SearcharxivSearch

arXiv subjects

Shuo Diao

Publications and source records attributed to Shuo Diao.

4 recordsLinked to original sources

Fluorescence Imaging In Vivo at Wavelengths beyond 1500 nm

Compared to imaging in the visible and near-infrared regions below 900 nm, imaging in the second near-infrared window (NIR-II, 1000-1700 nm) is a promising method for deep-tissue high-resolution optical imaging in vivo mainly due to the reduced scattering of photons traversing through biological tissues. Herein, semiconducting single-walled carbon nanotubes with large diameters were used for in vivo fluorescence imaging in the long-wavelength NIR region (1500-1700 nm, NIR-IIb). With this imaging agent, 3-4 um wide capillary blood vessels at a depth of about 3 mm could be resolved. Meanwhile, the blood-flow speeds in multiple individual vessels could be mapped simultaneously. Furthermore, NIR-IIb tumor imaging of a live mouse was explored. NIR-IIb imaging can be generalized to a wide range of fluorophores emitting at up to 1700 nm for high-performance in vivo optical imaging.

physics.bio-ph

Through Skull Fluorescence Imaging of the Brain in a New Near-Infrared Window

To date, brain imaging has largely relied on X-ray computed tomography and magnetic resonance angiography with limited spatial resolution and long scanning times. Fluorescence-based brain imaging in the visible and traditional near-infrared regions (400-900 nm) is an alternative but currently requires craniotomy, cranial windows and skull thinning techniques, and the penetration depth is limited to 1-2 mm due to light scattering. Here, we report through-scalp and through-skull fluorescence imaging of mouse cerebral vasculature without craniotomy utilizing the intrinsic photoluminescence of single-walled carbon nanotubes in the 1.3-1.4 micrometre near-infrared window. Reduced photon scattering in this spectral region allows fluorescence imaging reaching a depth of >2 mm in mouse brain with sub-10 micrometre resolution. An imaging rate of ~5.3 frames/s allows for dynamic recording of blood perfusion in the cerebral vessels with sufficient temporal resolution, providing real-time assessment of blood flow anomaly in a mouse middle cerebral artery occlusion stroke model.

physics.med-ph

Ultra-Fast Fluorescence Imaging in Vivo with Conjugated Polymer Fluorophores in the Second Near-Infrared Window

In vivo fluorescence imaging in the second near-infrared window (1.0-1.7 microns) can afford deep tissue penetration and high spatial resolution, owing to the reduced scattering of long-wavelength photons. Here, we synthesize a series of low-bandgap donor/acceptor copolymers with tunable emission wavelengths of 1050-1350 nm in this window. Non-covalent functionalization with phospholipid-polyethylene glycol results in water-soluble and biocompatible polymeric nanoparticles, allowing for live cell molecular imaging at > 1000 nm with polymer fluorophores for the first time. Importantly, the high quantum yield of the polymer allows for in vivo, deep-tissue and ultrafast imaging of mouse arterial blood flow with an unprecedented frame rate of > 25 frames per second. The high time resolution results in spatially and time resolved imaging of the blood flow pattern in cardiogram waveform over a single cardiac cycle (~ 200 ms) of a mouse, which has not been observed with fluorescence imaging in this window before.

physics.bio-ph

Self-Assembly of Semiconducting Single-Walled Carbon Nanotubes into Dense, Aligned Rafts

Single-walled carbon nanotubes are promising nanoelectronic materials but face long-standing challenges including production of pure semiconducting SWNTs and integration into ordered structures. Here, highly pure semiconducting single-walled carbon nanotubes are separated from bulk materials and self-assembled into densely aligned rafts driven by depletion attraction forces. Microscopy and spectroscopy revealed a high degree of alignment and a high packing density of ~100 tubes/micron within SWNT rafts. Field-effect transistors made from aligned SWNT rafts afforded short channel (~150 nm long) devices comprised of tens of purely semiconducting SWNTs derived from chemical separation within a < 1 micron channel width, achieving unprecedented high on-currents (up to ~120 microamperes per device) with high on/off ratios. The average on-current was ~ 3-4 microamperes per tube. The results demonstrated densely aligned high quality semiconducting SWNTs for integration into high performance nanoelectronics.

physics.chem-ph