Searcharxiv⌕ Search

arXiv subjects

Shaobo Wang

Publications and source records attributed to Shaobo Wang.

At least 73 records · Page 4Linked to original sources

Reasoning Like an Economist: Post-Training on Economic Problems Induces Strategic Generalization in LLMs

Directly training Large Language Models (LLMs) for Multi-Agent Systems (MAS) remains challenging due to intricate reward modeling, dynamic agent interactions, and demanding generalization requirements. This paper explores whether post-training techniques, specifically Supervised Fine-Tuning (SFT) and Reinforcement Learning with Verifiable Rewards (RLVR), can effectively $\textit{generalize}$ to multi-agent scenarios. We use economic reasoning as a testbed, leveraging its strong foundations in mathematics and game theory, its demand for structured analytical reasoning, and its relevance to real-world applications such as market design, resource allocation, and policy analysis. We introduce $\textbf{Recon}$ ($\textbf{R}$easoning like an $\textbf{ECON}$omist), a 7B-parameter open-source LLM post-trained on a hand-curated dataset of 2,100 high-quality economic reasoning problems. Comprehensive evaluation on economic reasoning benchmarks and multi-agent games reveals clear improvements in structured reasoning and economic rationality. These results underscore the promise of domain-aligned post-training for enhancing reasoning and agent alignment, shedding light on the roles of SFT and RL in shaping model behavior. Code is available at https://github.com/MasterZhou1/Recon .

cs.AI↗

Characterization of a gaseous time projection chamber with an internal \ce{^{37}Ar} source

We report on a novel calibration method of gaseous detectors using an internal \ce{^{37}Ar} source. The \ce{^{37}Ar} is a fast-decaying and low-energy calibration source that provides a mono-energetic peak of 2.82 keV. A gaseous \ce{^{37}Ar} source is injected and uniformly distributed in a Micromegas-based gaseous time projection chamber (TPC). Key performance parameters of the detector, such as electron transmission, gain, energy resolution, gain uniformity, and drift field evolution, are effectively and quickly calibrated. The gain uniformity, related to the homogeneity of the avalanche gap of Micromegas, is calibrated quickly thanks to the event-by-event position reconstruction and quasi-point energy deposition of \ce{^{37}Ar}. The energy resolution is improved with the obtained gain uniformity map. The most noticeable improvement in energy resolution, from 44.9\% to 35.4\%, is observed at a working pressure of 7 bar. The internal calibration source is also used to characterize the dependence of the detector's electric field distortion on the drift field.

physics.ins-det↗

Measurement of two-neutrino double electron capture half-life of $^{124}$Xe with PandaX-4T

Detailed studies of two-neutrino double electron capture (2$ν$DEC) is a crucial step towards searching for the neutrino-less mode to explore the Majorana nature of neutrinos. We have measured precisely the half-life of the 2$ν$DEC process in $^{124}$Xe, utilizing a total exposure of 1.73 tonne$\cdot$year from the commissioning run and the first science run of the PandaX-4T experiment. A time-dependent background model in the $\mathcal{O}$(10 keV) energy is constructed for the first time in PandaX-4T data. With an unbinned maximum likelihood fit, we determine the half-life of the 2$ν$DEC process to be $(1.03\pm0.15_{\rm stat}\pm0.08_{\rm sys})\times 10^{22}$$\,$yr. Furthermore, we have evaluated the branching ratio for both electrons captured from the $K$ shell ($KK$) to be $(65\pm5)\%$, which aligns with the $^{124}$Xe nuclear model calculations within 1.8$\,$$σ$.

nucl-ex↗

Search for Solar Boosted Dark Matter Particles at the PandaX-4T Experiment

We present a novel constraint on light dark matter utilizing $1.54$ tonne$\cdot$year of data acquired from the PandaX-4T dual-phase xenon time projection chamber. This constraint is derived through detecting electronic recoil signals resulting from the interaction with solar-enhanced dark matter flux. Low-mass dark matter particles, lighter than a few MeV/$c^2$, can scatter with the thermal electrons in the Sun. Consequently, with higher kinetic energy, the boosted dark matter component becomes detectable via contact scattering with xenon electrons, resulting in a few keV energy deposition that exceeds the threshold of PandaX-4T. We calculate the expected recoil energy in PandaX-4T considering the Sun's acceleration and the detection capabilities of the xenon detector. The first experimental search results using the xenon detector yield the most stringent cross-section of $3.51 \times 10^{-39}~\mathrm{cm}^2$ at $0.08~\mathrm{MeV}$/$c^2$ for a solar boosted dark matter mass ranging from $0.02$ to $10~ \mathrm{MeV}$/$c^2$, achieving a 23 fold improvement compared with earlier experimental studies.

hep-ex↗

Electromagnetic Information Theory: Fundamentals, Paradigm Shifts, and Applications

This paper explores the emerging research direction of electromagnetic information theory (EIT), which aims to integrate traditional Shannon-based methodologies with physical consistency, particularly the electromagnetic properties of communication channels. We propose an EIT-based multiple-input multiple-output (MIMO) paradigm that enhances conventional spatially-discrete MIMO models by incorporating the concepts of electromagnetic (EM) precoding and EM combining. This approach aims to improve the modeling of next-generation systems while remaining consistent with Shannon's theoretical foundations. We explore typical EIT applications, such as densely spaced MIMO, near-field communications, and tri-polarized antennas, and analyze their channel characteristics through theoretical simulations and measured datasets. The paper also discusses critical research challenges and opportunities for EIT applications from an industrial perspective, emphasizing the field's potential for practical applications.

cs.IT↗

Search for Double Beta Decay of $^{136}$Xe to the $0^+_1$ Excited State of $^{136}$Ba with PandaX-4T

We perform a search of double beta decay of $^{136}$Xe to the excited state, $0^+_1$, of $^{136}$Ba (2$νββ$-0$_1^+$), using the dual-phase xenon detector of PandaX-4T with the first 94.9-day commissioning data. The multi-site events are reconstructed up to the MeV energy scale, which helps to improve the background model significantly. The background contribution from the stainless steel platform outside PandaX-4T cryostat is evaluated for the first time. No significant evidence for 2$νββ$-$0_1^+$ is observed, resulting in a lower limit on half-life of $7.5 \times 10^{22}$ yr at the 90% confidence level. This is the first experimental limit on such a rare decay in a natural xenon-based detector.

nucl-ex↗

Search for MeV-Scale Axionlike Particles and Dark Photons with PandaX-4T

Axionlike particles (ALPs) and dark photons (DPs) are viable dark matter particle candidates. We have searched for possible ALP/DP signals in the PandaX-4T liquid xenon detector using 440 kg$\cdot$yr of data. A binned likelihood fit is constructed to search for possible mono-energetic peaks induced by the absorption processes between ALPs/DPs and atomic electrons of xenon. A detailed temporal model of decays associated with xenon isotopes is introduced to constrain the number of background events. No signal excess over background expectations is observed, and we have established the most stringent exclusion limits for most ALP/DP masses across the range of 150 keV/$c^2$ to 1 MeV/$c^2$. The improvement is particularly significant within the mass range of \text{150-400}~keV/$c^2$, with the average factor of 3.5 compared to previous results.

hep-ex↗

Dataset Distillation with Neural Characteristic Function: A Minmax Perspective

Dataset distillation has emerged as a powerful approach for reducing data requirements in deep learning. Among various methods, distribution matching-based approaches stand out for their balance of computational efficiency and strong performance. However, existing distance metrics used in distribution matching often fail to accurately capture distributional differences, leading to unreliable measures of discrepancy. In this paper, we reformulate dataset distillation as a minmax optimization problem and introduce Neural Characteristic Function Discrepancy (NCFD), a comprehensive and theoretically grounded metric for measuring distributional differences. NCFD leverages the Characteristic Function (CF) to encapsulate full distributional information, employing a neural network to optimize the sampling strategy for the CF's frequency arguments, thereby maximizing the discrepancy to enhance distance estimation. Simultaneously, we minimize the difference between real and synthetic data under this optimized NCFD measure. Our approach, termed Neural Characteristic Function Matching (\mymethod{}), inherently aligns the phase and amplitude of neural features in the complex plane for both real and synthetic data, achieving a balance between realism and diversity in synthetic samples. Experiments demonstrate that our method achieves significant performance gains over state-of-the-art methods on both low- and high-resolution datasets. Notably, we achieve a 20.5\% accuracy boost on ImageSquawk. Our method also reduces GPU memory usage by over 300$\times$ and achieves 20$\times$ faster processing speeds compared to state-of-the-art methods. To the best of our knowledge, this is the first work to achieve lossless compression of CIFAR-100 on a single NVIDIA 2080 Ti GPU using only 2.3 GB of memory.

cs.CV↗

Gnothi Seauton: Empowering Faithful Self-Interpretability in Black-Box Transformers

The debate between self-interpretable models and post-hoc explanations for black-box models is central to Explainable AI (XAI). Self-interpretable models, such as concept-based networks, offer insights by connecting decisions to human-understandable concepts but often struggle with performance and scalability. Conversely, post-hoc methods like Shapley values, while theoretically robust, are computationally expensive and resource-intensive. To bridge the gap between these two lines of research, we propose a novel method that combines their strengths, providing theoretically guaranteed self-interpretability for black-box models without compromising prediction accuracy. Specifically, we introduce a parameter-efficient pipeline, AutoGnothi, which integrates a small side network into the black-box model, allowing it to generate Shapley value explanations without changing the original network parameters. This side-tuning approach significantly reduces memory, training, and inference costs, outperforming traditional parameter-efficient methods, where full fine-tuning serves as the optimal baseline. AutoGnothi enables the black-box model to predict and explain its predictions with minimal overhead. Extensive experiments show that AutoGnothi offers accurate explanations for both vision and language tasks, delivering superior computational efficiency with comparable interpretability.

cs.LG↗

Position reconstruction and surface background model for the PandaX-4T detector

We report the position reconstruction methods and surface background model for the PandaX-4T dark matter direct search experiment. This work develops two position reconstruction algorithms: template matching (TM) method and photon acceptance function (PAF) method. Both methods determine the horizontal position of events based on the light pattern of secondary scintillation collected by the light sensors. After a comprehensive evaluation of resolution, uniformity, and robustness, the PAF method was selected for position reconstruction, while the TM method was employed for verification. The PAF method achieves a bulk event resolution of 1.0 mm and a surface event resolution of 4.4 mm for a typical $S2$ signal with a bottom charge of 1500 PE (about 14 keV). The uniformity is around 20\%. Robustness studies reveal average deviations of 5.1 mm and 8.8 mm for the commissioning run (Run0) and the first science run (Run1), respectively, due to the deactivation of certain PMTs. A data-driven surface background model is developed based on the PAF method. The surface background is estimated to be $0.09 \pm 0.06$ events for Run0 (0.54 tonne$\cdot$year) and $0.17 \pm 0.11$ events for Run1 (1.00 tonne$\cdot$year).

physics.ins-det↗

A Novel Low-Background Photomultiplier Tube Developed for Xenon Based Detectors

Photomultiplier tubes (PMTs) are essential in xenon detectors like PandaX, LZ, and XENON experiments for dark matter searches and neutrino properties measurement. To minimize PMT-induced backgrounds, stringent requirements on PMT radioactivity are crucial. A novel 2-inch low-background R12699 PMT has been developed through a collaboration between the PandaX team and Hamamatsu Photonics K.K. corporation. Radioactivity measurements conducted with a high-purity germanium detector show levels of approximately 0.08 mBq/PMT for $\rm^{60}Co$ and 0.06~mBq/PMT for the $\rm^{238}U$ late chain, achieving a 15-fold reduction compared to R11410 PMT used in PandaX-4T. The radon emanation rate is below 3.2 $\rm μ$Bq/PMT (@90\% confidence level), while the surface $\rm^{210}Po$ activity is less than 18.4 $μ$Bq/cm$^2$. The electrical performance of these PMTs at cryogenic temperature was evaluated. With an optimized readout base, the gain was enhanced by 30\%, achieving an average gain of $4.23 \times 10^6$ at -1000~V and -100~$^{\circ}$C. The dark count rate averaged 2.5~Hz per channel. Compactness, low radioactivity, and robust electrical performance in the cryogenic temperature make the R12699 PMT ideal for next-generation liquid xenon detectors and other rare event searches.

physics.ins-det↗

Dark Matter Search Results from 1.54 Tonne$\cdot$Year Exposure of PandaX-4T

In this letter, we report the dark matter search results from the commissioning run and the first science run of the PandaX-4T experiment. A blind analysis is carried out on the entire data set. The data processing is improved compared to previous work, unifying the low-level signal reconstruction in a wide energy range up to 120 keV. With a total exposure of 1.54 tonne$\cdot$year, no significant excess of nuclear recoil events is found. The lowest 90% confidence level exclusion on the spin-independent cross section is $1.6 \times 10^{-47}\,\mathrm{cm}^2$ at a dark matter mass of 40 GeV$/c^2$. Our results represent the most stringent constraint for a dark matter mass above 100 GeV$/c^2$.

hep-ex↗

Exploring New Physics with PandaX-4T Low Energy Electronic Recoil Data

New particles beyond the standard model of particle physics, such as axions, can be effectively searched through their interactions with electrons. We use the large liquid xenon detector PandaX-4T to search for novel electronic recoil signals induced by solar axions, neutrinos with anomalous magnetic moment, axionlike particles, dark photons, and light fermionic dark matter. A detailed background model is established using the latest datasets with 1.54 $\rm ton \cdot yr$ exposure. No significant excess above the background has been observed, and we have obtained competitive constraints for axion couplings, neutrino magnetic moment, and fermionic dark matter interactions.

hep-ex↗

Searching for Neutrinoless Double-Beta Decay of $^{136}$Xe with PandaX-4T

We report the search for neutrinoless double-beta decay of $^{136}$Xe from the PandaX-4T experiment with a 3.7-tonne natural xenon target. The data reconstruction and the background modeling are optimized in the MeV energy region. A blind analysis is performed with data from the commissioning run and the first science run. No significant excess of signal over the background is observed. A lower limit on the half-life of $^{136}$Xe neutrinoless double-beta decay is established to be $2.1 \times 10^{24}$~yr at the 90\% confidence level, with a $^{136}$Xe exposure of 44.6~kg$\cdot$year. Our result represents the most stringent constraint from a natural xenon detector to date.

nucl-ex↗

PandaX-xT: a Multi-ten-tonne Liquid Xenon Observatory at the China Jinping Underground Laboratory

We propose a major upgrade to the existing PandaX-4T experiment in the China Jinping Underground Laboratory. The new experiment, PandaX-xT, will be a multi-ten-tonne liquid xenon, ultra-low background, and general-purpose observatory. The full-scaled PandaX-xT contains a 43-tonne liquid xenon active target. Such an experiment will significantly advance our fundamental understanding of particle physics and astrophysics. The sensitivity of dark matter direct detection will be improved by nearly two orders of magnitude compared to the current best limits, approaching the so-called "neutrino floor" for a dark matter mass above 10 GeV/$c^2$, providing a decisive test to the Weakly Interacting Massive Particle paradigm. By searching for the neutrinoless double beta decay of $^{136}$Xe isotope in the detector, the effective Majorana neutrino mass can be measured to a [10 -- 41] meV/$c^2$ sensitivity, providing a key test to the Dirac/Majorana nature of neutrino s. Astrophysical neutrinos and other ultra-rare interactions can also be measured and searched for with an unprecedented background level, opening up new windows of discovery. Depending on the findings, PandaX-xT will seek the next stage upgrade utilizing isotopic separation on natural xenon.

hep-ex↗

First Indication of Solar $^8$B Neutrino Flux through Coherent Elastic Neutrino-Nucleus Scattering in PandaX-4T

The PandaX-4T liquid xenon detector at the China Jinping Underground Laboratory is used to measure the solar $^8$B neutrino flux by detecting neutrinos through coherent scattering with xenon nuclei. Data samples requiring the coincidence of scintillation and ionization signals (paired), as well as unpaired ionization-only signals (US2), are selected with energy threshold of approximately 1.1 keV (0.33 keV) nuclear recoil energy. Combining the commissioning run and the first science run of PandaX-4T, a total exposure of 1.20 and 1.04 tonne$\cdot$year are collected for the paired and US2, respectively. After unblinding, 3 and 332 events are observed with an expectation of 2.8$\pm$0.5 and 251$\pm$32 background events, for the paired and US2 data, respectively. A combined analysis yields a best-fit $^8$B neutrino signal of 3.5 (75) events from the paired (US2) data sample, with $\sim$37\% uncertainty, and the background-only hypothesis is disfavored at 2.64$σ$ significance. This gives a solar $^8$B neutrino flux of ($8.4\pm3.1$)$\times$10$^6$ cm$^{-2}$s$^{-1}$, consistent with the standard solar model prediction. It is also the first indication of solar $^8$B neutrino ``fog'' in a dark matter direct detection experiment.

hep-ex↗

Search for Cosmic-ray Boosted Sub-MeV Dark-Matter-Electron Scattering in PandaX-4T

We report the first search for the elastic scatterings between cosmic-ray boosted sub-MeV dark matter and electrons in the PandaX-4T liquid xenon experiment. Sub-MeV dark matter particles can be accelerated by scattering with electrons in the cosmic rays and produce detectable electron recoil signals in the detector. Using the commissioning data from PandaX-4T of 0.63~tonne$\cdot$year exposure, we set new constraints on DM-electron scattering cross sections for DM masses ranging from 10~eV/$c^2$ to 3~keV/$c^2$.

hep-ex↗

Constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from PandaX-4T experiment

We present the constraints on the axial-vector and pseudo-scalar mediated WIMP-nucleus interactions from the PandaX-4T experiment, using the data set corresponding to a total exposure of 0.63~tonne$\cdot$year. No significant signal excess is observed, and the most stringent upper limits to date on the spin-dependent WIMP-neutron scattering cross section are set at 90\% confidence level with the minimum WIMP-neutron scattering cross section of 5.8$\times 10^{-42}$\si{\cm^{2}} for WIMP mass of 40~\si{\GeV/}$c^2$. Exclusion limits on the axial-vector and pseudo-scalar simplified models are also derived.

hep-ex↗