Development of a Neutron Imager using CMOS Pixelated Sensor

We acquired an image of the Siemens Star Chart using the 10B-INTPIX4 CMOS pixelated imager at J-PARC MLF BL21 (NOVA). The image blurriness, characterized by a root mean square (rms) value of 17 um in the line spread function, corresponds to an rms beam divergence of 2.7 mrad. for the neutron beam. This is equivalent to the effective geometrical ratio (L/D ratio) of 370. The contrast of the image was analyzed as a function of structural scale of the chart, and based on this contrast, the modulation transfer function (MTF) of the imaging system was evaluated. The results indicate that the structure corresponding to the 50% cutoff is 12 line-space pairs per mm.

physics.ins-det

Fine residual stress distribution measurement of steel materials by SOI pixel detector with synchrotron X-rays

Residual stress is an important factor governing evaluating and controlling the quality of metal materials in industrial products. X-ray measurements provide one of the most effective means of evaluating residual stress without destruction. In such measurements, the effects of residual stress on the crystal structure can be observed through the Debye ring deformation. In previous studies, we developed a residual stress measurement system based on the $cos \alpha$ method, using a two-dimensional (2D) silicon-on-insulator pixel (SOIPIX) detector known as INTPIX4. In a typical laboratory setup, this system requires only 1 second to measure a specified point. This is drastically faster than the conventional system based on the $sin^{2} \psi$ method, which requires more than 10 min, and the $cos \alpha$-based system using an imaging plate, which requires 1 min. Compared to other systems, it can evaluate the 2D distribution of residual stress faster and provide more detailed information for evaluating materials. We first attempted to measure the 2D distribution in a laboratory setup with a Cr X-ray tube (Cr K$\alpha$ 5.4 keV) and obtained satisfactory results. We subsequently took measurements using synchrotron monochromatic X-rays to determine the fine accuracy and fine sampling pitch distribution. In this paper, we report the results of the initial synchrotron experiment, including the residual stress distribution of the standard specimen obtained by the first prototype setup. Furthermore, we compare the synchrotron measurements with those from the laboratory.

physics.ins-det