Searcharxiv⌕ Search

arXiv subjects

Takayuki Hayashi

Publications and source records attributed to Takayuki Hayashi.

At least 37 records · Page 2Linked to original sources

In-orbit Performance of the Soft X-ray Imaging Telescope Xtend aboard XRISM

We present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the XRISM mission, based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently-operating X-ray observatories. XRISM/Xtend has a large field of view of $38.5'\times38.5'$, covering an energy range of 0.4--13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170--180 eV at 6 keV, which meets the mission requirement and enables to resolve He-like and H-like Fe K$α$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in SXI onboard the previous Hitomi mission -- light leakage and crosstalk events -- are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C273 results in an effective area measured to be $\sim420$ cm$^{2}$@1.5 keV and $\sim310$ cm$^{2}$@6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations: the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared to other major X-ray instruments onboard satellites, combined with the largest grasp ($Ω_{\rm eff}\sim60$ ${\rm cm^2~degree^2}$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

astro-ph.IM↗

Initial operations of the Soft X-ray Imager onboard XRISM

XRISM (X-Ray Imaging and Spectroscopy Mission) is an astronomical satellite with the capability of high-resolution spectroscopy with the X-ray microcalorimeter, Resolve, and wide field-of-view imaging with the CCD camera, Xtend. Xtend consists of the mirror assembly (XMA: X-ray Mirror Assembly) and detector (SXI: Soft X-ray Imager). The SXI is composed of CCDs, analog and digital electronics, and a mechanical cooler. After the successful launch on September 6th, 2023 (UT) and subsequent critical operations, the mission instruments were turned on and set up. The CCDs have been kept at the designed operating temperature of $-110^\circ$C after the electronics and cooling system were successfully set up. During the initial operation phase, which continued for more than a month after the critical operations, we verified the observation procedure, stability of the cooling system, all the observation options with different imaging areas and/or timing resolutions, and time-tagged and automated operations including those for South Atlantic Anomaly passages. We optimized the operation procedure and observation parameters including the cooler settings, imaging areas for the small window modes, and event selection algorithm. We summarize our policy and procedure of the initial operations for the SXI. We also report on a couple of issues we faced during the initial operations and lessons learned from them.

astro-ph.IM↗

Status of Xtend telescope onboard X-Ray Imaging and Spectroscopy Mission (XRISM)

Xtend is one of the two telescopes onboard the X-ray imaging and spectroscopy mission (XRISM), which was launched on September 7th, 2023. Xtend comprises the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. A large field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized by the combination of the SXI and XMA with a focal length of 5.6 m. The SXI employs four P-channel, back-illuminated type CCDs with a thick depletion layer of 200 $μ$m. The four CCD chips are arranged in a 2$\times$2 grid and cooled down to $-110$ $^{\circ}$C with a single-stage Stirling cooler. Before the launch of XRISM, we conducted a month-long spacecraft thermal vacuum test. The performance verification of the SXI was successfully carried out in a course of multiple thermal cycles of the spacecraft. About a month after the launch of XRISM, the SXI was carefully activated and the soundness of its functionality was checked by a step-by-step process. Commissioning observations followed the initial operation. We here present pre- and post-launch results verifying the Xtend performance. All the in-orbit performances are consistent with those measured on ground and satisfy the mission requirement. Extensive calibration studies are ongoing.

astro-ph.IM↗

Gravitational Redshift Detection from the Magnetic White Dwarf Harbored in RX J1712.6-2414

Gravitational redshift is a fundamental parameter that allows us to determine the mass-to-radius ratio of compact stellar objects, such as black holes, neutron stars, and white dwarfs (WDs). In the X-ray spectra of the close binary system, RX J1712.6$-$2414, obtained from the Chandra High-Energy Transmission Grating observation, we detected significant redshifts for characteristic X-rays emitted from hydrogen-like magnesium, silicon ($ΔE/E_{\rm rest} \sim 7 \times 10^{-4}$), and sulfur ($ΔE/E_{\rm rest} \sim 15 \times 10^{-4}$) ions, which are over the instrumental absolute energy accuracy (${ΔE/E_{\rm rest} \sim 3.3} \times 10^{-4}$). Considering some possible factors, such as Doppler shifts associated with the plasma flow, systemic velocity, and optical depth, we concluded that the major contributor to the observed redshift is the gravitational redshift of the WD harbored in the binary system, which is the first gravitational redshift detection from a magnetic WD. Moreover, the gravitational redshift provides us with a new method of the WD mass measurement by invoking the plasma-flow theory with strong magnetic fields in close binaries. Regardless of large uncertainty, our new method estimated the WD mass to be $M_{\rm WD}> 0.9\,M_{\odot}$.

astro-ph.HE↗

Xtend, the Soft X-ray Imaging Telescope for the X-ray Imaging and Spectroscopy Mission (XRISM)

Xtend is a soft X-ray imaging telescope developed for the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM is scheduled to be launched in the Japanese fiscal year 2022. Xtend consists of the Soft X-ray Imager (SXI), an X-ray CCD camera, and the X-ray Mirror Assembly (XMA), a thin-foil-nested conically approximated Wolter-I optics. The SXI uses the P-channel, back-illuminated type CCD with an imaging area size of 31 mm on a side. The four CCD chips are arranged in a 2$\times$2 grid and can be cooled down to $-120$ $^{\circ}$C with a single-stage Stirling cooler. The XMA nests thin aluminum foils coated with gold in a confocal way with an outer diameter of 45~cm. A pre-collimator is installed in front of the X-ray mirror for the reduction of the stray light. Combining the SXI and XMA with a focal length of 5.6m, a field of view of $38^{\prime}\times38^{\prime}$ over the energy range from 0.4 to 13 keV is realized. We have completed the fabrication of the flight model of both SXI and XMA. The performance verification has been successfully conducted in a series of sub-system level tests. We also carried out on-ground calibration measurements and the data analysis is ongoing.

astro-ph.IM↗

ASCENT - A balloon-borne hard X-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. The isotope ${}^{44}$Ti is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard X-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called ASCENT (A SuperConducting ENergetic x-ray Telescope). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55 eV Full Width Half Maximum (FWHM) energy resolution at 97 keV. This 8--16-fold improvement in energy resolution over NuSTAR will allow high resolution imaging and spectroscopy of the ${}^{44}$Ti emission. This will allow a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as: What is the source of the neutron star "kicks"? What is the dominant production pathway for ${}^{44}$Ti? Is the engine of Cas A unique?

astro-ph.IM↗

X-ray and optical spectroscopic study of a gamma Cassiopeiae analog source pi Aquarii

Gamma Cas analog sources are a subset of Be stars that emit intense and hard X-ray emission. Two competing ideas for their X-ray production mechanism are (a) the magnetic activities of the Be star and its disk and (b) the accretion from the Be star to an unidentified compact object. Among such sources, Pi Aqr plays a pivotal role as it is one of the only two spectroscopic binaries observed for many orbital cycles and one of the three sources with X-ray brightness sufficient for detailed X-ray spectroscopy. Bjorkman et al. (2002) estimated the secondary mass > 2.0 Mo with optical spectroscopy, which would argue against the compact object being a white dwarf (WD). However, their dynamical mass solution is inconsistent with an evolutionary solution and their radial velocity measurement is inconsistent with later work by Naze et al. (2019). We revisit this issue by adding a new data set with the NuSTAR X-ray observatory and the HIDES echelle spectrograph. We found that the radial velocity amplitude is consistent with Naze et al. (2019), which is only a half of that claimed by Bjorkman et al. (2002). Fixing the radial velocity amplitude of the primary, the secondary mass is estimated as < 1.4 Mo over an assumed range of the primary mass and the inclination angle. We further constrained the inclination angle and the secondary mass independently by fitting the X-ray spectra with a non-magnetic or magnetic accreting WD model under the assumption that the secondary is indeed a WD. The two results match well. We thus argue that the possibility of the secondary being a WD should not be excluded for pi Aqr.

astro-ph.HE↗

Breaking the degeneracy in magnetic cataclysmic variable X-ray spectral modeling using X-ray light curves

We present an analysis of mock X-ray spectra and light curves of magnetic cataclysmic variables using an upgraded version of the 3D CYCLOPS code. This 3D representation of the accretion flow allows us to properly model total and partial occultation of the post-shock region by the white dwarf as well as the modulation of the X-ray light curves due to the phase-dependent extinction of the pre-shock region. We carried out detailed post-shock region modeling in a four-dimensional parameter space by varying the white dwarf mass and magnetic field strength as well as the magnetosphere radius and the specific accretion rate. To calculate the post-shock region temperature and density profiles, we assumed equipartition between ions and electrons, took into account the white dwarf gravitational potential, the finite size of the magnetosphere and a dipole-like magnetic field geometry, and considered cooling by both bremsstrahlung and cyclotron radiative processes. By investigating the impact of the parameters on the resulting X-ray continuum spectra, we show that there is an inevitable degeneracy in the four-dimensional parameter space investigated here, which compromises X-ray continuum spectral fitting strategies and can lead to incorrect parameter estimates. However, the inclusion of X-ray light curves in different energy ranges can break this degeneracy, and it therefore remains, in principle, possible to use X-ray data to derive fundamental parameters of magnetic cataclysmic variables, which represents an essential step toward understanding their formation and evolution.

astro-ph.SR↗

Application of a new X-ray reflection model to V1223 Sagittarii

In intermediate polars (IPs), the intrinsic thermal emissions from white dwarfs (WDs) have typically been studied. Few reports have analyzed X-ray reflections from WDs. We recently developed an elaborate IP-reflection spectral model. Herein, we report the first application of a reflection model with an IP thermal model to the spectra of the brightest typical IP V1223 Sagittarii observed by the Suzaku and NuSTAR satellites. The model reasonably reproduces the spectra within the range of 5-78 keV and estimates the WD mass as 0.92$\pm$0.02 $M_\odot$. The WD mass estimated by the proposed model is consistent with that measured using an active galactic nuclei reflection model and a partial covering absorption model. However, the choice of incorrect parameter values, such as an unsuitable fitting energy band and an incorrect metal abundance, was found to introduce systematic errors (e.g., $<\sim$ 0.2 $M_\odot$ in the WD mass) in the WD mass measurement. Our spin phase-resolved analysis resulted in discoveries regarding the modulations of the equivalent width of the fluorescent iron K$_α$ line and the angle between the post-shock accretion column and the line-of-sight (viewing angle). The viewing angle anti-correlates approximately with the X-ray flux and has average and semi-amplitude values of 55$^\circ$ and 7$^\circ$, respectively, which points toward two WD spin axis angles from the line-of-sight of 55$^\circ$ and 7$^\circ$, respectively. Both estimated spin axis angles are different from the reported system inclination of 24$^\circ$.

astro-ph.SR↗

A concept for the X-ray telescope system with an angular-resolution booster

We present a concept of the X-ray imaging system with high angular-resolution and moderate sensitivity. In this concept, a two-dimensional detector, i.e., imager, is put at a slightly out-of-focused position of the focusing mirror, rather than just at the mirror focus as in the standard optics, to capture the miniature image of objects. In addition, a set of multi-grid masks (or a modulation collimator) is installed in front of the telescope. We find that the masks work as a coded aperture camera and that they boost the angular resolution of the focusing optics. The major advantage of this concept is that a much better angular resolution an order of 2--3 or more than in the conventional optics is achievable, while a high throughput (large effective area) is maintained, which is crucial in photon-limited high-energy astronomy, because any type of mirrors, including light-weight reflective mirrors, can be employed in our concept. If the signal-to-noise ratio is sufficiently high, we estimate that angular resolutions at the diffraction limit of 4" and 0"4 at about 7 keV can be achieved with a pair of masks at separations of 1~m and 100~m, respectively, at the diffraction limit.

astro-ph.IM↗

Variation of mass accretion rate onto the white dwarf in the dwarf nova VW Hyi in quiescence

We have analysed a series of Suzaku data and one dataset of XMM-Newton of the SU UMa type dwarf nova VW Hyi in optical quiescence. The observed spectra in the 0.2-10 keV band are moderately well represented by multi-temperature thermal plasma emission models with a maximum temperature of 5-9 keV and bolometric luminosity of 2.4-5.2 $\times$ 10$^{30}$ erg s$^{-1}$. The mass accretion rate derived from the hard X-ray spectra does not show any clear trend as a function of time since the last superoutburst, in contradiction to theoretical predictions of the disc behaviour of a SU UMa type dwarf nova. The mass accretion rate, on the other hand, shows a clear declining trend with time since the last outburst (including the superoutburst). The rate of decline is of the same order as that evaluated from the hard X-ray light curves of the other two dwarf novae SS Cyg and SU UMa. The standard disc instability model, on the other hand, predicts that the mass accretion rate should increase throughout the optically-quiescent phase. We need further observation and theoretical consideration to resolve this discrepancy.

astro-ph.HE↗

Detection of polarized gamma-ray emission from the Crab nebula with Hitomi Soft Gamma-ray Detector

We present the results from the Hitomi Soft Gamma-ray Detector (SGD) observation of the Crab nebula. The main part of SGD is a Compton camera, which in addition to being a spectrometer, is capable of measuring polarization of gamma-ray photons. The Crab nebula is one of the brightest X-ray / gamma-ray sources on the sky, and, the only source from which polarized X-ray photons have been detected. SGD observed the Crab nebula during the initial test observation phase of Hitomi. We performed the data analysis of the SGD observation, the SGD background estimation and the SGD Monte Carlo simulations, and, successfully detected polarized gamma-ray emission from the Crab nebula with only about 5 ks exposure time. The obtained polarization fraction of the phase-integrated Crab emission (sum of pulsar and nebula emissions) is (22.1 $\pm$ 10.6)% and, the polarization angle is 110.7$^o$ + 13.2 / $-$13.0$^o$ in the energy range of 60--160 keV (The errors correspond to the 1 sigma deviation). The confidence level of the polarization detection was 99.3%. The polarization angle measured by SGD is about one sigma deviation with the projected spin axis of the pulsar, 124.0$^o$ $\pm$0.1$^o$.

astro-ph.HE↗

Suzaku and NuSTAR X-Ray Spectroscopy of gamma Cas and HD110432

Gamma Cas and its dozen analogs comprise a small but distinct class of X-ray sources. They are early Be-type stars with an exceptionally hard thermal X-ray emission. The X-ray production mechanism has been under intense debate. Two competing ideas are (i) the magnetic activities in the Be star and its disk and (ii) the mass accretion onto the unidentified white dwarf (WD). We adopt the latter as a working hypothesis and apply physical models developed to describe the X-ray spectra of classical WD binaries containing a late-type companion. Models of non-magnetic and magnetic accreting WDs were applied to gamma Cas and its brightest analog HD110432 using the Suzaku and NuSTAR data. The spectra were fitted by the two models, including the Fe I fluorescence and the Compton reflection in a consistent geometry. The derived physical parameters, such as the WD mass and mass accretion rate, are in a reasonable range in comparison to their classical WD binary counterparts. Additional pieces of evidence in the X-ray spectra (partial covering, Fe L lines, and Fe I fluorescence) were not conclusive enough to classify these two sources into a sub-class of accreting WD binaries. We discuss further observations, especially long-term temporal behaviors, which are important to elucidate the nature of these sources more if indeed they host accreting WDs.

astro-ph.HE↗

Hitomi X-ray Observation of the Pulsar Wind Nebula G21.5$-$0.9

We present results from the Hitomi X-ray observation of a young composite-type supernova remnant (SNR) G21.5$-$0.9, whose emission is dominated by the pulsar wind nebula (PWN) contribution. The X-ray spectra in the 0.8-80 keV range obtained with the Soft X-ray Spectrometer (SXS), Soft X-ray Imager (SXI) and Hard X-ray Imager (HXI) show a significant break in the continuum as previously found with the NuSTAR observation. After taking into account all known emissions from the SNR other than the PWN itself, we find that the Hitomi spectra can be fitted with a broken power law with photon indices of $Γ_1=1.74\pm0.02$ and $Γ_2=2.14\pm0.01$ below and above the break at $7.1\pm0.3$ keV, which is significantly lower than the NuSTAR result ($\sim9.0$ keV). The spectral break cannot be reproduced by time-dependent particle injection one-zone spectral energy distribution models, which strongly indicates that a more complex emission model is needed, as suggested by recent theoretical models. We also search for narrow emission or absorption lines with the SXS, and perform a timing analysis of PSR J1833$-$1034 with the HXI and SGD. No significant pulsation is found from the pulsar. However, unexpectedly, narrow absorption line features are detected in the SXS data at 4.2345 keV and 9.296 keV with a significance of 3.65 $σ$. While the origin of these features is not understood, their mere detection opens up a new field of research and was only possible with the high resolution, sensitivity and ability to measure extended sources provided by an X-ray microcalorimeter.

astro-ph.HE↗

In-flight Calibration of Hitomi Soft X-ray Spectrometer (3) Effective Area

We present the result of the in-flight calibration of the effective area of the Soft X-ray Spectrometer (SXS) onboard the Hitomi X-ray satellite using an observation of the Crab nebula. We corrected for the artifacts when observing high count rate sources with the X-ray microcalorimeter. We then constructed a spectrum in the 0.5-20 keV band, which we modeled with a single power-law continuum attenuated by an interstellar extinction. We evaluated the systematic uncertainty upon the spectral parameters by various calibration items. In the 2-12 keV band, the SXS result is consistent with the literature values in flux (2.20 $\pm$ 0.08) $\times$10$^{-8}$ erg s$^{-1}$ cm$^{-2}$ with a 1$σ$ statistical uncertainty) but is softer in the power-law index (2.19 $\pm$ 0.11). The discrepancy is attributable to the systematic uncertainty of about $+$6/$-$7% and $+$2/$-$5% respectively for the flux and the power-law index. The softer spectrum is affected primarily by the systematic uncertainty of the Dewar gate valve transmission and the event screening.

astro-ph.IM↗

Inflight Calibration of the Hitomi Soft X-ray Spectrometer (2) Point Spread Function

We present results of inflight calibration of the point spread function (PSF) of the Soft X-ray Telescope (SXT-S) that focuses X-ray onto the pixel array of the Soft X-ray Spectrometer system (SXS). We make a full array image of a point-like source by extracting a pulsed component of the Crab nebula emission. Within the limited statistics afforded by an exposure time of only 6.9~ksec and the limited knowledge of the systematic uncetainties, we find that the raytracing model of 1'.2 half-power-diameter (HPD) is consistent with an image of the observed event distributions across pixels. The ratio between the Crab pulsar image and the raytracing shows scatter from pixel to pixel that is 40% or less in all except one pixel. The pixel-to-pixel ratio has a spread of 20%, on average, for the 15 edge pixels, with an averaged statistical error of 17% (1 sigma). In the central 16 pixels, the corresponding ratio is 15% with an error of 6%.

astro-ph.IM↗

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8--20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region $\sim7'$ in diameter. The SXS was operated with an energy resolution of $\sim$5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components are present in the ICM but not detectable by Hitomi SXS given its 1.8--20 keV energy band.

astro-ph.HE↗

Atomic data and spectral modeling constraints from high-resolution X-ray observations of the Perseus cluster with Hitomi

The Hitomi SXS spectrum of the Perseus cluster, with $\sim$5 eV resolution in the 2-9 keV band, offers an unprecedented benchmark of the atomic modeling and database for hot collisional plasmas. It reveals both successes and challenges of the current atomic codes. The latest versions of AtomDB/APEC (3.0.8), SPEX (3.03.00), and CHIANTI (8.0) all provide reasonable fits to the broad-band spectrum, and are in close agreement on best-fit temperature, emission measure, and abundances of a few elements such as Ni. For the Fe abundance, the APEC and SPEX measurements differ by 16%, which is 17 times higher than the statistical uncertainty. This is mostly attributed to the differences in adopted collisional excitation and dielectronic recombination rates of the strongest emission lines. We further investigate and compare the sensitivity of the derived physical parameters to the astrophysical source modeling and instrumental effects. The Hitomi results show that an accurate atomic code is as important as the astrophysical modeling and instrumental calibration aspects. Substantial updates of atomic databases and targeted laboratory measurements are needed to get the current codes ready for the data from the next Hitomi-level mission.

astro-ph.HE↗