Searcharxiv⌕ Search

arXiv subjects

Sergey P. Vyatchanin

Publications and source records attributed to Sergey P. Vyatchanin.

34 records · Page 2Linked to original sources

Time evolution of parametric instability in large-scale gravitational-wave interferometers

We present a study of three-mode parametric instability in large-scale gravitational-wave detectors. Previous work used a linearised model to study the onset of instability. This paper presents a non-linear study of this phenomenon, which shows that the initial stage of exponential rise of the amplitudes of a higher order optical mode and the mechanical internal mode of the mirror is followed by a saturation phase, in which all three participating modes reach a new equilibrium state with constant oscillation amplitudes. Results suggest that stable operation of interferometers may be possible in the presence of such instabilities, thereby simplifying the task of suppression.

gr-qc↗

On limitation of quality factor of single mode resonators with finite size

Using realistic numerical models we analyze radiative loss of bound and unbound modes of specially designed high-Q whispering gallery and Fabry-Perot cavities of similar size and shape, and find a set of parameters when they can be treated as single mode structures. We show that these cavities have similar properties in spite of their different loss mechanisms. The cavity morphology engineering does not lead to reduction of the resonator quality factor.

physics.optics↗

Squeezing of optomechanical modes in detuned Fabry-Perot interferometer

We carry out analysis of optomechanical system formed by moveable mirror of Fabry-Perot cavity pumped by detuned laser. Optical spring arising from detuned pump creates in the system several eigen modes which could be treated as high-Q oscillators. Modulation of laser power results in parametric modulation of oscillators spring constants thus allowing to squeeze noise in quadratures of the modes. Evidence of the squeezing could be found in the light reflected from the cavity.

quant-ph↗

Calculation of thermal noise in grating reflectors

Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed 3rd generation gravitational wave detector. Depending on the grating geometry, the grating material and the temperature we obtain a thermal noise decrease by up to a factor of ten compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.

gr-qc↗

Observation of Three-Mode Parametric Instability

Three-mode parametric interactions can occur in triply-resonant opto-mechanical systems in which two orthogonal optical modes are coupled with an appropriate mechanical mode. Using an optical cavity with a membrane inside, we report the first observation of three-mode parametric instability in a Fabry-Perot cavity, a phenomenon predicted to occur in long baseline advanced gravitational wave detectors. We present a large signal model for the phenomenon, which predicts exponential growth of mechanical oscillation followed by saturation. Our experimental results are consistent with this model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques in Advanced gravitational wave detectors.

physics.optics↗

Back action cancellation in resolved sideband regime

We consider the simple model of measurement of mechanical oscillator position via Fabry-Pero cavity pumped by detuned laser (end mirror of cavity is mass of oscillator) in resolved sideband regime when laser is detuned from cavity's frequency by frequency of mechanical oscillator $\pmω_m$ and relaxation rate $γ$ of cavity is small: $γ\ll ω_m$. We demonstrate fluctuation back action cancellation in reflected wave. However, it does not allow to circumvent Standard Quantum Limit, the reason of it is the dynamic back action.

quant-ph↗

Sensitivity of laser gravitational-wave detectors with stable double-pumped optical spring

We analyze the sensitivity of gravitational-wave antenna with stable double optical spring created by two independent pumps. We investigate regime of three close eigen frequencies (roots of characteristic equation) which appears to provide more wide frequency band in which sensitivity of antenna can beat Standard Quantum Limit (SQL) than previously considered regime with two close eigen frequencies. We take into account optical losses and show that they do not degrade sensitivity significantly. We also demonstrate possible application of considered regime to Einstein Telescope.

gr-qc↗

Reducing Thermal Noise in Future Gravitational Wave Detectors by employing Khalili Etalons

Reduction of thermal noise in dielectric mirror coatings is a key issue for the sensitivity improvement in second and third generation interferometric gravitational wave detectors. Replacing an end mirror of the interferometer by an anti-resonant cavity (a so-called Khalili cavity) has been proposed to realize the reduction of the overall thermal noise level. In this article we show that the use of a Khalili etalon, which requires less hardware than a Khalili cavity, yields still a significant reduction of thermal noise. We identify the optimum distribution of coating layers on the front and rear surfaces of the etalon and compare the total noise budget with a conventional mirror. In addition we briefly discuss advantages and disadvantages of the Khalili etalon compared with the Khalili cavity in terms of technical aspects, such as interferometric length control and thermal lensing.

gr-qc↗

Reduction of coating thermal noise by using an etalon

Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of quarter-wavelength dielectric layers to achieve high reflectivity while the thermal-noise level increases with the number of layers. One way to realize the reduction of coating thermal noise, recently proposed by Khalili, is the mechanical separation of the first few layers from the rest so that a major part of the fluctuations contributes only little to the phase shift of the reflected light. Using an etalon, a Fabry-Perot optical resonator of a monolithic cavity, with a few coating layers on the front and significantly more on the back surface is a way to realize such a system without too much complexity, and in this paper we perform a thermal-noise analysis of an etalon using the Fluctuation-dissipation theorem with probes on both sides of a finite-size cylindrical mirror.

gr-qc↗

Double Michelson/Fabry-Perot interferometer for laser- and displacement-noise-free gravitational-wave detection

In this paper we demonstrate that a double Michelson interferometer with Fabry-Perot cavities in its arms is able to perform laser- and displacement-noise-free gravitational-wave (GW) detection if certain model assumptions are met. Assuming the input mirrors of a single Michelson/Fabry-Perot interferometer can be rigidly attached to beamsplitter on a central platform one can manipulate with interferometer's response signals in a way to cancel laser noise and displacement noise of all test masses except the cental platform. A pair of symmetrically positioned Michelson/Fabry-Perot interferometers with common central platform can be made insusceptible to the later then, thus allowing complete laser- and displacement-noise-free interferometry (DFI). It is demonstrated that the DFI response to GWs of the proposed interferometer is proportional to $f^2_{\textrm{gw}}/γ$, where $γ$ is the cavity half-bandwidth, that is the strongest DFI response allowed by general relativity.

gr-qc↗

Displacement- and laser-noise-free gravitational-wave detection with two Fabry-Perot cavities

We propose two Fabry-Perot cavities, each pumped through both the mirrors, positioned in line as a toy model of the gravitational-wave (GW) detector free from displacement noise of the test masses. It is demonstrated that the displacement noise of cavity mirrors as well as laser noise can be completely excluded in a proper linear combination of the cavities output signals. We show that in low-frequency approximation (gravitational wave length $λ-\text{gw}$ is much greater than distance $L$ between mirrors $λ_\text{gw}\gg L$) the decrease of response signal is about $(L/λ_\text{gw})^2$, i.e. signal is stronger than the one of the interferometer recently proposed by S. Kawamura and Y. Chen.

gr-qc↗

Displacement-noise-free gravitational-wave detection with a single Fabry-Perot cavity: a toy model

We propose a detuned Fabry-Perot cavity, pumped through both the mirrors, as \textit{a toy model} of the gravitational-wave (GW) detector partially free from displacement noise of the test masses. It is demonstrated that the noise of cavity mirrors can be eliminated, but the one of lasers and detectors cannot. The isolation of the GW signal from displacement noise of the mirrors is achieved in a proper linear combination of the cavity output signals. The construction of such a linear combination is possible due to the difference between the reflected and transmitted output signals of detuned cavity. We demonstrate that in low-frequency region the obtained displacement-noise-free response signal is much stronger than the $f^3_{\textrm{gw}}$-limited sensitivity of displacement-noise-free interferometers recently proposed by S. Kawamura and Y. Chen. However, the loss of the resonant gain in the noise cancelation procedure results is the sensitivity limitation of our toy model by displacement noise of lasers and detectors.

gr-qc↗

Displacement-noise-free resonant speed meter for gravitational-wave detection

We demonstrate that speedmeter, based on double pumped resonant Sagnac interferometer, can be used as a displacement noise free gravitational-wave (GW) detector. The displacement noise of cavity mirrors can be completely excluded through a proper linear combination of the output signals. We show that in low-frequency region the obtained displacement-noise-free response signal is stronger than the one in previously proposed displacement noise free interferometers.

gr-qc↗

Displacement-noise-free gravitational-wave detection with two Fabry-Perot cavities

We propose two detuned Fabry-Perot cavities, each pumped through both the mirrors, positioned in line as a toy model of the gravitational-wave (GW) detector free from displacement noise of the test masses. It is demonstrated that the noise of cavity mirrors can be completely excluded in a proper linear combination of the cavities output signals. This model is illustrated by a simplified round trip model (without Fabry-Perot cavities). We show that in low-frequency region the obtained displacement-noise-free response signal is stronger than the one of the interferometer recently proposed by S.Kawamura and Y.Chen.

gr-qc↗

The noise in gravitational-wave detectors and other classical-force measurements is not influenced by test-mass quantization

It is shown that photon shot noise and radiation-pressure back-action noise are the sole forms of quantum noise in interferometric gravitational wave detectors that operate near or below the standard quantum limit, if one filters the interferometer output appropriately. No additional noise arises from the test masses' initial quantum state or from reduction of the test-mass state due to measurement of the interferometer output or from the uncertainty principle associated with the test-mass state. Two features of interferometers are central to these conclusions: (i) The interferometer output (the photon number flux N(t) entering the final photodetector) commutes with itself at different times in the Heisenberg Picture, [N(t), N(t')] = 0, and thus can be regarded as classical. (ii) This number flux is linear in the test-mass initial position and momentum operators x_o and p_o, and those operators influence the measured photon flux N(t) in manners that can easily be removed by filtering -- e.g., in most interferometers, by discarding data near the test masses' 1 Hz swinging freqency. The test-mass operators x_o and p_o contained in the unfiltered output N(t) make a nonzero contribution to the commutator [N(t), N(t')]. That contribution is cancelled by a nonzero commutation of the photon shot noise and radiation-pressure noise, which also are contained in N(t). This cancellation of commutators is responsible for the fact that it is possible to derive an interferometer's standard quantum limit from test-mass considerations, and independently from photon-noise considerations. These conclusions are true for a far wider class of measurements than just gravitational-wave interferometers. To elucidate them, this paper presents a series of idealized thought experiments that are free from the complexities of real measuring systems.

gr-qc↗

Conversion of conventional gravitational-wave interferometers into QND interferometers by modifying their input and/or output optics

The LIGO-II gravitational-wave interferometers (ca. 2006--2008) are designed to have sensitivities at about the standard quantum limit (SQL) near 100 Hz. This paper describes and analyzes possible designs for subsequent, LIGO-III interferometers that can beat the SQL. These designs are identical to a conventional broad-band interferometer (without signal recycling), except for new input and/or output optics. Three designs are analyzed: (i) a "squeezed-input interferometer" (conceived by Unruh based on earlier work of Caves) in which squeezed vacuum with frequency-dependent (FD) squeeze angle is injected into the interferometer's dark port; (ii) a "variational-output" interferometer (conceived in a different form by Vyatchanin, Matsko and Zubova), in which homodyne detection with FD homodyne phase is performed on the output light; and (iii) a "squeezed-variational interferometer" with squeezed input and FD-homodyne output. It is shown that the FD squeezed-input light can be produced by sending ordinary squeezed light through two successive Fabry-Perot filter cavities before injection into the interferometer, and FD-homodyne detection can be achieved by sending the output light through two filter cavities before ordinary homodyne detection. With anticipated technology and with laser powers comparable to that planned for LIGO-II, these interferometers can beat the amplitude SQL by factors in the range from 3 to 5, corresponding to event rate increases between ~30 and ~100 over the rate for a SQL-limited interferometer.

gr-qc↗