Searcharxiv⌕ Search

arXiv subjects

Sergey P. Vyatchanin

Publications and source records attributed to Sergey P. Vyatchanin.

At least 19 recordsLinked to original sources

Dissipative coupling, dispersive coupling and their combination in the cavity-less opto-mechanical systems

The approach of variational measurement is applied to the cavity-less dissipative coupling (when test mass displacement is changing transmittance of a single mirror). The result obtained is compared to the cavity-less dispersive coupling (when the mass of displaced single mirror is changing the phase in reflected wave). These types of coupling are compared for ponderomotive squeezing. In addition, the cavity-less variant of combined dissipative and dispersive coupling is explored. It is established that combined coupling results in a stable optical rigidity even in case of a single pump. Finally, it is confirmed that variational measurement can be applied to combined coupling.

physics.ins-det↗

Optical entanglement facilitated by a hot mechanical oscillator

Optomechanical generation of entangled optical beams is usually hindered by thermal noise. We present a theoretical study of low frequency entanglement generation between two optical harmonics emitted from a cavity optomechanical system operating in the resolved-sideband regime. The system comprises three nearly equidistant optical modes in a high-finesse cavity, with the central mode coherently driven. This configuration enables radiation-pressure interactions that generate strong quantum correlations between the two sideband modes. Remarkably, these correlations persist even at large numbers of thermal quanta if one properly engineers the optical cooling rate of the mechanical mode. Our findings demonstrate the feasibility of robust entanglement under ambient conditions, opening new avenues for hybrid quantum technologies based on mechanical interfaces and continuous-variable quantum information processing.

quant-ph↗

Multimode Quantum Effects of Optical-Axis Misalignment in Gravitational-Wave Interferometers

We develop a multimode quantum model of optical-axis misalignment in a simplified representation of the differential mode of an Advanced LIGO interferometer. The system is described as two coupled optical resonators corresponding to the signal extraction cavity and the arm cavity. Analytical expressions for the mode-mixing coefficients are derived, establishing a direct connection between geometrical perturbations of optical elements and multimode optical dynamics. Using the developed formalism, we investigate the influence of optical-axis misalignment on quantum-noise-limited sensitivity and injected squeezed states. We show that misalignment between the signal extraction cavity and the arm cavity leads to significant sensitivity degradation, frequency-dependent rotation of the squeezing ellipse, and a reduction of the observable squeezing in the fundamental spatial mode. At the same time, the injected squeezing is not destroyed but redistributed among coupled spatial modes. The resulting mode coupling generates quantum correlations between the fundamental and higher-order modes and leads to spatial-mode entanglement verified using the positive partial transpose criterion. Our results demonstrate that optical-axis misalignment should be treated as a coherent multimode quantum process rather than as a simple optical loss mechanism.

physics.optics↗

Broadband Multidimensional Variational Measurement with Non-Symmetric Coupling

A broadband multidimensional variational measurement allows overcoming the Standard Quantum Limit (SQL) of a classical mechanical force detection for a mechanical oscillator. In this measurement quantum back action, which perturbs the evolution of a mechanical oscillator, can be completely removed in a broad detection frequency band after post-processing. The measurement is performed by optical pumping of the central optical mode and analyzing the light escaping the two other optical modes, which have the frequency separation with the central mode equal to the mechanical frequency. To realize such a scheme in practice one either needs to use a very long optical interferometer or should utilize optical modes belonging to different mode families. In the second case the modes have different geometries and their coupling with the mechanical mode is not identical. Here we analyze a general case of the non-symmetric measurement scheme, in which the coupling strengths with the light modes are not equal to each other, and take into account optical losses. We found that the back action can be completely excluded from the measurement result in the case of the asymmetric lossless system. The nonzero loss limits the sensitivity. An experimental implementation of the proposed scheme is discussed.

quant-ph↗

Squeezing for Broadband Multidimensional Variational Measurement

Broadband multidimensional variational measurement allows to overcome Standard Quantum Limit (SQL) of a classical mechanical force detection, resulting from quantum back action, which perturbs evolution of a mechanical oscillator. In this optomechanic scheme detection of a resonant signal force acting on a linear mechanical oscillator coupled to a system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pumping of the central optical mode and measuring the light escaping the two other modes. Detection of optimal quadrature components of the optical modes and post processing result in the back action exclusion in a broad frequency band and surpassing SQL. We show that optical losses inside cavity restrict back action exclusion due to loss noise. We also analyze how two-photon (nondegenerate) and conventional (degenerate) squeezing improve sensitivity with account optical losses, considering mainly internal squeezing.

quant-ph↗

Enhanced optomechanical interaction in the unbalanced interferometer

Quantum optomechanical systems enable the study of fundamental questions on quantum nature of massive objects. For that a strong coupling between light and mechanical motion is required, which presents a challenge for massive objects. In particular large interferometric sensors with low frequency oscillators are difficult to bring into quantum regime. Here we propose a modification of the Michelson-Sagnac interferometer, which allows to boost the optomechanical coupling strength. This is done by unbalancing the central beam-splitter of the interferometer, allowing to balance two types of optomechanical coupling present in the system: dissipative and dispersive. We analyse two different configurations, when the optomechanical cavity is formed by the mirror for the laser pump field (power-recycling), and by the mirror for the signal field (signal-recycling). We show that the imbalance of the beam splitter allows to dramatically increase the optical cooling of the test mass motion. We also formulate the conditions for observing quantum radiation-pressure noise and ponderomotive squeezing. Our configuration can serve as the basis for more complex modifications of the interferometer that would utilize the enhanced coupling strength. This will allow to efficiently reach quantum state of large test masses, opening the way to studying fundamental aspects of quantum mechanics and experimental search for quantum gravity.

quant-ph↗

Broadband Coherent Multidimensional Variational Measurement

Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action perturbing evolution of a mechanical system. In this paper we show that usage of a multidimensional optical transducer may enable a broadband quantum back action evading measurement. We study a corresponding technique for measurement of a resonant signal force acting on a linear mechanical oscillator coupled to an optical system with three optical modes with separation nearly equal to the mechanical frequency. The measurement is performed by optical pumping of the central optical mode and measuring the light escaping the two other modes. By detecting optimal quadrature components of the optical modes and post-processing the measurement results we are able to exclude the back action in a broad frequency band and characterize the force with sensitivity better than SQL. We discuss how proposed scheme relates to multidimensional system containing quantum-mechanics-free subsystems (QMFS) which can evade the SQL using idea of so called "negative mass".

quant-ph↗

Combination of dissipative and dispersive coupling in the cavity optomechanical systems

An analysis is given for the Fabry-Perot cavity having a combination of dissipative and dispersive optomechanical coupling. It is established that the combined coupling leads to optical rigidity. At the same time, this rigidity appears in systems with the combined coupling on the resonant pump, which is not typical for pure dispersive and dissipative couplings. A proposal is made to use this system to detect small signal forces with better sensitivity than SQL. It is also demonstrated that this optomechanical system can create ponderomotive squeezing with controllable parameters over a wider range than ponderomotive squeezing using dispersive coupling.

quant-ph↗

Broadband Back Action Cancellation in a Dichromatic Variational Measurement

Quantum back action imposes fundamental sensitivity limits to the majority of quantum measurements. The effect results from the unavoidable contamination of the measured parameter with the quantum noise of a meter. Back action evading measurements take advantage of the quantum correlations introduced by the system under study to the meter and allow overcoming the fundamental limitations. The measurements are frequently restricted in their bandwidth due to a finite response time of the system components. Here we show that probing a mechanical oscillator with a dichromatic field with frequencies separated by the oscillator frequency enables independent detection and complete subtraction of the measurement noise associated with the quantum back action.

quant-ph↗

Broadband Dichromatic Variational Measurement

Standard Quantum Limit (SQL) of a classical mechanical force detection results from quantum back action impinged by the meter on a probe mechanical transducer perturbed by the force of interest. In this paper we introduce a technique of continuous \vy{broadband} back action avoiding measurements for the case of a resonant signal force acting on a linear mechanical oscillator supporting one of mirrors of an optical Michelson-Sagnac Interferometer (MSI). The interferometer with the movable mirror is an opto-mechanical transducer able to support polychromatic probe field. The method involves a dichromatic optical probe resonant with the MSI modes and having frequency separation equal to the mechanical frequency. We show that analyzing each of the harmonics of the probe reflected from the mechanical system separately and postprocessing the measurement results allows excluding the back action in a broad frequency band and measuring the force with sensitivity better than SQL.

quant-ph↗

Diffraction losses of a Fabry-Perot cavity with nonidentical non-spherical mirrors

Optical cavities with both optimized resonant conditions and high quality factors are important metrological tools. In particular, they are used for laser gravitational wave (GW) detectors. It is necessary to suppress the parametric instability by damping the resonant conditions of harmful higher order optical modes (HOOM) in order to have high cavity powers in GW detectors. This can be achieved effectively by using non spherical mirrors in symmetric Fabry-Perot (FP) cavities by increasing roundtrip losses of HOOMs. Fabry-Perot cavities in most of the GW detectors have non-identical mirrors to optimize clipping losses and reduce thermal noise by reducing the beam size on one side of the cavity facing to the beam splitter and recycling cavities. We here present a general method to design non spherical non-identical mirrors in non-symmetric FP cavities to damp HOOMs. The proposed design allows to the suppress the loss of the arm power caused by point absorbers on test masses.

physics.optics↗

Polarization loss in reflecting coating

In laser gravitational waves detectors optical loss restricts sensitivity. We discuss polarization scattering as one more possible mechanism of optical losses. Circulated inside interferometer light is polarized and after reflection its plane of polarization can turn a little due to reflecting coating of mirror can have slightly different refraction index along axes $x,\, y$ in plane of mirror surface (optical anisotropy). This anisotropy can be produced during manufacture of coating (elasto-optic effect). This orthogonal polarized light, enhanced in cavity, produces polarization optical loss. Polarization map of mirrors is very important and we propose to measure it. Polarization loss can be important in different precision optical experiments based on usage of polarized light, for example, in quantum speed meter.

astro-ph.IM↗

Stable Optical Rigidity Based on Dissipative Coupling

We show that the stable optical rigidity can be obtained in a Fabry-Perot cavity with dissipative optomechanical coupling and with detuned pump, corresponding conditions are formulated. An optical detection of a weak classical mechanical force with usage of this rigidity is analyzed. The sensitivity of small force measurement can be better than the standard quantum limit (SQL).

quant-ph↗

Gyroscope as quantum angular speed meter

We found that the measurement sensitivity of an optical integrating gyroscope is fundamentally limited due to ponderomotive action of the light leading to the standard quantum limit of the rotation angle detection. The uncorrelated quantum fluctuations of power of clockwise and counterclockwise electromagnetic waves result in optical power-dependent uncertainty of the angular gyroscope position. We also show that, on the other hand, a quantum back action evading measurement of angular momentum of a gyroscope becomes feasible if proper measurement strategy is selected. The angle is perturbed in this case. This observation hints on fundamental inequivalency of integrating and rate gyroscopes.

physics.optics↗

Electromagnetic Continuum Induced Nonlinearity

A nonrelativistic Hamiltonian describing interaction between a mechanical degree of freedom and radiation pressure is commonly used as an ultimate tool for studying system behavior in opto-mechanics. This Hamiltonian is derived from the equation of motion of a mechanical degree of freedom and the optical wave equation with time-varying boundary conditions. We show that this approach is deficient for studying higher order nonlinear effects in an open resonant opto-mechanical system. Opto-mechanical interaction induces a large mechanical nonlinearity resulting from a strong dependence of the power of the light confined in the optical cavity on the mechanical degrees of freedom of the cavity due to coupling with electromagnetic continuum. This dissipative nonlinearity cannot be inferred from the standard Hamiltonian formalism.

physics.optics↗

On fundamental diffraction limitation of finesse of a Fabry-Perot cavity

We perform a theoretical study of finesse limitations of a Fabry-Perot (FP) cavity occurring due to finite size, asymmetry, as well as imperfections of the cavity mirrors. A method of numerical simulations of the eigenvalue problem applicable for both the fundamental and high order cavity modes is suggested. Using this technique we find spatial profile of the modes and their round-trip diffraction loss. The results of the numerical simulations and analytical calculations are nearly identical when we consider a conventional FP cavity. The proposed numerical technique has much broader applicability range and is valid for any FP cavity with arbitrary non-spherical mirrors which have cylindrical symmetry but disturbed in an asymmetric way, for example, by tilt or roughness of their mirrors.

physics.optics↗

On sensitivity limitations of a dichromatic optical detection of a classical mechanical force

We apply the strategy of the back action evading measurement of a quadrature component of mechanical motion of a test mass to detection of a classical force acting on the mass (Science, 209, (1980) 547) and study both classical and quantum limitations of the technique. We are considering a resonant displacement transducer interrogated with a dichromatic optical pump as a model system in this study. The transducer is represented by a Fabry Perot cavity with a totally reflecting movable end mirror the resonant force of interest acts upon. The cavity is pumped with two coherent optical carriers equally detuned from one of the cavity resonances. We show that the quantum back action cannot be completely excluded from the measurement result due to the dynamic instability of the opto-mechanical system that either limits the allowable power of the optical pump or calls for introducing an asymmetry to the pump configuration destroying the quantum nondemolition nature of the measurement.

quant-ph↗

Optical Gravitational Wave Antenna with Increased Power Handling Capability

Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose to optimize geometrical shape of the mirrors of the detector to reduce the diffraction-limited finesse of unessential optical modes of the interferometer resulting in increase of the threshold of the opto-mechanical instabilities and subsequent increase of the measurement sensitivity. Utilizing parameters of the LIGO interferometer we found that the proposed technique allows constructing a Fabry-Perot interferometer with round trip diffraction loss of the fundamental mode not exceeding $5$~ppm, whereas the loss of the first dipole as well as the other high order modes exceed $1,000$~ppm and $8,000$~ppm, respectively. The optimization comes at the price of tighter tolerances on the mirror tilt stability, but does not result in a significant modification of the optical beam profile and does not require changes in the the gravity detector read-out system. The cavity with proposed mirrors is also stable with respect to the slight modification of the mirror shape.

gr-qc↗