SearcharxivSearch

arXiv · 2405.08321

Fine residual stress distribution measurement of steel materials by SOI pixel detector with synchrotron X-rays

Abstract

Residual stress is an important factor governing evaluating and controlling the quality of metal materials in industrial products. X-ray measurements provide one of the most effective means of evaluating residual stress without destruction. In such measurements, the effects of residual stress on the crystal structure can be observed through the Debye ring deformation. In previous studies, we developed a residual stress measurement system based on the $cos \alpha$ method, using a two-dimensional (2D) silicon-on-insulator pixel (SOIPIX) detector known as INTPIX4. In a typical laboratory setup, this system requires only 1 second to measure a specified point. This is drastically faster than the conventional system based on the $sin^{2} \psi$ method, which requires more than 10 min, and the $cos \alpha$-based system using an imaging plate, which requires 1 min. Compared to other systems, it can evaluate the 2D distribution of residual stress faster and provide more detailed information for evaluating materials. We first attempted to measure the 2D distribution in a laboratory setup with a Cr X-ray tube (Cr K$\alpha$ 5.4 keV) and obtained satisfactory results. We subsequently took measurements using synchrotron monochromatic X-rays to determine the fine accuracy and fine sampling pitch distribution. In this paper, we report the results of the initial synchrotron experiment, including the residual stress distribution of the standard specimen obtained by the first prototype setup. Furthermore, we compare the synchrotron measurements with those from the laboratory.

Explore related subjects

Keep this discovery

BibTeXRIS

Ryutaro Nishimura, Shunji Kishimoto, Toshihiko Sasaki, Shingo Mitsui, Masayoshi Shinya, Yasuo Arai, Toshinobu Miyoshi. 2024-05-14. Fine residual stress distribution measurement of steel materials by SOI pixel detector with synchrotron X-rays. https://doi.org/10.1016/j.nima.2020.164380

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det