Environmental sub-MeV neutron measurement at the Gran Sasso surface laboratory with a super-fine-grained nuclear emulsion detector

Abstract

The measurement of environmental neutrons is particularly important in the search for new physics, such as dark matter particles, because neutrons constitute an often-irreducible background source. The measurement of the neutron energy spectra in the sub-MeV scale is technically difficult because it requires a very good energy resolution and a very high $γ$-ray rejection power. In this study, we used a super-fine-grained nuclear emulsion, called Nano Imaging Tracker (NIT), as a neutron detector. The main target of neutrons is the hydrogen (proton) content of emulsion films. Through a topological analysis, proton recoils induced by neutron scattering can be detected as tracks with sub-micrometric accuracy. This method shows an extremely high $γ$-ray rejection power, at the level of $5 \times 10^7 ~ γ/\rm{cm}^2$, which is equivalent to 5 years accumulation of environmental $γ$-rays, and a very good energy and direction resolution even in the sub-MeV energy region. In order to carry out this measurement with sufficient statistics, we upgraded the automated scanning system to achieve a speed of 250 g/year/machine. We calibrated the detector performance of this system with 880 keV monochromatic neutrons: a very good agreement with the expectation was found for all the relevant kinematic variables. The application of the developed method to a sample exposed at the INFN Gran Sasso surface laboratory provided the first measurement of sub-MeV environmental neutrons with a flux of $(7.6 \pm 1.7) \times 10^{-3} \rm{cm}^{-2} \rm{s}^{-1}$ in the proton energy range between 0.25 and 1 MeV (corresponds to neutron energy range between 0.25 and 10 MeV), consistent with the prediction. The neutron energy and direction distributions also show a good agreement.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

T. Shiraishi, S. Akamatsu, T. Naka, T. Asada, G. De Lellis, V. Tioukov, G. Rosa, R. Kobayashi, N. Ambrosio, A. Alexandrov, O. Sato. 2022-09-17. Environmental sub-MeV neutron measurement at the Gran Sasso surface laboratory with a super-fine-grained nuclear emulsion detector. https://doi.org/10.1103/physrevc.107.014608

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det