Searcharxiv⌕ Search

arXiv subjects

Shenda Hong

Publications and source records attributed to Shenda Hong.

At least 37 records · Page 2Linked to original sources

MieDB-100k: A Comprehensive Dataset for Medical Image Editing

The scarcity of high-quality data remains a primary bottleneck in adapting multimodal generative models for medical image editing. Existing medical image editing datasets often suffer from limited diversity, neglect of medical image understanding and inability to balance quality with scalability. To address these gaps, we propose MieDB-100k, a large-scale, high-quality and diverse dataset for text-guided medical image editing. It categorizes editing tasks into perspectives of Perception, Modification and Transformation, considering both understanding and generation abilities. We construct MieDB-100k via a data curation pipeline leveraging both modality-specific expert models and rule-based data synthetic methods, followed by rigorous manual inspection to ensure clinical fidelity. Extensive experiments demonstrate that model trained with MieDB-100k consistently outperform both open-source and proprietary models while exhibiting strong generalization ability. We anticipate that this dataset will serve as a cornerstone for future advancements in specialized medical image editing.

cs.CV↗

A Scoping Review of Deep Learning Methods for Photoplethysmography Data

Background: Photoplethysmography (PPG) is a non-invasive optical sensing technique widely used to capture hemodynamic information, with broad deployment in both clinical monitoring systems and wearable devices. In recent years, the integration of deep learning has substantially advanced PPG signal analysis and expanded its applications across healthcare and non-healthcare domains. Methods: We conducted a comprehensive literature search for studies applying deep learning to PPG data published between January 1, 2017 and December 31, 2025, using Google Scholar, PubMed, and Dimensions. The included studies were analyzed from three key perspectives: tasks, models, and data. Results: A total of 460 papers applying deep learning techniques to PPG signal analysis were included. These studies span a wide range of application domains, from traditional physiological monitoring tasks such as cardiovascular assessment to emerging applications including sleep analysis, cross-modality signal reconstruction, and biometric identification. Conclusions: Deep learning has significantly advanced PPG signal analysis by enabling more effective extraction of physiological information. Compared with traditional machine learning approaches reliant on handcrafted features, deep learning methods generally achieve improved performance and offer greater flexibility in model development. Nevertheless, several challenges remain, including limited availability of large-scale high-quality datasets, insufficient validation in real-world environments, and concerns over model interpretability, scalability, and computational efficiency. Addressing these challenges and exploring emerging research directions will be essential for further progress in deep learning-based PPG analysis.

cs.AI↗

Masked Training for Robust Arrhythmia Detection from Digitalized Multiple Layout ECG Images

Background: Electrocardiograms are indispensable for diagnosing cardiovascular diseases, yet in many settings they exist only as paper printouts stored in multiple recording layouts. Converting these images into digital signals introduces two key challenges: temporal asynchrony among leads and partial blackout missing, where contiguous signal segments become entirely unavailable. Existing models cannot adequately handle these concurrent problems while maintaining interpretability. Methods: We propose PatchECG, combining an adaptive variable block count missing learning mechanism with a masked training strategy. The model segments each lead into fixed-length patches, discards entirely missing patches, and encodes the remainder via a pluggable patch encoder. A disordered patch attention mechanism with patch-level temporal and lead embeddings captures cross-lead and temporal dependencies without interpolation. PatchECG was trained on PTB-XL and evaluated under seven simulated layout conditions, with external validation on 400 real ECG images from Chaoyang Hospital across three clinical layouts. Results: PatchECG achieves an average AUROC of approximately 0.835 across all simulated layouts. On the Chaoyang cohort, the model attains an overall AUROC of 0.778 for atrial fibrillation detection, rising to 0.893 on the 12x1 subset -- surpassing the pre-trained baseline by 0.111 and 0.190, respectively. Model attention aligns with cardiologist annotations at a rate approaching inter-clinician agreement. Conclusions: PatchECG provides a robust, interpolation-free, and interpretable solution for arrhythmia detection from digitized ECG images across diverse layouts. Its direct modeling of asynchronous and partially missing signals, combined with clinically aligned attention, positions it as a practical tool for cardiac diagnostics from legacy ECG archives in real-world clinical environments.

cs.LG↗

mtslearn: Machine Learning in Python for Medical Time Series

Medical time-series data captures the dynamic progression of patient conditions, playing a vital role in modern clinical decision support systems. However, real-world clinical data is highly heterogeneous and inconsistently formatted. Furthermore, existing machine learning tools often have steep learning curves and fragmented workflows. Consequently, a significant gap remains between cutting-edge AI technologies and clinical application. To address this, we introduce mtslearn, an end-to-end integrated toolkit specifically designed for medical time-series data. First, the framework provides a unified data interface that automates the parsing and alignment of wide, long, and flat data formats. This design significantly reduces data cleaning overhead. Building on this, mtslearn provides a complete pipeline from data reading and feature engineering to model training and result visualization. Furthermore, it offers flexible interfaces for custom algorithms. Through a modular design, mtslearn simplifies complex data engineering tasks into a few lines of code. This significantly lowers the barrier to entry for clinicians with limited programming experience, empowering them to focus more on exploring medical hypotheses and accelerating the translation of advanced algorithms into real-world clinical practice. mtslearn is publicly available at https://github.com/PKUDigitalHealth/mtslearn.

cs.LG↗

Holter-to-Sleep: AI-Enabled Repurposing of Single-Lead ECG for Sleep Phenotyping

Sleep disturbances are tightly linked to cardiovascular risk, yet polysomnography (PSG)-the clinical reference standard-remains resource-intensive and poorly suited for multi-night, home-based, and large-scale screening. Single-lead electrocardiography (ECG), already ubiquitous in Holter and patch-based devices, enables comfortable long-term acquisition and encodes sleep-relevant physiology through autonomic modulation and cardiorespiratory coupling. Here, we present a proof-of-concept Holter-to-Sleep framework that, using single-lead ECG as the sole input, jointly supports overnight sleep phenotyping and Holter-grade cardiac phenotyping within the same recording, and further provides an explicit analytic pathway for scalable cardio-sleep association studies. The framework is developed and validated on a pooled multi-center PSG sample of 10,439 studies spanning four public cohorts, with independent external evaluation to assess cross-cohort generalizability, and additional real-world feasibility assessment using overnight patch-ECG recordings via objective-subjective consistency analysis. This integrated design enables robust extraction of clinically meaningful overnight sleep phenotypes under heterogeneous populations and acquisition conditions, and facilitates systematic linkage between ECG-derived sleep metrics and arrhythmia-related Holter phenotypes. Collectively, the Holter-to-Sleep paradigm offers a practical foundation for low-burden, home-deployable, and scalable cardio-sleep monitoring and research beyond traditional PSG-centric workflows.

eess.SP↗

Artificial intelligence-enabled single-lead ECG for non-invasive hyperkalemia detection: development, multicenter validation, and proof-of-concept deployment

Hyperkalemia is a life-threatening electrolyte disorder that is common in patients with chronic kidney disease and heart failure, yet frequent monitoring remains difficult outside hospital settings. We developed and validated Pocket-K, a single-lead AI-ECG system initialized from the ECGFounder foundation model for non-invasive hyperkalemia screening and handheld deployment. In this multicentre observational study using routinely collected clinical ECG and laboratory data, 34,439 patients contributed 62,290 ECG--potassium pairs. Lead I data were used to fine-tune the model. Data from Peking University People's Hospital were divided into development and temporal validation sets, and data from The Second Hospital of Tianjin Medical University served as an independent external validation set. Hyperkalemia was defined as venous serum potassium > 5.5 mmol/L. Pocket-K achieved AUROCs of 0.936 in internal testing, 0.858 in temporal validation, and 0.808 in external validation. For KDIGO-defined moderate-to-severe hyperkalemia (serum potassium >= 6.0 mmol/L), AUROCs increased to 0.940 and 0.861 in the temporal and external sets, respectively. External negative predictive value exceeded 99.3%. Model-predicted high risk below the hyperkalemia threshold was more common in patients with chronic kidney disease and heart failure. A handheld prototype enabled near-real-time inference, supporting future prospective evaluation in native handheld and wearable settings.

cs.LG↗

SpiroLLM: Finetuning Pretrained LLMs to Understand Spirogram Time Series with Clinical Validation in COPD Reporting

Chronic Obstructive Pulmonary Disease (COPD), a major chronic respiratory disease with persistent airflow limitation, is a leading global cause of disability and mortality. Respiratory spirogram time series, routinely collected during pulmonary function tests (PFTs), play a critical role in the early detection of respiratory diseases and in monitoring lung function over time. However, most current AI models for COPD diagnosis are limited to outputting classification results without providing a rationale for their diagnostic process, while current Large Language Models (LLMs) cannot understand spirograms yet, which severely limits their clinical trust and adoption. To tackle this challenge, we leverage a cohort of 234,028 individuals from the UK Biobank (UKB) to propose SpiroLLM, the first multimodal large language model that can understand spirogram. The model extracts morphological features from respiratory curves via a SpiroEncoder and aligns them with PFT numerical values in a unified latent space using a SpiroProjector, ultimately empowering a large language model to generate a comprehensive diagnostic report. Experimental results confirm that SpiroLLM achieved a diagnostic AUROC of 0.8977 (95% CI: 0.88-0.91). In a robustness test with missing core data, it maintained a 100% valid response rate, far surpassing the 13.4% of a text-only model and showcasing the superiority of its multimodal design. This work demonstrates the substantial potential of deeply fusing physiological signals with large language models, establishing a new paradigm for the next generation of interpretable and reliable clinical decision support tools.

cs.AI↗

Copy-Paste to Mitigate Large Language Model Hallucinations

While Retrieval-Augmented Generation (RAG) enables large language models (LLMs) to generate contextually grounded responses, contextual faithfulness remains challenging as LLMs may not consistently trust provided context, leading to hallucinations that undermine reliability. We observe an inverse correlation between response copying degree and context-unfaithful hallucinations on RAGTruth, suggesting that higher copying degrees reduce hallucinations by fostering genuine contextual belief. We propose CopyPasteLLM, obtained through two-stage high-copying response preference training. We design three prompting methods to enhance copying degree, demonstrating that high-copying responses achieve superior contextual faithfulness and hallucination control. These approaches enable a fully automated pipeline that transforms generated responses into high-copying preference data for training CopyPasteLLM. On FaithEval, ConFiQA and PubMedQA, CopyPasteLLM achieves best performance in both counterfactual and original contexts, remarkably with 12.2% to 24.5% accuracy improvements on FaithEval over the best baseline, while requiring only 365 training samples -- 1/50th of baseline data. To elucidate CopyPasteLLM's effectiveness, we propose the Context-Parameter Copying Capturing algorithm. Interestingly, this reveals that CopyPasteLLM recalibrates reliance on internal parametric knowledge rather than external knowledge during generation. All codes are available at https://github.com/longyongchao/CopyPasteLLM

cs.CL↗

Opportunistic Screening of Wolff-Parkinson-White Syndrome using Single-Lead AI-ECG Mobile System: A Real-World Study of over 3.5 million ECG Recordings in China

Wolff-Parkinson-White (WPW) syndrome, a congenital cardiac conduction abnormality with low prevalence, carries a significant risk of sudden cardiac death. Early identification remains challenging due to screening costs and professional resource scarcity. This retrospective real-world study systematically evaluates an integrated Artificial Intelligence-enabled mobile screening system comprising portable single-lead devices, AI primary screening, and cardiologist review. Analyzing 3,566,626 ECG records from 87,836 individuals between 2019 and 2025, the AI model achieved an AUC of 0.6676 and a specificity of 95.92% in complex real-world signal environments. Despite predictive probability bias inherent in ultra-low prevalence contexts, the model demonstrated stable risk stratification, with high-confidence scores concentrated among true positive individuals. The risk of detecting WPW in AI-positive records was 86.2-fold higher than in AI-negative records. By implementing a human-AI collaborative workflow, the volume of ECGs requiring manual review was reduced by approximately 99.5% compared to universal screening. In an ideal collaborative scenario, an average of only 18 ECGs required review to confirm one WPW case, representing a more than 60-fold increase in screening efficiency. Compared to traditional 12-lead ECGs and electrophysiological studies, this system significantly reduced time and medical costs. Our findings suggest that a risk-stratification-based human-AI collaborative system provides a promising paradigm for the early public health detection of low-prevalence, high-risk arrhythmias.

eess.SP↗

ECGTwin: Personalized ECG Generation Using Controllable Diffusion Model

Personalized electrocardiogram (ECG) generation is to simulate a patient's ECG digital twins tailored to specific conditions. It has the potential to transform traditional healthcare into a more accurate individualized paradigm, while preserving the key benefits of conventional population-level ECG synthesis. However, this promising task presents two fundamental challenges: extracting individual features without ground truth and injecting various types of conditions without confusing generative model. In this paper, we present ECGTwin, a two-stage framework designed to address these challenges. In the first stage, an Individual Base Extractor trained via contrastive learning robustly captures personal features from a reference ECG. In the second stage, the extracted individual features, along with a target cardiac condition, are integrated into the diffusion-based generation process through our novel AdaX Condition Injector, which injects these signals via two dedicated and specialized pathways. Both qualitative and quantitative experiments have demonstrated that our model can not only generate ECG signals of high fidelity and diversity by offering a fine-grained generation controllability, but also preserving individual-specific features. Furthermore, ECGTwin shows the potential to enhance ECG auto-diagnosis in downstream application, confirming the possibility of precise personalized healthcare solutions.

cs.LG↗

ECGomics: An Open Platform for AI-ECG Digital Biomarker Discovery

Background: Conventional electrocardiogram (ECG) analysis faces a persistent dichotomy: expert-driven features ensure interpretability but lack sensitivity to latent patterns, while deep learning offers high accuracy but functions as a black box with high data dependency. We introduce ECGomics, a systematic paradigm and open-source platform for the multidimensional deconstruction of cardiac signals into digital biomarker. Methods: Inspired by the taxonomic rigor of genomics, ECGomics deconstructs cardiac activity across four dimensions: Structural, Intensity, Functional, and Comparative. This taxonomy synergizes expert-defined morphological rules with data-driven latent representations, effectively bridging the gap between handcrafted features and deep learning embeddings. Results: We operationalized this framework into a scalable ecosystem consisting of a web-based research platform and a mobile-integrated solution (https://github.com/PKUDigitalHealth/ECGomics). The web platform facilitates high-throughput analysis via precision parameter configuration, high-fidelity data ingestion, and 12-lead visualization, allowing for the systematic extraction of biomarkers across the four ECGomics dimensions. Complementarily, the mobile interface, integrated with portable sensors and a cloud-based engine, enables real-time signal acquisition and near-instantaneous delivery of structured diagnostic reports. This dual-interface architecture successfully transitions ECGomics from theoretical discovery to decentralized, real-world health management, ensuring professional-grade monitoring in diverse clinical and home-based settings. Conclusion: ECGomics harmonizes diagnostic precision, interpretability, and data efficiency. By providing a deployable software ecosystem, this paradigm establishes a robust foundation for digital biomarker discovery and personalized cardiovascular medicine.

q-bio.QM↗

AnyECG: Evolved ECG Foundation Model for Holistic Health Profiling

Background: Artificial intelligence enabled electrocardiography (AI-ECG) has demonstrated the ability to detect diverse pathologies, but most existing models focus on single disease identification, neglecting comorbidities and future risk prediction. Although ECGFounder expanded cardiac disease coverage, a holistic health profiling model remains needed. Methods: We constructed a large multicenter dataset comprising 13.3 million ECGs from 2.98 million patients. Using transfer learning, ECGFounder was fine-tuned to develop AnyECG, a foundation model for holistic health profiling. Performance was evaluated using external validation cohorts and a 10-year longitudinal cohort for current diagnosis, future risk prediction, and comorbidity identification. Results: AnyECG demonstrated systemic predictive capability across 1172 conditions, achieving an AUROC greater than 0.7 for 306 diseases. The model revealed novel disease associations, robust comorbidity patterns, and future disease risks. Representative examples included high diagnostic performance for hyperparathyroidism (AUROC 0.941), type 2 diabetes (0.803), Crohn disease (0.817), lymphoid leukemia (0.856), and chronic obstructive pulmonary disease (0.773). Conclusion: The AnyECG foundation model provides substantial evidence that AI-ECG can serve as a systemic tool for concurrent disease detection and long-term risk prediction.

eess.SP↗

Artificial Intelligence-Enabled Spirometry for Early Detection of Right Heart Failure

Right heart failure (RHF) is a disease characterized by abnormalities in the structure or function of the right ventricle (RV), which is associated with high morbidity and mortality. Lung disease often causes increased right ventricular load, leading to RHF. Therefore, it is very important to screen out patients with cor pulmonale who develop RHF from people with underlying lung diseases. In this work, we propose a self-supervised representation learning method to early detecting RHF from patients with cor pulmonale, which uses spirogram time series to predict patients with RHF at an early stage. The proposed model is divided into two stages. The first stage is the self-supervised representation learning-based spirogram embedding (SLSE) network training process, where the encoder of the Variational autoencoder (VAE-encoder) learns a robust low-dimensional representation of the spirogram time series from the data-augmented unlabeled data. Second, this low-dimensional representation is fused with demographic information and fed into a CatBoost classifier for the downstream RHF prediction task. Trained and tested on a carefully selected subset of 26,617 individuals from the UK Biobank, our model achieved an AUROC of 0.7501 in detecting RHF, demonstrating strong population-level distinction ability. We further evaluated the model on high-risk clinical subgroups, achieving AUROC values of 0.8194 on a test set of 74 patients with chronic kidney disease (CKD) and 0.8413 on a set of 64 patients with valvular heart disease (VHD). These results highlight the model's potential utility in predicting RHF among clinically elevated-risk populations. In conclusion, this study presents a self-supervised representation learning approach combining spirogram time series and demographic data, demonstrating promising potential for early RHF detection in clinical practice.

cs.LG↗

On-device Computation of Single-lead ECG Parameters for Real-time Remote Cardiac Health Assessment: A Real-world Validation Study

Accurate, continuous out-of-hospital electrocardiogram (ECG) parameter measurement is vital for real-time cardiac health monitoring and telemedicine. On-device computation of single-lead ECG parameters enables timely assessment without reliance on centralized data processing, advancing personalized, ubiquitous cardiac care-yet comprehensive validation across heterogeneous real-world populations remains limited. This study validated the on-device algorithm FeatureDB (https://github.com/PKUDigitalHealth/FeatureDB) using two datasets: HeartVoice-ECG-lite (369 participants with single-lead ECGs annotated by two physicians) and PTB-XL/PTB-XL+ (21,354 patients with 12-lead ECGs and physicians' diagnostic annotations). FeatureDB computed PR, QT, and QTc intervals, with accuracy evaluated against physician annotations via mean absolute error (MAE), correlation analysis, and Bland-Altman analysis. Diagnostic performance for first-degree atrioventricular block (AVBI, PR-based) and long QT syndrome (LQT, QTc-based) was benchmarked against commercial 12-lead systems (12SL, Uni-G) and open-source algorithm Deli, using AUC, accuracy, sensitivity, and specificity. Results showed high concordance with expert annotations (Pearson correlations: 0.836-0.960), MAEs matching inter-observer variability, and minimal bias. AVBI AUC reached 0.787 (12SL: 0.859; Uni-G: 0.812; Deli: 0.501); LQT AUC was 0.684 (12SL: 0.716; Uni-G: 0.605; Deli: 0.569)-comparable to commercial tools and superior to open-source alternatives. FeatureDB delivers physician-level parameter accuracy and commercial-grade abnormality detection via single-lead devices, supporting scalable telemedicine, decentralized cardiac screening, and continuous monitoring in community and outpatient settings.

eess.SP↗

AnyECG-Lab: An Exploration Study of Fine-tuning an ECG Foundation Model to Estimate Laboratory Values from Single-Lead ECG Signals

Timely access to laboratory values is critical for clinical decision-making, yet current approaches rely on invasive venous sampling and are intrinsically delayed. Electrocardiography (ECG), as a non-invasive and widely available signal, offers a promising modality for rapid laboratory estimation. Recent progress in deep learning has enabled the extraction of latent hematological signatures from ECGs. However, existing models are constrained by low signal-to-noise ratios, substantial inter-individual variability, limited data diversity, and suboptimal generalization, especially when adapted to low-lead wearable devices. In this work, we conduct an exploratory study leveraging transfer learning to fine-tune ECGFounder, a large-scale pre-trained ECG foundation model, on the Multimodal Clinical Monitoring in the Emergency Department (MC-MED) dataset from Stanford. We generated a corpus of more than 20 million standardized ten-second ECG segments to enhance sensitivity to subtle biochemical correlates. On internal validation, the model demonstrated strong predictive performance (area under the curve above 0.65) for thirty-three laboratory indicators, moderate performance (between 0.55 and 0.65) for fifty-nine indicators, and limited performance (below 0.55) for sixteen indicators. This study provides an efficient artificial-intelligence driven solution and establishes the feasibility scope for real-time, non-invasive estimation of laboratory values.

cs.LG↗

Combining ECG Foundation Model and XGBoost to Predict In-Hospital Malignant Ventricular Arrhythmias in AMI Patients

Malignant ventricular arrhythmias (VT/VF) following acute myocardial infarction (AMI) are a major cause of in-hospital death, yet early identification remains a clinical challenge. While traditional risk scores have limited performance, end-to-end deep learning models often lack the interpretability needed for clinical trust. This study aimed to develop a hybrid predictive framework that integrates a large-scale electrocardiogram (ECG) foundation model (ECGFounder) with an interpretable XGBoost classifier to improve both accuracy and interpretability. We analyzed 6,634 ECG recordings from AMI patients, among whom 175 experienced in-hospital VT/VF. The ECGFounder model was used to extract 150-dimensional diagnostic probability features , which were then refined through feature selection to train the XGBoost classifier. Model performance was evaluated using AUC and F1-score , and the SHAP method was used for interpretability. The ECGFounder + XGBoost hybrid model achieved an AUC of 0.801 , outperforming KNN (AUC 0.677), RNN (AUC 0.676), and an end-to-end 1D-CNN (AUC 0.720). SHAP analysis revealed that model-identified key features, such as "premature ventricular complexes" (risk predictor) and "normal sinus rhythm" (protective factor), were highly consistent with clinical knowledge. We conclude that this hybrid framework provides a novel paradigm for VT/VF risk prediction by validating the use of foundation model outputs as effective, automated feature engineering for building trustworthy, explainable AI-based clinical decision support systems.

cs.AI↗

GEM: Empowering MLLM for Grounded ECG Understanding with Time Series and Images

While recent multimodal large language models (MLLMs) have advanced automated ECG interpretation, they still face two key limitations: (1) insufficient multimodal synergy between time series signals and visual ECG representations, and (2) limited explainability in linking diagnoses to granular waveform evidence. We introduce GEM, the first MLLM unifying ECG time series, 12-lead ECG images and text for grounded and clinician-aligned ECG interpretation. GEM enables feature-grounded analysis, evidence-driven reasoning, and a clinician-like diagnostic process through three core innovations: a dual-encoder framework extracting complementary time series and image features, cross-modal alignment for effective multimodal understanding, and knowledge-guided instruction generation for generating high-granularity grounding data (ECG-Grounding) linking diagnoses to measurable parameters ($e.g.$, QRS/PR Intervals). Additionally, we propose the Grounded ECG Understanding task, a clinically motivated benchmark designed to comprehensively assess the MLLM's capability in grounded ECG understanding. Experimental results on both existing and our proposed benchmarks show GEM significantly improves predictive performance (CSN $7.4\% \uparrow$), explainability ($22.7\% \uparrow$), and grounding ($24.8\% \uparrow$), making it more suitable for real-world clinical applications. GitHub repository: https://github.com/lanxiang1017/GEM.git

cs.CL↗

Reconstructing 12-Lead ECG from 3-Lead ECG using Variational Autoencoder to Improve Cardiac Disease Detection of Wearable ECG Devices

Twelve-lead electrocardiograms (ECGs) are the clinical gold standard for cardiac diagnosis, providing comprehensive spatial coverage of the heart necessary to detect conditions such as myocardial infarction (MI). However, their lack of portability limits continuous and large-scale use. Three-lead ECG systems are widely used in wearable devices due to their simplicity and mobility, but they often fail to capture pathologies in unmeasured regions. To address this, we propose WearECG, a Variational Autoencoder (VAE) method that reconstructs twelve-lead ECGs from three leads: II, V1, and V5. Our model includes architectural improvements to better capture temporal and spatial dependencies in ECG signals. We evaluate generation quality using MSE, MAE, and Frechet Inception Distance (FID), and assess clinical validity via a Turing test with expert cardiologists. To further validate diagnostic utility, we fine-tune ECGFounder, a large-scale pretrained ECG model, on a multi-label classification task involving over 40 cardiac conditions, including six different myocardial infarction locations, using both real and generated signals. Experiments on the MIMIC dataset show that our method produces physiologically realistic and diagnostically informative signals, with robust performance in downstream tasks. This work demonstrates the potential of generative modeling for ECG reconstruction and its implications for scalable, low-cost cardiac screening.

cs.LG↗