curves. By applying acoustoelastic theory that incorporates corneal tension and a nonlinear constitutive tissue model, we verified the technique using elastomer phantoms and ex vivo porcine corneas and investigated the dependence on intraocular pressure. For two healthy human subjects, we measured a mean tensile modulus of 3.6 MPa and a mean shear modulus of 76 kPa in vivo with estimated errors of < 4%. This technique shows promise for the quantitative biomechanical assessment of the cornea in a clinical setting.

physics.med-ph

In vivo Optical Coherence Elastography Reveals Spatial Variation and Anisotropy of Corneal Stiffness

Objective: The mechanical properties of corneal tissues play a crucial role in determining corneal shape and have significant implications in vision care. This study aimed to address the challenge of obtaining accurate in vivo data for the human cornea. Methods: We have developed a high-frequency optical coherence elastography (OCE) technique using shear-like antisymmetric (A0)-mode Lamb waves at frequencies above 10 kHz. Results: By incorporating an anisotropic, nonlinear constitutive model and utilizing the acoustoelastic theory, we gained quantitative insights into the influence of corneal tension on wave speeds and elastic moduli. Our study revealed significant spatial variations in the shear modulus of the corneal stroma on healthy subjects for the first time. The central cornea exhibited a shear modulus of 74 kPa, while the corneal periphery showed a decrease to 41 kPa. The limbus demonstrated an increased shear modulus exceeding 100 kPa. We obtained wave displacement profiles that are consistent with highly anisotropic corneal tissues. Conclusion: Our approach enabled precise measurement of corneal tissue elastic moduli in situ with high precision (< 7%) and high spatial resolution (< 1 mm). Significance: The high-frequency OCE technique holds promise for biomechanical evaluation in clinical settings, providing valuable information for refractive surgeries, degenerative disorder diagnoses, and intraocular pressure assessments.

physics.med-ph

Ultrasmall InGa(As)P dielectric and plasmonic nanolasers

Nanolasers have great potential as both on-chip light sources and optical barcoding particles. We demonstrate ultrasmall InGaP and InGaAsP disk lasers with diameters down to 360 nm (198 nm in height) in the red spectral range. Optically pumped, room-temperature, single-mode lasing was achieved from both disk-on-pillar and isolated particles. When isolated disks were placed on gold, plasmon polariton lasing was obtained with Purcell-enhanced stimulated emission. UV lithography and plasma ashing enabled the fabrication of nanodisks on a wafer-scale, with intended random size variation. Silica-coated nanodisk particles generated stable sub-nanometer spectra from within biological cells across an 80 nm bandwidth from 635 to 715 nm.

physics.optics

Ultra-wideband optical coherence elastography from acoustic to ultrasonic frequencies

Visualizing elastic waves by noninvasive imaging has been useful for analyzing the mechanical properties of materials and tissues. However, the maximum wave frequency of elastography has been limited to ~10 kHz due to the finite sensitivity to small vibration and finite imaging speed. Here, we present an optical coherence elastography technique that extends the frequency range to MHz by noise reduction, anti-aliasing demodulation, and advanced wave analysis. Our system can measure the stiffness of hard (GPa) materials including bones with mm-scale resolution and characterize soft, viscoelastic materials from 100 Hz to 1 MHz. The dispersion of Rayleigh surface waves over the wide frequency range allowed us to profile depth-dependent shear modulus (10 kPa to 100 MPa) in cartilages ex vivo and the human skin in vivo. This technique opened a new window for the characterization of materials in situ with 3-dimensional resolution.

physics.app-ph

Measuring mechanical anisotropy of the cornea with Brillouin microscopy

Load-bearing tissues are typically fortified by networks of protein fibers, often with preferential orientations. This fiber structure imparts the tissues with direction-dependent mechanical properties optimized to support specific external loads. To accurately model and predict tissues' mechanical response, it is essential to characterize the anisotropy on a microstructural scale. Previously, it has been difficult to measure the mechanical properties of intact tissues noninvasively. Here, we use Brillouin optical microscopy to visualize and quantify the anisotropic mechanical properties of corneal tissues at different length scales. We derive the stiffness tensor for a lamellar network of collagen fibrils and use angle-resolved Brillouin measurements to determine the longitudinal stiffness coefficients (longitudinal moduli) describing the ex vivo porcine cornea as a transverse isotropic material. Lastly, we observe significant mechanical anisotropy of the human cornea in vivo, highlighting the potential for clinical applications of off-axis Brillouin microscopy.

physics.bio-ph

In vivo stiffness measurement of epidermis, dermis, and hypodermis using broadband Rayleigh-wave optical coherence elastography

Traveling-wave optical coherence elastography (OCE) is a promising technique to measure the stiffness of biological tissues. While OCE has been applied to relatively homogeneous samples, tissues with significantly varying elasticity through depth pose a challenge, requiring depth-resolved measurement with sufficient resolution and accuracy. Here, we develop a broadband Rayleigh-wave OCE technique capable of measuring the elastic moduli of the 3 major skin layers (epidermis, dermis, and hypodermis) reliably by analyzing the dispersion of leaky Rayleigh surface waves over a wide frequency range of 0.1-10 kHz. We show that a previously unexplored, high frequency range of 4-10 kHz is critical to resolve the thin epidermis, while a low frequency range of 0.2-1 kHz is adequate to probe the dermis and deeper hypodermis. We develop a dual bilayer-based inverse model to determine the elastic moduli in all 3 layers and verify its high accuracy with finite element analysis and skin-mimicking phantoms. Finally, the technique is applied to measure the forearm skin of healthy volunteers. The Young's modulus of the epidermis (including the stratum corneum) is measured to be ~ 4 MPa at 4-10 kHz, whereas Young's moduli of the dermis and hypodermis are about 40 and 15 kPa, respectively, at 0.2-1 kHz. Besides dermatologic applications, this method may be useful for the mechanical analysis of various other layered tissues with sub-mm depth resolution.

physics.med-ph

Non-destructive mapping of stress, strain and stiffness of thin elastically deformed materials

Knowing the stress within a soft material is of fundamental interest to basic research and practical applications, such as soft matter devices, biomaterial engineering, and medical sciences. However, it is challenging to measure stress fields in situ in a non-invasive way. It becomes even more difficult if the mechanical properties of the material are unknown or altered by the stress. Here we present a robust non-destructive technique capable of measuring in situ stress and strain in elastically deformed thin films without the need to know their material properties. The technique is based on measuring elastic wave speeds, and then using a universal dispersion curve we derived for Lamb wave to predict the local stress and strain. Using optical coherence tomography, we experimentally verified the method for a rubber sheet, a cling film, and the leather skin of a musical instrument.

cond-mat.soft

Supershear surface waves reveal prestress and anisotropy of soft materials

Surface waves play important roles in many fundamental and applied areas from seismic detection to material characterizations. Supershear surface waves with propagation speeds greater than bulk shear waves have recently been reported, but their properties are not well understood. In this Letter, we describe theoretical and experimental results on supershear surface waves in rubbery materials. We find that supershear surface waves can be supported in viscoelastic materials with no restriction on the shear quality factor. Interestingly, the effect of prestress on the speed of the supershear surface wave is opposite to that of the Rayleigh surface wave. Furthermore, anisotropy of material affects the supershear wave much more strongly than the Rayleigh surface wave. We offer heuristic interpretation as well as theoretical verification of our experimental observations. Our work points to the potential applications of supershear waves for characterizing the bulk mechanical properties of soft solid from the free surface.

cond-mat.soft

Spatially-resolved Brillouin spectroscopy reveals biomechanical changes in early ectatic corneal disease and post-crosslinking in vivo

Mounting evidence connects the biomechanical properties of tissues to the development of eye diseases such as keratoconus, a common disease in which the cornea thins and bulges into a conical shape. However, measuring biomechanical changes in vivo with sufficient sensitivity for disease detection has proved challenging. Here, we present a first large-scale study (~200 subjects, including normal and keratoconus patients) using Brillouin light-scattering microscopy to measure longitudinal modulus in corneal tissues with high sensitivity and spatial resolution. Our results in vivo provide evidence of biomechanical inhomogeneity at the onset of keratoconus and suggest that biomechanical asymmetry between the left and right eyes may presage disease development. We additionally measure the stiffening effect of corneal crosslinking treatment in vivo for the first time. Our results demonstrate the promise of Brillouin microscopy for diagnosis and treatment of keratoconus, and potentially other diseases.

q-bio.QM