SearcharxivSearch

arXiv subjects

Shinji Miyoki

Publications and source records attributed to Shinji Miyoki.

15 recordsLinked to original sources

Statistical-Uncertainty-Driven Selection of Evaluation Frequency for Time-Dependent Sensing Calibration: A Demonstration with KAGRA Data

Accurate calibration of the gravitational-wave strain h(t) is essential for both detection and astrophysical inference. In operating detectors, slow temporal variations in the sensing response are tracked using calibration lines, but practical constraints can prevent those lines from being injected at frequencies that are favorable for precise estimation of sensing-side parameters. We present a statistical framework for preselecting evaluation frequencies under such constraints. We apply this framework to KAGRA data from the first part of the fourth LIGO-Virgo-KAGRA Observing Run, for which the nominal cavity-pole frequency was about 18 Hz, while the sensing-side calibration line used in practice was injected at 32.7 Hz. For each candidate evaluation frequency, we construct the sensing function, quantify its segment-wise statistical uncertainty from empirical percentiles of the sample distribution, and rank the candidates using a score that combines the interval widths of the amplitude and phase. When a 1% amplitude interval width and a 1 degree phase interval width are weighted equally, 244 Hz is selected in all 4096 s analysis segments throughout the analyzed period. Relative to the reference frequency of 32.7 Hz, the amplitude interval width is reduced to about one quarter over a broad frequency range, while the phase interval width remains broadly comparable. We also assess the discrepancy introduced by frequency translation separately. These results suggest that the proposed method provides a useful statistical preselection framework for evaluation frequencies under practical operational constraints.

gr-qc

Statistical Estimation and Correction of Model-Measurement Bias in Time-Dependent Correction Factors of KAGRA

Calibration of gravitational-wave detectors reconstructs the strain h(t) from the detector output, and bias and uncertainty in this reconstruction directly affect downstream analyses. In ground-based interferometers, time-dependent correction factors (TDCFs) are estimated from calibration lines to track temporal variations of the detector response, while the underlying model parameters are periodically updated using broadband swept-sine calibration measurements (SSCMs). However, if a model-measurement bias exists between the measured transfer function and the reference model, the TDCFs inferred from calibration lines can introduce a systematic deviation into the reconstructed strain. We propose a statistical framework to estimate and correct this bias using repeated measurement-to-model ratios at the calibration-line frequencies. The bias correction factors are estimated with a rolling random-effects model based on restricted maximum likelihood (REML) and incorporated into the TDCF estimation, with their uncertainty propagated to the reconstructed response. Applying the method to KAGRA O4c data, we find that the uncorrected response shows deviations of up to approximately 7% in magnitude and 5 degrees in phase relative to the SSCM-based reference in representative examples. The correction reduces these deviations, with a modest increase in the propagated uncertainty due to the included correction-factor uncertainty. This framework provides a practical way to combine broadband reference models with calibration-line-based tracking when model-measurement bias is present.

astro-ph.IM

TOrsion-Bar Antenna: A Ground-Based Detector for Low-Frequency Gravity Gradient Measurement

The Torsion-Bar Antenna (TOBA) is a torsion pendulum-based gravitational detector developed to observe gravitational waves in frequencies between 1 mHz and 10 Hz. The low resonant frequency of the torsion pendulum enables observation in this frequency band on the ground. The final target of TOBA is to observe gravitational waves with a 10 m detector and expand the observation band of gravitational waves. In this paper, an overview of TOBA, including the previous prototype experiments and the current ongoing development, is presented.

gr-qc

Cryogenic suspension design for a kilometer-scale gravitational-wave detector

We report the mirror suspension design for Large-scale Cryogenic Gravitational wave Telescope, KAGRA, during bKAGRA Phase 1. Mirror thermal noise is one of the fundamental noises for room-temperature gravitational-wave detectors such as Advanced LIGO and Advanced Virgo. Thus, reduction of thermal noise is required for further improvement of their sensitivity. One effective approach for reducing thermal noise is to cool the mirrors. There are many technical challenges that must be overcome to cool the mirrors, such as cryocooler induced vibrations, thermal drift in suspensions, and reduction in duty cycling due to the increased number of potential failure mechanisms. Our mirror suspension has a black coating that makes radiative cooling more efficient. For conduction cooling, we developed ultra high purity aluminum heat links, which yield high thermal conductivity while keeping the spring constant sufficiently small. A unique inclination adjustment system, called moving mass, is used for aligning the mirror orientation in pitch. Photo-reflective displacement sensors, which have a large range, are installed for damping control on marionette recoil mass and intermediate recoil mass. Samarium cobalt magnets are used for coil-magnet actuators to prevent significant change of magnetism between room temperature and cryogenic temperature. In this paper, the design of our first cryogenic payload and its performance during bKAGRA Phase 1 are discussed.

physics.ins-det

Molecular adsorbed layer formation on cooled mirrors and its impacts on cryogenic gravitational wave telescopes

Cryogenic mirrors have been introduced to the KAGRA gravitational wave telescope in Japan, and are also planned to be used in next-generation gravitational wave telescopes to further improve their sensitivity. Molecular gases inside vacuum chambers adhere to cold mirror surfaces because they lose their kinetic energy when they hit cryogenic surfaces. Finally, a number of adsorbed molecules form an adlayer, which will grow with time. The growing adlayer functions as an optical coating and changes the properties of the underlying mirror, such as reflectance, transmittance, and absorption, which are carefully chosen to maximize the detector sensitivity. The adlayer possibly affects the gravitational wave detector sensitivity. In order to characterize these changes, a high-finesse Fabry--Perot cavity was introduced to a KAGRA cryostat and the finesse of the cavity was monitored for 35 days under cryogenic conditions. We confirmed that the molecular adlayer was formed on a cold mirror and caused an oscillation in the finesse. The real and imaginary parts of the refractive index of the adlayer were $1.26 \pm 0.073$ and $2.2 \times 10^{-7} \pm 1.3 \times 10^{-7} $, respectively. These are considered to be that of $\mathrm{H_2O}$ molecules. The formation rate of the molecular adlayer was 27 $\pm$ 1.9 $\mathrm{nm/day}$. In this paper, we describe theoretical and experimental studies of the formation of a molecular adlayer on cryogenic mirrors. Furthermore, the effects of a molecular adlayer on the quantum noise and the input heat to the test mass are also discussed.

gr-qc

Reduction of thermal fluctuations in a cryogenic laser interferometric gravitational wave detector

The thermal fluctuation of mirror surfaces is the fundamental limitation for interferometric gravitational wave (GW) detectors. Here, we experimentally demonstrate for the first time a reduction in a mirror's thermal fluctuation in a GW detector with sapphire mirrors from the Cryogenic Laser Interferometer Observatory at 17\,K and 18\,K. The detector sensitivity, which was limited by the mirror's thermal fluctuation at room temperature, was improved in the frequency range of 90\,Hz to 240\,Hz by cooling the mirrors. The improved sensitivity reached a maximum of $2.2 \times 10^{-19}\,\textrm{m}/\sqrt{\textrm{Hz}}$ at 165\,Hz.

gr-qc

Thermal-noise-limited underground interferometer CLIO

We report on the current status of CLIO (Cryogenic Laser Interferometer Observatory), which is a prototype interferometer for LCGT (Large Scale Cryogenic Gravitational-Wave Telescope). LCGT is a Japanese next-generation interferometric gravitational wave detector featuring the use of cryogenic mirrors and a quiet underground site. The main purpose of CLIO is to demonstrate a reduction of the mirror thermal noise by cooling the sapphire mirrors. CLIO is located in an underground site of the Kamioka mine, 1000 m deep from the mountain top, to verify its advantages. After a few years of commissioning work, we have achieved a thermal-noise-limited sensitivity at room temperature. One of the main results of noise hunting was the elimination of thermal noise caused by a conductive coil-holder coupled with a pendulum through magnets.

gr-qc

Direct Measurement of Thermal Fluctuation of High-Q Pendulum

We achieved for the first time a direct measurement of the thermal fluctuation of a pendulum in an off-resonant region using a laser interferometric gravitational wave detector. These measurements have been well identified for over one decade by an agreement with a theoretical prediction, which was derived by a fluctuation-dissipation theorem. Thermal fluctuation is dominated by the contribution of resistances in coil-magnet actuator circuits. When we tuned these resistances, the noise spectrum also changed according to a theoretical prediction. The measured thermal noise level corresponds to a high quality factor on the order of 10^5 of the pendulum.

gr-qc

Effect of energy deposited by cosmic-ray particles on interferometric gravitational wave detectors

We investigated the noise of interferometric gravitational wave detectors due to heat energy deposited by cosmic-ray particles. We derived a general formula that describes the response of a mirror against a cosmic-ray passage. We found that there are differences in the comic-ray responses (the dependence of temperature and cosmic-ray track position) in cases of interferometric and resonant gravitational wave detectors. The power spectral density of vibrations caused by low-energy secondary muons is 100-times smaller than the goal sensitivity of future second-generation interferometer projects, such as LCGT and Advanced LIGO. The arrival frequency of high-energy cosmic-ray muons that generate enough large showers inside mirrors of LCGT and Advanced LIGO is one per a millennium. We also discuss the probability of exotic-particle detection with interferometers.

gr-qc

Conduction Effect of Thermal Radiation in a Metal Shield Pipe in a Cryostat for a Cryogenic Interferometric Gravitational Wave Detector

A large heat load caused by thermal radiation through a metal shield pipe was observed in a cooling test of a cryostat for a prototype of a cryogenic interferometric gravitational wave detector. The heat load was approximately 1000 times larger than the value calculated by the Stefan-Boltzmann law. We studied this phenomenon by simulation and experiment and found that it was caused by the conduction of thermal radiation in a metal shield pipe.

physics.ins-det

Current status of Japanese detectors

Current status of TAMA and CLIO detectors in Japan is reported in this article. These two interferometric gravitational-wave detectors are being developed for the large cryogenic gravitational wave telescope (LCGT) which is a future plan for detecting gravitational wave signals at least once per year. TAMA300 is being upgraded to improve the sensitivity in low frequency region after the last observation experiment in 2004. To reduce the seismic noises, we are installing new seismic isolation system, which is called TAMA Seismic Attenuation System, for the four test masses. We confirmed stable mass locks of a cavity and improvements of length and angular fluctuations by using two SASs. We are currently optimizing the performance of the third and fourth SASs. We continue TAMA300 operation and R&D studies for LCGT. Next data taking in the summer of 2007 is planned. CLIO is a 100-m baseline length prototype detector for LCGT to investigate interferometer performance in cryogenic condition. The key features of CLIO are that it locates Kamioka underground site for low seismic noise level, and adopts cryogenic Sapphire mirrors for low thermal noise level. The first operation of the cryogenic interferometer was successfully demonstrated in February of 2006. Current sensitivity at room temperature is close to the target sensitivity within a factor of 4. Several observation experiments at room temperature have been done. Once the displacement noise reaches at thermal noise level of room temperature, its improvement by cooling test mass mirrors should be demonstrated.

gr-qc

Measurement of the mechanical loss of a cooled reflective coating for gravitational wave detection

We have measured the mechanical loss of a dielectric multilayer reflective coating (ion-beam sputtered SiO$_2$ and Ta$_2$O$_5$) in cooled mirrors. The loss was nearly independent of the temperature (4 K $\sim$ 300 K), frequency, optical loss, and stress caused by the coating, and the details of the manufacturing processes. The loss angle was $(4 \sim 6) \times 10^{-4}$. The temperature independence of this loss implies that the amplitude of the coating thermal noise, which is a severe limit in any precise measurement, is proportional to the square root of the temperature. Sapphire mirrors at 20 K satisfy the requirement concerning the thermal noise of even future interferometric gravitational wave detector projects on the ground, for example, LCGT.

gr-qc

Observation results by the TAMA300 detector on gravitational wave bursts from stellar-core collapses

We present data-analysis schemes and results of observations with the TAMA300 gravitational-wave detector, targeting burst signals from stellar-core collapse events. In analyses for burst gravitational waves, the detection and fake-reduction schemes are different from well-investigated ones for a chirp-wave analysis, because precise waveform templates are not available. We used an excess-power filter for the extraction of gravitational-wave candidates, and developed two methods for the reduction of fake events caused by non-stationary noises of the detector. These analysis schemes were applied to real data from the TAMA300 interferometric gravitational wave detector. As a result, fake events were reduced by a factor of about 1000 in the best cases. The resultant event candidates were interpreted from an astronomical viewpoint. We set an upper limit of 2.2x10^3 events/sec on the burst gravitational-wave event rate in our Galaxy with a confidence level of 90%. This work sets a milestone and prospects on the search for burst gravitational waves, by establishing an analysis scheme for the observation data from an interferometric gravitational wave detector.

gr-qc

Thermal lensing in cryogenic sapphire substrates

We report the reduction of the thermal lensing in cryogenic sapphire mirrors, which is planed to be used in the Large scale Cryogenic Gravitational wave Telescope (LCGT) project. We measured three key parameters of sapphire substrate for thermal lensing at cryogenic temperature. They are optical absorption coefficient, thermal conductivity and temperature coefficient of refractive index at cryogenic temperature. On basis of these measurements, we estimated the shot noise sensitivity of the interferometer with thermal lensing by using a wave-front tracing simulation. We found that thermal lensing in cryogenic sapphire mirrors is negligible.

gr-qc

Cryogenic measurement of the optical absorption coefficient in sapphire crystals at 1.064(micro)m for the Large-scale Cryogenic Gravitational wave Telescope

We have applied laser calorimetry to the measurement of optical absorption in mono-crystalline sapphire at cryogenic temperatures. Sapphire is a promising candidate for the mirror substrates of the Large-scale Cryogenic Gravitational wave Telescope. The optical absorption coefficients of different sapphire samples at a wavelength of 1.064(micro)m at 5K were found to average 90ppm/cm.

physics.ins-det