SearcharxivSearch

arXiv subjects

Stuart J. Ingleby

Publications and source records attributed to Stuart J. Ingleby.

9 recordsLinked to original sources

Field validation of GNSS-independent positioning enhancement using a wearable ultra-stable quantum magnetometer

Increasing the resilience of positioning systems that currently rely on Global Navigation Satellite System (GNSS) signals can be achieved by incorporating stable and sensitive measurements of the permanent crustal anomalies in the Earth's magnetic field. We have realised this concept using an in-house-developed, wearable, Free-Induction-Decay Optically Pumped Magnetometer (FID-OPM) to carry out precise and stable measurements of the geomagnetic field in a walking trial. We present an end-to-end validation, including qualification of FID-OPM performance, alongside quantification of improvement in accuracy when data from this sensor is added to a dead-reckoning estimation of position. Using our wearable sensor system we achieve a Beckmann-distributed radial positioning error of 2.24 m over a route exceeding 500 m in length and spanning approximately 360 s.

physics.atom-ph

Intrinsic atomic calibration of oscillating magnetic fields in ULF and VLF bands

We present a method for absolute calibration of received radio-frequency in the ultra low frequency (ULF), and very low frequency (VLF) range. This is achieved with the use of a radio frequency optically pumped magnetometer (RF-OPM). We describe a method using an optically pumped sample where the RF broadening of the Cs magnetic resonance allows the magnitude of the received field to be calibrated against the ground-state gyromagnetic ratio of the Cs atoms. This frequency-based calibration avoids the geometric and electrostatic response functions that affect inductive sensors, such as fluxgates, search coils, and SQUID magnetometers. We demonstrate calibration of magnetic measurement using oscillating magnetic fields in the 300 Hz - 20 kHz range and a sensor noise floor of 15 fT.Hz-1/2. This radio-frequency sensor may be used as a widely tunable narrowband receiver for communication, ranging, or penetrative conductivity imaging.

physics.atom-ph

High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries

Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of $\mathrm{0.5\,pT/\sqrt{Hz}}$, demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.

physics.atom-ph

Optical pumping enhancement of a free-induction-decay magnetometer

Spin preparation prior to a free-induction-decay (FID) measurement can be adversely affected by transverse bias fields, particularly in the geophysical field range. A strategy that enhances the spin polarization accumulated before readout is demonstrated, by synchronizing optical pumping with a magnetic field pulse that supersedes any transverse fields by over two order of magnitude. The pulsed magnetic field is generated along the optical pumping axis using a compact electromagnetic coil pair encompassing a micro-electromechanical systems (MEMS) vapor cell. The coils also resistively heat the cesium (Cs) vapor to the optimal atomic density without spurious magnetic field contributions as they are rapidly demagnetized to approximately zero field during spin readout. The demagnetization process is analyzed electronically, and directly with a FID measurement, to confirm that the residual magnetic field is minimal during detection. The sensitivity performance of this technique is compared to existing optical pumping modalities across a wide magnetic field range. A noise floor sensitivity of $238\,\mathrm{fT/\surd{Hz}}$ was achieved in a field of approximately $\mathrm{50\,μ{T}}$, in close agreement with the Cramér-Rao lower bound (CRLB) predicted noise density of $258\,\mathrm{fT/\surd{Hz}}$.

physics.atom-ph

Resonant Very Low- and Ultra Low Frequency Digital Signal Reception Using a Portable Atomic Magnetometer

Radio communication through attenuating media necessitates the use of very-low frequency (VLF) and ultra-low frequency (ULF) carrier bands, which are frequently used in underwater and under-ground communication applications. Quantum sensing techniques can be used to circumvent hard constraints on the size, weight and noise floor of classical signal transducers. In this low-frequency range, an optically pumped atomic sample can be used to detect carrier wave modulation resonant with ground-state Zeeman splitting of alkali atoms. Using a compact, self-calibrating system we demonstrate a resonant atomic transducer for digital data encoded using binary phase- and frequency-keying of resonant carrier waves in the 200 Hz -200 kHz range. We present field trial data showing sensor noise floor, decoded data and received bit error rate, and calculate the projected range of sub-sea communication using this device.

physics.atom-ph

Vector Magnetometry Exploiting Phase-Geometry Effects in a Double-Resonance Alignment Magnetometer

Double-resonance optically pumped magnetometers are an attractive instrument for unshielded magnetic field measurements due to their wide dynamic range and high sensitivity. Use of linearly polarised pump light creates alignment in the atomic sample, which evolves in the local static magnetic field, and is driven by a resonant applied field perturbation, modulating the polarisation of transmitted light. We show for the first time that the amplitude and phase of observed first- and second-harmonic components in the transmitted polarisation signal contain sufficient information to measure static magnetic field magnitude and orientation. We describe a laboratory system for experimental measurements of these effects and verify a theoretical derivation of the observed signal. We demonstrate vector field tracking under varying static field orientations and show that the static field magnitude and orientation may be observed simultaneously, with experimentally realised resolution of 1.7 pT and 0.63 mrad in the most sensitive field orientation.

physics.atom-ph

Optically Pumped Magnetometry in Arbitrarily Oriented Magnetic Fields

Optically pumped atomic magnetometers (OPMs) offer highly sensitive magnetic measurements using compact hardware, offering new possibilities for practical precision sensors. Double-resonance OPM operation is well suited to unshielded magnetometry, due to high sensor dynamic range. However, sensor response is highly anisotropic with variation in the orientation of the magnetic field. We present data quantifying these effects and discuss implications for the design of practical sensors.

physics.atom-ph

Orientational Effects on the Amplitude and Phase of Polarimeter Signals in Double Resonance Atomic Magnetometry

Double resonance optically pumped magnetometry can be used to measure static magnetic fields with high sensitivity by detecting a resonant atomic spin response to a small oscillating field perturbation. Determination of the resonant frequency yields a scalar measurement of static field ($B_0$) magnitude. We present calculations and experimental data showing that the on-resonance polarimeter signal of light transmitted through an atomic vapour in arbitrarily oriented $B_0$ may be modelled by considering the evolution of alignment terms in atomic polarisation. We observe that the amplitude and phase of the magnetometer signal are highly dependent upon $B_0$ orientation, and present precise measurements of the distribution of these parameters over the full 4π solid angle.

physics.atom-ph

Grating chips for quantum technologies

We have laser cooled 3$\times10^6$ $^{87}$Rb atoms to 3$μ$K in a micro-fabricated grating magneto-optical trap (GMOT), enabling future mass-deployment in highly accurate compact quantum sensors. We magnetically trap the atoms, and use Larmor spin precession for magnetic sensing in the vicinity of the atomic sample. Finally, we demonstrate an array of magneto-optical traps with a single laser beam, which will be utilised for future cold atom gradiometry.

physics.atom-ph