SearcharxivSearch

arXiv subjects

Simon Rerucha

Publications and source records attributed to Simon Rerucha.

7 recordsLinked to original sources

Monolithic interferometric modules for multi-axis coordinate positioning with sub-nanometre precision

We report on developing, characterizing, and verifying a compact, monolithic laser interferometric assembly designed for high-precision two- and three-axis displacement measurements in coordinate positioning systems. The design targets OEM integration into advanced precision motion platforms, including nanometrology instruments, semiconductor manufacturing equipment, and ultra-high vacuum (UHV) environments. Using a single laser source, the assembly integrates multiple interferometers into a monolithic L-shaped base frame, enabling sub-nanometer periodic error in X-Y motion systems while minimizing geometric and thermal instabilities. The pre-aligned and pre-adjusted architecture simplifies integration, enhances long-term stability, and ensures consistent metrological performance. The system's verification protocol employs quadrature phase analysis and systematic error metrics to characterize performance and optimise assembly. The results indicate sub-nanometer measurement capability and suggest the system's suitability for scalable implementation in advanced coordinate metrology applications.

physics.optics

Country wide Shared FibreBased Infrastructure for Dissemination of Precise Time, Coherent Optical Frequency with Vibration Sensing

With the increasing demand for ultra-precise time synchronization and frequency dissemination across various scientific, industrial, and communication fields, the Czech Republic has developed an innovative, non-commercial fiber-based infrastructure. This infrastructure serves as a shared platform, utilizing optical fibers to enable high-precision timing, coherent frequency transfer, and a newly implemented vibrational sensing capability. The project also addresses challenges posed by classical communication noise-particularly from Raman scattering-on quantum channels, especially for Quantum Key Distribution (QKD). By strategically separating classical and quantum channels into distinct wavelength bands, such as the C-band and O-band, the infrastructure achieves minimal interference while enabling multiple concurrent applications over shared fiber lines.

quant-ph

Characterising and tackling thermally induced zero-drift in displacement measuring interferometry using temperature-controlled enclosure

Our research efforts in displacement measurement interferometry focused on long-term drifts initiated an extended experimental investigation in the interferometric assemblies of our design. We aimed to analyze, characterize and tackle the long-term measurement stability, expressed as the zero-drift, with particular attention to the thermal effects. For the experimentation, we developed a thermostatic chamber equipped with active temperature regulation, an array of sensors and control electronics. With either the finely stabilized temperature or with the thermal cycling, we can carry out a range of investigations: verification of modified design or prototype interferometers, testing of production pieces, characterization of integrated assemblies and units in terms of the zero drift and the susceptibility to thermal effects -- the temperature sensitivity ($\delta L / \delta T$, expressed in nm.K$^{-1}$). With these experimental studies, we demonstrate the potential of the zero drift studies to contribute to the development and broader expansion of interferometric instrumentation.

physics.ins-det

Absolute frequencies of H13C14N hydrogen cyanide transitions in 1,5 {\mu}m region with saturated spectroscopy and sub-kHz scanning laser

The wide span and high density of lines in its rovibrational spectrum render hydrogen cyanide a useful spectroscopic media for referencing absolute frequencies of lasers in optical communication and dimensional metrology. We determined, for the first time to the best of our knowledge, the molecular transitions' center frequencies of the H13C14N isotope in the range from 1526 nm to 1566 nm with 1,3e-10 fractional uncertainty. We investigated the molecular transitions with a highly coherent and widely tunable scanning laser that was precisely referenced to a Hydrogen maser through an optical frequency comb. We demonstrated an approach to stabilize the operational conditions needed to maintain the constantly low pressure of the hydrogen cyanide to carry out the saturated spectroscopy with the third-harmonic synchronous demodulation. We demonstrated approximately a fourtyfold improvement in the line centers' resolution compared to the previous result.

physics.optics

Investigating the use of the hydrogen cyanide (HCN) as an absorption media for laser spectroscopy

The laser spectroscopy is a fundamental approach for the realisation of traceable optical frequency standards. In the $1.55\,\mu$m wavelength band, widely used in telecommunications, the acetylene is the typical and the most widespread absorption media. We present our investigation of using the hydrogen cyanide (HCN) as a cost-efficient and readily available alternative, that also provides a wider frequency span (from $1527\,$nm to $1563\,$nm). We have compared the practical aspects of using new absorption media in comparison to existing experience with the acetylene with an outlook to carry out an independent measurement of the entire spectra. The results should contribute to the future inclusion of the HCN spectroscopic data into the Mise en pratique, thus allowing for the use of HCN as a reference for the realisation of traceable laser standards.

physics.optics

Laser source for dimensional metrology: investigation of an iodine stabilized system based on narrow linewidth 633 nm DBR diode

We demonstrated that an iodine stabilized Distributed Bragg Reflector (DBR) diode based laser system lasing at a wavelength in close proximity to $\lambda = 633\,$nm could be used as an alternative laser source to the He-Ne lasers in both scientific and industrial metrology. This yields additional advantages besides the optical frequency stability and coherence: inherent traceability, wider optical frequency tuning range, higher output power and high frequency modulation capability. We experimentally investigated the characteristics of the laser source in two major steps: first using a wavelength meter referenced to a frequency comb controlled with a hydrogen maser and then on a interferometric optical bench testbed where we compared the performance of the laser system with that of a traditional frequency stabilized He-Ne laser. The results indicate that DBR diode laser system provides a good laser source for applications in dimensional (nano)metrology, especially in conjunction with novel interferometric detection methods exploiting high frequency modulation or multiaxis measurement systems.

physics.optics

Linearized and Compensated Interferometric System for High-Velocity Traceable Length Calibration on a Metre Scale

We report on a traceable calibration system for a 3500mm-long console that carries a measurement system for inspecting the diameter of a circular reactor chassis. The system uses two single-pass laser interferometers with homodyne fringe detection for measurement in two degrees of freedom. The hybrid FPGA-microcontroller control module carries out the fringe detection together with the application-specific scale linearization approach and the compensation of environmental influences such as thermal elongation and the refractive index of air fluctuations. We demonstrated the system feasibility with an accuracy of a few microns and translation velocity higher than 0:1 metre per second.

physics.ins-det