SearcharxivSearch

arXiv subjects

Soki Urano

Publications and source records attributed to Soki Urano.

2 recordsLinked to original sources

In-situ high voltage generation with Cockcroft-Walton multiplier for xenon gas time projection chamber

We have newly developed a Cockcroft-Walton (CW) multiplier that can be used in a gas time projection chamber (TPC). A TPC requires a high voltage to form an electric field that drifts ionization electrons. Supplying the high voltage from outside the pressure vessel requires a dedicated high-voltage feedthrough. An alternative approach is to generate the high voltage inside the pressure vessel with a relatively low voltage introduced from outside. A CW multiplier can convert a low AC voltage input to a high DC voltage output, making it suitable for this purpose. We have integrated a CW multiplier into the AXEL (A Xenon ElectroLuminescence detector), a high pressure xenon gas TPC to search for neutrinoless double beta decay of $^{136}$Xe. It uses silicon photomultipliers to detect the ionization electrons through elecrtoluminescence, making it strong against electronic noise. Operation of the CW multiplier was successfully demonstrated; the TPC was operated for 40 days at 6.8 bar, and an energy resolution as high as (0.67 $\pm$ 0.08) % (FWHM) at 2615 keV was obtained.

physics.ins-det

High-pressure xenon gas time projection chamber with scalable design and its performance at around the Q value of $^{136}$Xe double-beta decay

We have been developing a high-pressure xenon gas time projection chamber (TPC) to search for neutrinoless double beta ($0\nu\beta\beta$) decay of $^{136}$Xe. The unique feature of this TPC is in the detection part of ionization electrons, called ELCC. ELCC is composed of multiple units, and one unit covers 48.5 $\mathrm{cm}^2$. A 180 L size prototype detector with 12 units, 672 channels, of ELCC was constructed and operated with 7.6 bar natural xenon gas to evaluate the performance of the detector at around the Q value of $^{136}$Xe $0\nu\beta\beta$. The obtained FWHM energy resolution is (0.73 $\pm$ 0.11) % at 1836 keV. This corresponds to (0.60 $\pm$ 0.03) % to (0.70 $\pm$ 0.21) % of energy resolution at the Q value of $^{136}Xe$ $0\nu\beta\beta$. This result shows the scalability of the AXEL detector with ELCC while maintaining high energy resolution. Factors determining the energy resolution were quantitatively evaluated and the result indicates further improvement is feasible. Reconstructed track images show distinctive structures at the endpoint of electron tracks, which will be an important feature to distinguish $0\nu\beta\beta$ signals from gamma-ray backgrounds.

physics.ins-det