Searcharxiv⌕ Search

arXiv subjects

Shawn W. Henderson

Publications and source records attributed to Shawn W. Henderson.

At least 19 recordsLinked to original sources

The Simons Observatory: Commissioning of the Mid-Frequency Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO Small Aperture Telescopes (SATs) will cover six spectral bands between 30 and 280 GHz primarily to search for evidence of primordial gravitational waves in the large angular scale $B$-modes of the CMB polarization. The first two Mid-Frequency (MF) SATs, operating in the 90 and 150 GHz frequency bands, began commissioning observations in late 2023, and we present the results of those observations here. Each MF SAT operates with approximately 9,400 biased transition-edge sensors (TES) at 1 mm of precipitable water vapor (PWV), representing a typical 80% yield. Planet observations confirm the telescope optics performance, calibrate the instrument response, and measure the end-to-end optical efficiency of the SATs. The realized instrument efficiencies are within the range expected based on instrument model predictions. In nominal observing conditions, the noise equivalent temperatures from both telescopes combined are $2.4~\mathrm{μK_{CMB}\sqrt{s}}$ at 90 GHz and $3.2~\mathrm{μK_{CMB}\sqrt{s}}$ at 150 GHz, substantially outperforming the baseline instantaneous sensitivity targets for the observatory.

astro-ph.IM↗

The Simons Observatory: Characterization of the 220/280 GHz TES Detector Modules

The Simons Observatory (SO) is a new suite of cosmic microwave background telescopes in the Chilean Atacama Desert with an extensive science program spanning cosmology, Galactic and extragalactic astrophysics, and particle physics. SO will survey the millimeter-wave sky over a wide range of angular scales using six spectral bands across three types of dichroic, polarization-sensitive transition-edge sensor (TES) detector modules: Low-Frequency (LF) modules with bandpasses centered near 30 and 40 GHz, Mid-Frequency (MF) modules near 90 and 150 GHz, and Ultra-High-Frequency (UHF) modules near 220 and 280 GHz. Twenty-five UHF detector modules, each containing 1720 optically-coupled TESs connected to microwave SQUID multiplexing readout, have now been produced. This work summarizes the pre-deployment characterization of these detector modules in laboratory cryostats. Across all UHF modules, we find an average operable TES yield of 83%, equating to over 36,000 devices tested. The distributions of (220, 280) GHz saturation powers have medians of (24, 26) pW, near the centers of their target ranges. For both bands, the median optical efficiency is 0.6, the median effective time constant is 0.4 ms, and the median dark noise-equivalent power (NEP) is ~40 aW/rtHz. The expected photon NEPs at (220, 280) GHz are (64, 99) aW/rtHz, indicating these detectors will achieve background-limited performance on the sky. Thirty-nine UHF and MF detector modules are currently operating in fielded SO instruments, which are transitioning from the commissioning stage to full science observations.

astro-ph.IM↗

Thermal and Electrical Properties of Prototype Readout Components for CMB-S4

CMB-S4 is the fourth-generation ground-based cosmic microwave background project, designed to probe the early universe and cosmic inflation. CMB-S4 would achieve its science goals in part by dramatically increasing the number of transition edge sensor (TES) bolometer detectors on the sky. The detector readout system for CMB-S4 is time-division multiplexing (TDM) with a two-stage Superconducting Quantum Interference Device (SQUID) system. To accommodate the large increase in detectors, the size of our camera increases, placing physical constraints on the readout, its wiring, and its power dissipation. Therefore, to optimize readout performance, we need to balance competing design considerations such as thermal load and bandwidth. We present results characterizing the thermal and electrical performance of prototype components, including wiring and SQUID arrays for CMB-S4, and discuss the impact on overall system performance.

astro-ph.IM↗

The Simons Observatory: Studies of Phase Drift in RF Transmission Lines from the First Large-Scale Deployment of Microwave Frequency Multiplexing for Cosmology

Fulfilling the science goals of the Simons Observatory, a state-of-the-art cosmic microwave background (CMB) experiment, has required deploying tens of thousands of superconducting bolometers. Reading out data from the observatory's more than 67,000 transition-edge sensor (TES) detectors while maintaining cryogenic conditions requires an effective multiplexing scheme. The SLAC microresonator radio frequency (SMuRF) electronics have been developed to provide the warm electronics for a high-density microwave frequency multiplexing readout system, and this system has been shown to achieve multiplexing factors on the order of 1,000. SMuRF has recently been deployed to the Simons Observatory, which is located at 5,200 m on Cerro Toco in Chile's Atacama Desert. As the SMuRF system is exposed to the desert's diurnal temperature swings, resulting phase drift in RF transmission lines may introduce a systematic signal contamination. We present studies of phase drift in the room-temperature RF lines of the Simons Observatory's 6 m large-aperture telescope, which hosts the largest deployment to date of TES microwave frequency multiplexing to a single telescope. We show that these phase drifts occur on time scales which are significantly longer than sky scanning, and that their contribution to on-sky in-transition detector noise is within the readout noise budget.

astro-ph.IM↗

Quantum metrology of low frequency electromagnetic modes with frequency upconverters

We present the RF Quantum Upconverter (RQU) and describe its application to quantum metrology of electromagnetic modes between dc and the Very High Frequency band (VHF) ($\lesssim$300MHz). The RQU uses a Josephson interferometer made up of superconducting loops and Josephson junctions to implement a parametric interaction between a low-frequency electromagnetic mode (between dc and VHF) and a mode in the microwave C Band ($\sim$ 5GHz), analogous to the radiation pressure interaction between electromagnetic and mechanical modes in cavity optomechanics. We analyze RQU performance with quantum amplifier theory, and show that the RQU can operate as a quantum-limited op-amp in this frequency range. It can also use non-classical measurement protocols equivalent to those used in cavity optomechanics, including back-action evading (BAE) measurements, sideband cooling, and two-mode squeezing. These protocols enable experiments using dc--VHF electromagnetic modes as quantum sensors with sensitivity better than the Standard Quantum Limit (SQL). We demonstrate signal upconversion from low frequencies to microwave C band using an RQU and show a phase-sensitive gain (extinction ratio) of $46.9$\;dB, which is a necessary step towards the realization of full BAE.

quant-ph↗

Simons Observatory: Characterization of the Large Aperture Telescope Receiver

The Simons Observatory (SO) is a ground-based cosmic microwave background (CMB) survey experiment that currently consists of three 0.42m small-aperture telescopes (SATs) and one 6m large-aperture telescope (LAT), located at an elevation of 5200m in the Atacama Desert in Chile. At the LAT's focal plane, SO will install >62,000 transition-edge sensor detectors across 13 optics tubes (OTs) within the Large Aperture Telescope Receiver (LATR), the largest cryogenic camera ever built to observe the CMB. Here we report on the validation of the LATR in the laboratory and the subsequent dark testing and validation within the LAT. We show that the LATR meets cryogenic, optical, and detector specifications required for high-sensitivity measurements of the CMB. At the time of writing, the LATR is installed in the LAT with six OTs (corresponding to >31,000 detectors), and the LAT mirrors and remaining seven OTs are undergoing development.

astro-ph.IM↗

The Simons Observatory: Design, Integration, and Current Status of Small Aperture Telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment located in the Atacama Desert in Chile at an elevation of 5200 meters, nominally consisting of an array of three 0.42-meter small aperture telescopes (SATs) and one 6-meter large aperture telescope (LAT). SO will make accurate measurements of the CMB temperature and polarization spanning six frequency bands ranging from 27 to 280 GHz, fielding a total of $\sim$68,000 detectors covering angular scales between one arcminute to tens of degrees. In this paper, we focus on the SATs, which are tailored to search for primordial gravitational waves, with the primary science goal of measuring the primordial tensor-to-scalar ratio \textit{r} at a target level of $σ(r) \approx 0.003$. We discuss the design drivers, scientific impact, and current deployment status of the three SATs, which are scheduled to start taking data in the coming year. The SATs aim to map 10\% of the sky at a 2 $μ$K-arcmin noise level observing at mid-frequencies (93/145 GHz), with additional ultra-high-frequency (225/280 GHz) and low-frequency (27/39 GHz) targets to yield galactic foreground-subtracted measurements.

astro-ph.IM↗

The Simons Observatory: Dark Characterization of the Large Aperture Telescope

The Simons Observatory (SO) is a cosmic microwave background experiment composed of three 0.42 m Small Aperture Telescopes (SATs) and one 6 m Large Aperture Telescope (LAT) in the Atacama Desert of Chile. The Large Aperture Telescope Receiver (LATR) was integrated into the LAT in August 2023; however, because mirrors were not yet installed, the LATR optical chain was capped at the 4K stage. In this dark configuration we are able to characterize many elements of the instrument without contributions from atmospheric noise. Here we show this noise is below the required upper limit and its features are well described with a simple noise model. Maps produced using this noise model have properties that are in good agreement with the white noise levels of our dark data. Additionally, we show that our nominal scan strategy has a minimal effect on the noise when compared to the noise when the telescope is stationary

astro-ph.IM↗

The Precursor Small Aperture Telescope (PreSAT) CMB polarimeter

The search for the polarized imprint of primordial gravitational waves in the cosmic microwave background (CMB) as direct evidence of cosmic inflation requires exquisite sensitivity and control over systematics. The next-generation CMB-S4 project intends to improve upon current-generation experiments by deploying a significantly greater number of highly-sensitive detectors, combined with refined instrument components based on designs from field-proven instruments. The Precursor Small Aperture Telescope (PreSAT) is envisioned as an early step to this next generation, which will test prototype CMB-S4 components and technologies within an existing BICEP Array receiver, with the aim of enabling full-stack laboratory testing and early risk retirement, along with direct correlation of laboratory component-level performance measurements with deployed system performance. The instrument will utilize new 95/155GHz dichroic dual-linear-polarization prototype detectors developed for CMB-S4, cooled to 100mK via the installation of an adiabatic demagnetization refrigerator, along with a prototype readout chain and prototype optics manufactured with wide-band anti-reflection coatings. The experience gained by integrating, deploying, and calibrating PreSAT will also help inform planning for CMB-S4 small aperture telescope commissioning, calibration, and operations well in advance of the fabrication of CMB-S4 production hardware.

astro-ph.IM↗

Development of RFSoC-based direct sampling highly multiplexed microwave SQUID readout for future CMB and submillimeter surveys

The SLAC Microresonator Radio Frequency (SMuRF) electronics is being deployed as the readout for the Cosmic Microwave Background (CMB) telescopes of the Simons Observatory (SO). A Radio Frequency System-on-Chip (RFSoC) based readout of microwave frequency resonator based cryogenic sensors is under development at SLAC as an upgrade path for SMuRF with simplified RF hardware, a more compact footprint, and lower total power consumption. The high-speed integrated data converters and digital data path in RFSoC enable direct RF sampling without analog up and down conversion for RF frequencies up to 6 GHz. A comprehensive optimization and characterization study has been performed for direct RF sampling for microwave SQUID multiplexers, which covers noise level, RF dynamic range, and linearity using a prototype implementation. The SMuRF firmware, including the implementation of closed-loop tone tracking, has been ported to the RFSoC platform and interfaced with the quadrature mixers for digital up and down conversion in the data converter data path to realize a full microwave SQUID multiplexer readout. In this paper, a selection of the performance characterization results of direct RF sampling for microwave SQUID multiplexer readout will be summarized and compared with science-driven requirements. Preliminary results demonstrating the read out of cryogenic sensors using the prototype system will also be presented here. We anticipate our new RFSoC-based SMuRF system will be an enabling readout for on-going and future experiments in astronomy and cosmology, which rely on large arrays of cryogenic sensors to achieve their science goals.

astro-ph.IM↗

The Simons Observatory: Studies of Detector Yield and Readout Noise From the First Large-Scale Deployment of Microwave Multiplexing at the Large Aperture Telescope

The Simons Observatory is a new ground-based cosmic microwave background experiment, which is currently being commissioned in Chile's Atacama Desert. During its survey, the observatory's small aperture telescopes will map 10% of the sky in bands centered at frequencies ranging from 27 to 280 GHz to constrain cosmic inflation models, and its large aperture telescope will map 40% of the sky in the same bands to constrain cosmological parameters and use weak lensing to study large-scale structure. To achieve these science goals, the Simons Observatory is deploying these telescopes' receivers with 60,000 state-of-the-art superconducting transition-edge sensor bolometers for its first five year survey. Reading out this unprecedented number of cryogenic sensors, however, required the development of a novel readout system. The SMuRF electronics were developed to enable high-density readout of superconducting sensors using cryogenic microwave SQUID multiplexing technology. The commissioning of the SMuRF systems at the Simons Observatory is the largest deployment to date of microwave multiplexing technology for transition-edge sensors. In this paper, we show that a significant fraction of the systems deployed so far to the Simons Observatory's large aperture telescope meet baseline specifications for detector yield and readout noise in this early phase of commissioning.

astro-ph.IM↗

The Simons Observatory: Design, integration, and testing of the small aperture telescopes

The Simons Observatory (SO) is a cosmic microwave background (CMB) survey experiment that includes small-aperture telescopes (SATs) observing from an altitude of 5,200 m in the Atacama Desert in Chile. The SO SATs will cover six spectral bands between 27 and 280 GHz to search for primordial B-modes to a sensitivity of $σ(r)=0.002$, with quantified systematic errors well below this value. Each SAT is a self-contained cryogenic telescope with a 35$^\circ$ field of view, 42 cm diameter optical aperture, 40 K half-wave plate, 1 K refractive optics, and $<0.1$ K focal plane that holds $>12,000$ TES detectors. We describe the nominal design of the SATs and present details about the integration and testing for one operating at 93 and 145 GHz.

astro-ph.IM↗

Crosstalk effects in microwave SQUID multiplexed TES bolometer readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

astro-ph.IM↗

End-to-End Modeling of the TDM Readout System for CMB-S4

The CMB-S4 experiment is developing next-generation ground-based microwave telescopes to observe the Cosmic Microwave Background with unprecedented sensitivity. This will require an order of magnitude increase in the 100 mK detector count, which in turn increases the demands on the readout system. The CMB-S4 readout will use time division multiplexing (TDM), taking advantage of faster switches and amplifiers in order to achieve an increased multiplexing factor. To facilitate the design of the new readout system, we have developed a model that predicts the bandwidth and noise performance of this circuity and its interconnections. This is then used to set requirements on individual components in order to meet the performance necessary for the full system. We present an overview of this model and compare the model results to the performance of both legacy and prototype readout hardware.

astro-ph.IM↗

Higher Order Nyquist Zone Sampling with RFSoC Data Converters for Astronomical and High Energy Physics Readout Systems

From generation to generation, the maximum RF frequency and sampling rate of the integrated data converters in RF system-on-chip (RFSoC) family devices from Xilinx increases significantly. With the integrated digital mixers and up and down conversion blocks in the datapaths of the data converters, those RFSoC devices offer the capability for implementing a full readout system of ground and space-based telescopes and detectors across the electromagnetic spectrum within the devices with minimum or no analog mixing circuit. In this paper, we present the characterization results for the the data converters sampling at higher orders of Nyquist zones to extend the frequency range covered for our targeted readout systems of microwave-frequency resonator-based cryogenic detector and multiplexer systems and other astronomical and high-energy physics instrumentation applications, such as, axion search and dark matter detection. The initial evaluation of the data converters operating higher order Nyquist zones covers two-tones and comb of tones tests to address the concerns in the RF inter-modulation distortion, which is the key performance index for our targeted applications. The characterization of the data converters is performed in the bandwidth of 4-6 GHz and results meet our requirements. The settings and operating strategies of the data converters for our targeted applications will be summarised.

astro-ph.IM↗

SLAC Microresonator RF (SMuRF) Electronics: A tone-tracking readout system for superconducting microwave resonator arrays

We describe the newest generation of the SLAC Microresonator RF (SMuRF) electronics, a warm digital control and readout system for microwave-frequency resonator-based cryogenic detector and multiplexer systems such as microwave SQUID multiplexers ($μ$mux) or microwave kinetic inductance detectors (MKIDs). Ultra-sensitive measurements in particle physics and astronomy increasingly rely on large arrays of cryogenic sensors, which in turn necessitate highly multiplexed readout and accompanying room-temperature electronics. Microwave-frequency resonators are a popular tool for cryogenic multiplexing, with the potential to multiplex thousands of detector channels on one readout line. The SMuRF system provides the capability for reading out up to 3328 channels across a 4-8 GHz bandwidth. Notably, the SMuRF system is unique in its implementation of a closed-loop tone-tracking algorithm that minimizes RF power transmitted to the cold amplifier, substantially relaxing system linearity requirements and effective noise from intermodulation products. Here we present a description of the hardware, firmware, and software systems of the SMuRF electronics, comparing achieved performance with science-driven design requirements. We focus in particular on the case of large channel count, low bandwidth applications, but the system has been easily reconfigured for high bandwidth applications. The system described here has been successfully deployed in lab settings and field sites around the world and is baselined for use on upcoming large-scale observatories.

physics.ins-det↗

Phase Drift Monitoring for Tone Tracking Readout of Superconducting Microwave Resonators

A number of modern millimeter, sub-millimeter, and far-infrared detectors are read out using superconducting microwave (1-10GHz) resonators. The main detector technologies are Transition Edge Sensors, read out using Microwave SQUID Multiplexers ($μ$mux) and Microwave Kinetic Inductance Detectors. In these readout schemes, sky signal is encoded as resonance frequency changes. One way to interrogate these superconducting resonators is to calibrate the probe tone phase such that any sky signal induced frequency shifts from the resonators show up primarily as voltage changes in only one of the two quadratures of the interrogation tone. However, temperature variations in the operating environment produce phase drifts that degrade the phase calibration and can source low frequency noise in the final detector time ordered data if left to drift too far from optimal calibration. We present a method for active software monitoring of the time delay through the system which could be used to feedback on the resonator probe tone calibration angle or to apply an offline cleaning. We implement and demonstrate this monitoring method using the SLAC Microresonator RF Electronics on a 65 channel $μ$mux chip from NIST.

physics.ins-det↗

A simulation suite for readout with SMuRF tone-tracking electronics

We present the details of a simulation suite for modeling the effects of readout with SLAC Microresonator RF (SMuRF) electronics. The SMuRF electronics are a warm readout and control system for use with superconducting microwave resonator-based detector systems. The system has been used with the BICEP/Keck program and will be used on the upcoming Simons Observatory and BICEP Array experiments. This simulation suite is a software implementation of the main SMuRF algorithms for offline analysis, modeling, and study. The firmware-implemented algorithms for calibration, resonator frequency estimation, and tone tracking present sources of potential bias or errors if not modeled properly. The simulator takes as input true detector signal, realistic resonator properties, and SMuRF-related user-controlled readout settings. It returns the final flux ramp-demodulated output of a detector timestream as would be passed to the experiment data acquisition system, enabling the analysis of the impact of readout-related parameters on the final science data. It is publicly available in Python with accompanying Jupyter notebooks for user tutorials.

astro-ph.IM↗