SearcharxivSearch

arXiv subjects

T. Shiraishi

Publications and source records attributed to T. Shiraishi.

8 recordsLinked to original sources

Gamma-Ray and AntiMatter Survey(GRAMS) experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation experiment using a Liquid Argon Time Projection Chamber (LArTPC) detector to measure MeV gamma rays and antiparticles. MeV gamma-ray observations are important for understanding multi-messenger and time-domain astronomy, enabling exploration of the universe's most potent events, such as supernovae and neutron star mergers. Despite the significance of MeV gamma-rays, GRAMS could also explore the so-called 'MeV gap' region to improve MeV gamma-ray measurement sensitivity that was restricted by the challenge of accurately reconstructing Compton events. Aside from gamma-ray detection, the GRAMS proposed method also serves as an antiparticle spectrometer, targeting the low-energy range of cosmic antinuclei measurements. This work will provide updates on the current status and progress towards the prototype balloon flight with a small-scale LArTPC (pGRAMS) scheduled for early 2026, as well as the recent progress on antihelium-3 sensitivity calculation.

hep-ex

Antihelium-3 Sensitivity for the GRAMS Experiment

The Gamma-Ray and AntiMatter Survey (GRAMS) is a next-generation balloon/satellite mission utilizing a Liquid Argon Time Projection Chamber (LArTPC) detector to measure both MeV gamma rays and antinuclei produced by dark matter annihilation or decay. The GRAMS can identify antihelium-3 events based on the measurements of X-rays and charged pions from the decay of the exotic atoms, Time of Flight (TOF), energy deposition, and stopping range. This paper shows the antihelium-3 sensitivity estimation using a GEANT4 Monte Carlo simulation. For the proposed long-duration balloon (LDB) flight program (35 days $ \times $ 3 flights) and future satellite mission (2-year observation / 10-year observation), the sensitivities become 1.47 $\times$ 10$^{-7}$ [m$^2$ s sr GeV/n]$^{-1}$ and 1.55 $\times$ 10$^{-9}$ [m$^2$ s sr GeV/n]$^{-1}$ / $3.10\times10^{-10}$ [m$^2$ s sr GeV/n]$^{-1}$, respectively. The results indicate that GRAMS can extensively investigate various dark matter models through the antihelium-3 measurements.

hep-ex

First operation of LArTPC in the stratosphere as an engineering GRAMS balloon flight (eGRAMS)

GRAMS (Gamma-Ray and AntiMatter Survey) is a next-generation balloon/satellite experiment utilizing a LArTPC (Liquid Argon Time Projection Chamber), to simultaneously target astrophysical observations of cosmic MeV gamma-rays and conduct an indirect dark matter search using antimatter. While LArTPCs are widely used in particle physics experiments, they have never been operated at balloon altitudes. An engineering balloon flight with a small-scale LArTPC (eGRAMS) was conducted on July 27th, 2023, to establish a system for safely operating a LArTPC at balloon altitudes and to obtain cosmic-ray data from the LArTPC. The flight was launched from the Japan Aerospace Exploration Agency's (JAXA) Taiki Aerospace Research Field in Hokkaido, Japan. The total flight duration was 3 hours and 12 minutes, including a level flight of 44 minutes at a maximum altitude of 28.9 km. The flight system was landed on the sea and successfully recovered. The LArTPC was successfully operated throughout the flight, and about 0.5 million events of the cosmic-ray data including muons, protons, and Compton scattering gamma-ray candidates, were collected. This pioneering flight demonstrates the feasibility of operating a LArTPC in high-altitude environments, paving the way for future GRAMS missions and advancing our capabilities in MeV gamma-ray astronomy and dark matter research.

astro-ph.IM

Directional Sensitivity of the NEWSdm Experiment to Cosmic Ray Boosted Dark Matter

We present a study of a directional search for Dark Matter boosted forward when scattered by cosmic-ray nuclei, using a module of the NEWSdm experiment. The boosted Dark Matter flux at the edge of the Earth's atmosphere is expected to be pointing to the Galactic Center, with a flux 15 to 20 times larger than in the transverse direction. The module of the NEWSdm experiment consists of a 10 kg stack of Nano Imaging Trackers, i.e.~newly developed nuclear emulsions with AgBr crystal sizes down to a few tens of nanometers. The module is installed on an equatorial telescope. The relatively long recoil tracks induced by boosted Dark Matter, combined with the nanometric granularity of the emulsion, result in an extremely low background. This makes an installation at the INFN Gran Sasso laboratory, both on the surface and underground, viable. A comparison between the two locations is made. The angular distribution of nuclear recoils induced by boosted Dark Matter in the emulsion films at the surface laboratory is expected to show an excess with a factor of 3.5 in the direction of the Galactic Center. This excess allows for a Dark Matter search with directional sensitivity. The surface laboratory configuration prevents the deterioration of the signal in the rock overburden and it emerges as the most powerful approach for a directional observation of boosted Dark Matter with high sensitivity. We show that, with this approach, a 10 kg module of the NEWSdm experiment exposed for one year at the Gran Sasso surface laboratory can probe Dark Matter masses between 1 keV/c$^2$ and 1 GeV/c$^2$ and cross-section values down to $10^{-30}$~cm$^2$ with a directional sensitive search.

astro-ph.IM

Environmental sub-MeV neutron measurement at the Gran Sasso surface laboratory with a super-fine-grained nuclear emulsion detector

The measurement of environmental neutrons is particularly important in the search for new physics, such as dark matter particles, because neutrons constitute an often-irreducible background source. The measurement of the neutron energy spectra in the sub-MeV scale is technically difficult because it requires a very good energy resolution and a very high $γ$-ray rejection power. In this study, we used a super-fine-grained nuclear emulsion, called Nano Imaging Tracker (NIT), as a neutron detector. The main target of neutrons is the hydrogen (proton) content of emulsion films. Through a topological analysis, proton recoils induced by neutron scattering can be detected as tracks with sub-micrometric accuracy. This method shows an extremely high $γ$-ray rejection power, at the level of $5 \times 10^7 ~ γ/\rm{cm}^2$, which is equivalent to 5 years accumulation of environmental $γ$-rays, and a very good energy and direction resolution even in the sub-MeV energy region. In order to carry out this measurement with sufficient statistics, we upgraded the automated scanning system to achieve a speed of 250 g/year/machine. We calibrated the detector performance of this system with 880 keV monochromatic neutrons: a very good agreement with the expectation was found for all the relevant kinematic variables. The application of the developed method to a sample exposed at the INFN Gran Sasso surface laboratory provided the first measurement of sub-MeV environmental neutrons with a flux of $(7.6 \pm 1.7) \times 10^{-3} \rm{cm}^{-2} \rm{s}^{-1}$ in the proton energy range between 0.25 and 1 MeV (corresponds to neutron energy range between 0.25 and 10 MeV), consistent with the prediction. The neutron energy and direction distributions also show a good agreement.

physics.ins-det

Development of New Tracking Detector with Fine-grained Nuclear Emulsion for sub-MeV Neutron Measurement

In this study, we have developed a new sub-MeV neutron detector that has a high position resolution, energy resolution, directional sensitivity, and low background. The detector is based on a super-fine-grained nuclear emulsion, called the Nano Imaging Tracker (NIT), and it is capable of detecting neutron induced proton recoils as tracks through topological analysis with sub-micrometric accuracy. We used a type of NIT with AgBr:I crystals of (98 +- 10) nm size dispersed in the gelatin. First, we calibrated the performance of NIT device for detecting monochromatic neutrons with sub-MeV energy generated by nuclear fusion reactions, and the detection efficiency for recoil proton tracks of more than 2 um range was consistently 100\% (the 1 sigma lower limit was 83%) in accordance with expectations by manual based analysis. In addition, recoil energy and angle distribution obtained good agreement with kinematical expectation. The primary neutron energy was reconstructed by using them, and it was evaluated as 42% with FWHM at 540 keV. Furthermore, we demonstrated newly developed an automatic track recognition system dedicated to the track range of more than a few micrometers. It achieved a recognition efficiency of (74 +- 4)%, and recoil energy and angle distribution obtained good agreement with manual analysis. Finally, it indicated the very high rejection power for gamma-rays.

physics.ins-det

First neutrino event detection with nuclear emulsion at J-PARC neutrino beamline

Precise neutrino--nucleus interaction measurements in the sub-multi GeV region are important to reduce the systematic uncertainty in future neutrino oscillation experiments. Furthermore, the excess of ${ν_e}$ interactions, as a possible interpretation of the existence of a sterile neutrino has been observed in such an energy region. The nuclear emulsion technique can measure all the final state particles with low energy threshold for a variety of targets (Fe, C, H${_2}$O, and so on). Its sub-$μ$m position resolution allows measurements of the ${ν_e}$ cross-section with good electron/gamma separation capability. We started a new experiment at J-PARC to study sub-multi GeV neutrino interactions by introducing the nuclear emulsion technique. The J-PARC T60 experiment has been implemented as a first step of such a project. Systematic neutrino event analysis with full scanning data in the nuclear emulsion detector was performed for the first time. The first neutrino event detection and its analysis is described in this paper.

hep-ex

First demonstration of emulsion multi-stage shifter for accelerator neutrino experiment in J-PARC T60

We describe the first ever implementation of an emulsion multi-stage shifter in an accelerator neutrino experiment. The system was installed in the neutrino monitor building in J-PARC as a part of a test experiment T60 and stable operation was maintained for a total of 126.6 days. By applying time information to emulsion films, various results were obtained. Time resolutions of 5.3 to 14.7 s were evaluated in an operation spanning 46.9 days (time resolved numbers of 3.8--1.4$\times10^{5}$). By using timing and spatial information, a reconstruction of coincident events that consisted of high multiplicity events and vertex events, including neutrino events was performed. Emulsion events were matched to events observed by INGRID, one of near detectors of the T2K experiment, with high reliability (98.5\%) and hybrid analysis was established via use of the multi-stage shifter. The results demonstrate that the multi-stage shifter is feasible for use in neutrino experiments.

physics.ins-det