Searcharxiv⌕ Search

arXiv subjects

Shaobo Wang

Publications and source records attributed to Shaobo Wang.

At least 109 records · Page 6Linked to original sources

Electromagnetic-Compliant Channel Modeling and Performance Evaluation for Holographic MIMO

Recently, the concept of holographic multiple-input multiple-output (MIMO) is emerging as one of the promising technologies beyond massive MIMO. Many challenges need to be addressed to bring this novel idea into practice, including electromagnetic (EM)-compliant channel modeling and accurate performance evaluation. In this paper, an EM-compliant channel model is proposed for the holographic MIMO systems, which is able to model both the characteristics of the propagation channel and the non-ideal factors caused by mutual coupling at the transceivers, including the antenna pattern distortion and the decrease of antenna efficiency. Based on the proposed channel model, a more realistic performance evaluation is conducted to show the performance of the holographic MIMO system in both the single-user and the multi-user scenarios. Key challenges and future research directions are further provided based on the theoretical analyses and numerical results.

cs.IT↗

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

hep-ex↗

Measurement of Double Beta Decay Half-life of $^{136}$Xe with the PandaX-4T Detector

Precise measurement of two-neutrino double beta decay (DBD) half-life is an important step for the searches of Majorana neutrinos with neutrinoless double beta decay. We report the measurement of DBD half-life of $^{136}$Xe using the PandaX-4T dual-phase Time Projection Chamber (TPC) with 3.7-tonne natural xenon and the first 94.9-day physics data release. The background model in the fiducial volume is well constrained in situ by events in the outer active region. With a $^{136}$Xe exposure of 15.5 kg-year, we establish the half-life as $2.27 \pm 0.03 (stat.)\pm 0.10 (syst.)\times 10^{21}$ years. This is the first DBD half-life measurement with natural xenon and demonstrates the physics capability of a large-scale liquid xenon TPC in the field of rare event searches.

nucl-ex↗

First search for the absorption of fermionic dark matter with the PandaX-4T experiment

Compared with the signature of dark matter elastic scattering off nuclei, the absorption of fermionic dark matter by nuclei opens up a new searching channel for light dark matter with a characteristic monoenergetic signal. In this Letter, we explore the $95.0$-day data from the PandaX-4T commissioning run and report the first dedicated searching results of the fermionic dark matter absorption signal through a neutral current process. No significant signal was found, and the lowest limit on the dark matter-nucleon interaction cross section is set to be $1.5\times10^{-50}$ cm$^2$ for a fermionic dark matter mass of $40$ MeV/$c^2$ with 90\% confidence level.

hep-ex↗

A Gaseous Time Projection Chamber with Micromegas Readout for Low Radioactive Material Screening

Low radioactive material screening is becoming essential for rare event search experiments, such as neutrinoless double beta decay and dark matter searches in underground laboratories. A gaseous time projection chamber (TPC) can be used for such purposes with large active areas and high efficiency. A gaseous TPC with a Micromegas readout plane of approximately 20$\times$20 cm$^2$ is successfully constructed for surface alpha contamination measurements. We have characterized the energy resolution, gain stability, and tracking capability with calibration sources. With the unique track-related background suppression cuts of the gaseous TPC, we have established that the alpha background rate of the TPC is 0.13$\pm$0.03 $μ$Bq/cm$^2$, comparable to the leading commercial solutions.

physics.ins-det↗

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

hep-ex↗

A LN2-based cryogenic system prototype for future PandaX experiment

This paper describes results on R&D of an economical and efficient cryogenic system prototype for future liquid xenon detector. The test module of the prototype has a "cold head" attached to a copper rod, which is specially designed to transport heat loads to a free-boiling liquid nitrogen bath. The performance of the test module and commercial refrigerators is compared. The module with an optimized copper rod has demonstrated more than 1500W cooling power at 178K.The temperature of the "cold head" can be kept stable with an error of 0.02K, its fluctuation is within 0.1K.

physics.ins-det↗

Trap of Feature Diversity in the Learning of MLPs

In this paper, we focus on a typical two-phase phenomenon in the learning of multi-layer perceptrons (MLPs), and we aim to explain the reason for the decrease of feature diversity in the first phase. Specifically, people find that, in the training of MLPs, the training loss does not decrease significantly until the second phase. To this end, we further explore the reason why the diversity of features over different samples keeps decreasing in the first phase, which hurts the optimization of MLPs. We explain such a phenomenon in terms of the learning dynamics of MLPs. Furthermore, we theoretically explain why four typical operations can alleviate the decrease of the feature diversity.

cs.LG↗

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

hep-ex↗

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

physics.ins-det↗

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

hep-ex↗

Measurement of high-pressure xenon gas absorption in acrylic

Acrylic is a popular structural material in experiments requiring low background because of its radio-purity, machinability, and mechanical strength. However, its porosity may cause significant gas absorption and influence the detector stability in the long term. The interaction between acrylic and other detector materials becomes one of the key concerns in the detector design. In this paper, we carry out an experiment to measure quantitatively the absorption process of high-pressure xenon gas into acrylic. A specific setup is designed for the measurement, and systematic measurements are done to obtain a result of the absorption amount: 0.98 g xenon into 332 g of acrylic.

physics.ins-det↗

Screener3D: a Gaseous Time Projection Chamber for Ultra-low Radioactive Material Screening

In experiments searching for rare signals, background events from the detector itself are some of the major factors limiting search sensitivity.Screening for ultra-low radioactive detector materials is becoming ever more essential. We propose to develop a gaseous time projection chamber (TPC) with a Micromegas readout for radio screening. The TPC records three-dimensional trajectories of charged particles emitted from a flat sample placed in the active volume of the detector. The detector can distinguish the origin of an event and identify the particle types with information from trajectories, which significantly increases the screening sensitivity. For $α$ particles from the sample surface, we observe that our proposed detector can reach a sensitivity higher than 100 $μ$Bq$\cdot$m$^{-2}$ within two days.

physics.ins-det↗

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

hep-ex↗

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector's light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

physics.ins-det↗

Visualizing the Emergence of Intermediate Visual Patterns in DNNs

This paper proposes a method to visualize the discrimination power of intermediate-layer visual patterns encoded by a DNN. Specifically, we visualize (1) how the DNN gradually learns regional visual patterns in each intermediate layer during the training process, and (2) the effects of the DNN using non-discriminative patterns in low layers to construct disciminative patterns in middle/high layers through the forward propagation. Based on our visualization method, we can quantify knowledge points (i.e., the number of discriminative visual patterns) learned by the DNN to evaluate the representation capacity of the DNN. Furthermore, this method also provides new insights into signal-processing behaviors of existing deep-learning techniques, such as adversarial attacks and knowledge distillation.

cs.CV↗

Signal identification with Kalman Filter towards background-free neutrinoless double beta decay searches in gaseous detectors

Particle tracks and differential energy loss measured in high pressure gaseous detectors can be exploited for event identification in neutrinoless double beta decay~($0νββ$) searches. We develop a new method based on Kalman Filter in a Bayesian formalism (KFB) to reconstruct meandering tracks of MeV-scale electrons. With simulation data, we compare the signal and background discrimination power of the KFB method assuming different detector granularities and energy resolutions. Typical background from $^{232}$Th and $^{238}$U decay chains can be suppressed by another order of magnitude than that in published literatures, approaching the background-free regime. For the proposed PandaX-III experiment, the $0νββ$ search half-life sensitivity at the 90\% confidence level would reach $2.7 \times 10^{26}$~yr with 5-year live time, a factor of 2.7 improvement over the initial design target.

physics.ins-det↗

Enhanced search sensitivity to the double beta decay of $^{136}$Xe to excited states with topological signatures

Double beta decay of $^{136}$Xe to excited states of $^{136}$Ba (DBD-ES) has not yet been discovered experimentally yet. The experimental signature of such decays, one or two gamma rays following the beta signals, can be identified more effectively in a gaseous detector with the help of topological signatures. We have investigated key parameters of particle trajectories of DBD-ES with Monte Carlo simulation data of the proposed PandaX-III detector as an example. The background rates can be reduced by about one order of magnitude while keeping more than half of signals with topological analysis. The estimated half-life sensitivity of DBD-ES can be improved by 1.8 times to 4.1$\times$10$^{23}$ yr (90\% CL). Similarly, the half-life sensitivity of neutrinoless double beta decay of $^{136}$Xe to excited states of $^{136}$Ba can be improved by a factor of 4.8 with topological signatures.

nucl-ex↗