Searcharxiv⌕ Search

arXiv subjects

Tao Xue

Publications and source records attributed to Tao Xue.

32 records · Page 2Linked to original sources

Pulse Shape Discrimination of Bulk and Very Bulk Events within HPGe Detectors

The CDEX (China Dark matter Experiment) now deploys ~10 kg pPCGe (p-type Point Contact Germanium) detectors in CJPL (China Jinping Underground Laboratory). It aims to detect rare events such as dark matter and 0vbb (neutrinoless double beta decay). The discrimination of bulk and very bulk events are essential for improvements of the analysis threshold of dark matter. Very bulk events are generated near the p+ point surface of pPCGe, which are usually from radioactive materials of electronic devices. Due to different locations of charge collection, bulk and very bulk events have different pulse shape. This paper will present two linear PSD (Pulse Shape Discrimination) methods: CCM (Charge Comparison Method) and Fisher's LDA (Linear Discriminant Analysis), to realize the discrimination of bulk and very bulk events. The results show that FOMs (Figure of Merit) are 1.38 $\pm$ 0.33 and 1.62 $\pm$ 0.18 by CCM and Fisher's LDA respectively.

physics.ins-det↗

Unbiased Auxiliary Classifier GANs with MINE

Auxiliary Classifier GANs (AC-GANs) are widely used conditional generative models and are capable of generating high-quality images. Previous work has pointed out that AC-GAN learns a biased distribution. To remedy this, Twin Auxiliary Classifier GAN (TAC-GAN) introduces a twin classifier to the min-max game. However, it has been reported that using a twin auxiliary classifier may cause instability in training. To this end, we propose an Unbiased Auxiliary GANs (UAC-GAN) that utilizes the Mutual Information Neural Estimator (MINE) to estimate the mutual information between the generated data distribution and labels. To further improve the performance, we also propose a novel projection-based statistics network architecture for MINE. Experimental results on three datasets, including Mixture of Gaussian (MoG), MNIST and CIFAR10 datasets, show that our UAC-GAN performs better than AC-GAN and TAC-GAN. Code can be found on the project website.

cs.CV↗

Performance of Linear Classification Algorithms on alpha/gamma Discrimination for LaBr3:Ce Scintillation Detectors with Various Pulse Digitizer Properties

With the development of high-speed readout electronics, the digital pulse shape discrimination (PSD) methods have attracted the attention of more researchers, especially in the field of high energy physics and neutron detection. How to choose a PSD algorithm and corresponding data acquisition system (DAQ) naturally becomes a critical problem to settle down for the detection system designers. In this paper, the relationship between the classification performance of different PSD algorithms and digitizers' sampling properties (including sampling rate and the effective number of bits) has been researched based on $\mathrm{LaBr_3}$:Ce scintillation detectors. A self-developed integrated digitizer configured with five different ADCs and a WavePro 404HD oscilloscope were deployed to digitize the waveforms from $\mathrm{LaBr_3}$:Ce scintillators. Moreover, three PSD methods, charge comparison method (CCM), least square for classification method (LS) and Fisher's linear discriminant analysis (LDA), based on linear model were applied to discriminate the alpha signals from the intrinsic isotope $^{227}$Ac. With the LS method and a 125 MSPS 14-Bit ADC, the FoM value was 1.424$\pm$0.042, which is similar to the result from LDA but 31\% better than the result of CCM. The discrimination results showed that the performances of LS and LDA are less affected by the sampling rate with respect to the CCM method, which reflects in a better PSD capability. The results of this paper can help the developers of detector systems to make a trade-off among sampling properties, desirable discrimination results and the cost of systems.

physics.ins-det↗

Results of direct dark matter detection with CDEX experiment at CJPL

The China Dark Matter Experiment (CDEX), located at the China Jinping Underground Laboratory (CJPL) whose overburden is about 2400m rock, aims at direct searches of light Weakly Interacting Massive Particles (WIMPs). A single-element 994-gram p-type point contact (PPC) germanium detector (CDEX-1B) runs inside a solid passive shielding system. To achieve lower background, a prototype 10kg PPC germanium detector array (CDEX-10), consisting of three detector strings with three germanium crystals each, is directly immersed in the liquid nitrogen. With the energy threshold of 160eV, the limits on WIMP-nucleus scattering are set by energy spectra and annual modulation analysis, respectively. Incorporating Migdal effect, the data of CDEX-1B are re-analyzed to search sub-GeV WIMPs. Finally, the future plan of CDEX experiment in CJPL-II is introduced.

hep-ex↗

Prototype of Pulse Digitizer and Readout Electronics for CDEX-10 in CJPL

The CDEX (China Dark matter Experiment) is currently in the stage to upgrade to approximately 10 kg HPGe (High Purity Germanium) detectors (CDEX-10) in CJPL (China Jinping Underground Laboratory) and aims to detect the WIMP (Weakly Interacting Massive Particles). Six analog signals and one inhibited signal are outputted from preamplifier by one HPGe detector (~1 kg) of CDEX-10. The analog signals are conditioned with two 6-us and one 12-us shaping amplifiers, and three timing amplifiers respectively. The inhibited signal is used for trigger. The analog signals from shaping and timing amplifiers are digitized to obtain energy spectrum and rise-time distribution. The rise-time distribution is used to discriminate surface, bulk, and very bulk events, which can help to supress the background level in dark matter detection. Composed of commercial modules, the previous DAQ (Data Acquisition Systems) is insufficient in discriminating between bulk and very bulk events due to the limited sampling rate (100 MSPS). Besides, as number of channel increases, the system will be simplified by integrating the trigger logic in FPGA (Field Programmable Gate Array). In this paper, a prototype named RAIN4HPGe is designed with pulse digitizer and readout electronics, integrating 14-Bit 100 MSPS ADCs (Analog-to-Digital Converters), 12-Bit 1 GSPS ADCs, FPGA etc.. The RAIN1000Z1 readout module based on ZYNQ SoC (System on Chip) is used for readout over Gigabit Ethernet. Better energy resolution, e.g. improving from 558 eV to 474 eV @122 keV, can be achieved by RAIN4HPGe compared to previous DAQ (Data Acquisition Systems) with commercial solution. Moreover, the discrimination performance of bulk, and very bulk events has been improved by RAIN4HPGe with 1 GSPS ADC.

physics.ins-det↗

Optimization of Energy Resolution and Pulse Shape Discrimination for a CLYC Detector with Integrated Digitizers

Sufficient current pulse information of nuclear radiation detectors can be retained by direct waveform digitization owing to the improvement of digitizer's performance. In many circumstances, reasonable cost and power consumption are on demand while the energy resolution and PSD performance should be ensured simultaneously for detectors. This paper will quantitatively analyse the influence of vertical resolution and sampling rate of digitizers on the energy resolution and PSD performance. The energy resolution and PSD performance can be generally optimized by improving the sampling rate and ENOB (effective number of bits) of digitizers. Several integrated digitizers, with sampling rates varying from 100 MSPS to 500 MSPS and vertical resolution ranging from 12-Bit to 16-Bit, were designed and integrated with a CLYC detector for verifications. Experimental results show good accordance with theoretical calculations. The conclusion can give guidance to designs of digitizes for similar applications in need of optimizing the energy resolution and PSD performance, and help to choose proper digitizers for different requirements.

physics.ins-det↗

CDEX dark matter experiment: Status and prospects

The China Dark Matter Experiment (CDEX) aims at direct searches of light Weakly Interacting Massive Particles (WIMPs) at the China Jinping Underground Laboratory (CJPL) with an overburden of about 2400m rock. Results from a prototype CDEX-1 994 g p-type Point Contact Germanium(pPCGe) detector are reported. Research programs are pursued to further reduce the physics threshold by improving hardware and data analysis. The CDEX-10 experiment with a pPCGe array of 10 kg target mass range is being tested. The evolution of CDEX program into "CDEX-1T Experiment" with ton-scale germanium detector arrays will also be introduced in this study.

hep-ex↗

Preliminary Design of Integrated Digitizer Base for Photomultiplier Tube

In many physical experiments and applications with photomultiplier tubes (PMTs), high-speed pulse digitalization is used extensively. The current pulse from a PMT has a rising time of several to a hundred nanoseconds. The current pulse shape can be used to obtain the pulse energy and discriminate between different particles. The conventional readout system with a PMT uses the discrete or integrated pulse-shaping circuits and analogue-to-digital converter boards which are based on the NIM or VME system to implement the data acquisition function. In many applications, such as security instruments, there are only several PMTs used in the whole system, or in some distributed applications, long-distance analogue cable with high-voltage power cable is not applicable due to the tremendous number of channels and enormous distributed space. In this paper, an integrated digitizer base is designed and interfaced with a Cs2LiYCl6 (CLYC) scintillator with a PMT. The CLYC scintillator has the ability to realize the pulse shape discrimination (PSD) between the neutron and gamma-rays. There is only one Gigabit of unscreened twisted-pair cable needed for over 700 Mbps TCP data throughput and more than 10 W power. The boards of high voltage supply, current sensitive preamplifier, 500 MSPS/12-Bit ADC (Analog-to-Digital Converter), readout module based on ZYNQ SoC (System on Chip), power over Ethernet, and user interface circuits are stacked with board-to-board connectors. The system can achieve 4.6% gamma-ray energy resolution at 662 keV with a 20-μs pulse integral and PSD figure-of-merit of ~3.0 for the whole energy of neutrons and gamma-rays. This integrated digitizer base can also be interfaced with other detectors with a PMT.

physics.ins-det↗

The first result on 76Ge neutrinoless double beta decay from CDEX-1 experiment

We report the first result on Ge-76 neutrinoless double beta decay from CDEX-1 experiment at China Jinping Underground Laboratory. A mass of 994 g p-type point-contact high purity germanium detector has been installed to search the neutrinoless double beta decay events, as well as to directly detect dark matter particles. An exposure of 304 kg*day has been analyzed. The wideband spectrum from 500 keV to 3 MeV was obtained and the average event rate at the 2.039 MeV energy range is about 0.012 count per keV per kg per day. The half-life of Ge-76 neutrinoless double beta decay has been derived based on this result as: T 1/2 > 6.4*10^22 yr (90% C.L.). An upper limit on the effective Majorana-neutrino mass of 5.0 eV has been achieved. The possible methods to further decrease the background level have been discussed and will be pursued in the next stage of CDEX experiment.

hep-ex↗

A Prototype of LaBr3:Ce in situ Gamma-Ray Spectrometer for Marine Environmental Monitoring

A prototype of LaBr3:Ce in situ gamma-ray spectrometer for marine environmental monitoring is developed and applied for in situ measurement. A 3-inch LaBr3:Ce scintillator is used in the detector, and a digital pulse process electronics is chosen as the pulse height analyzer. For this prototype, the energy response of the spectrometer is linear and the energy resolution of 662keV is 2.6% (much better than NaI). With the measurement of the prototype in a water tank filled with 137Cs, the detect efficiency for 137Cs is (0.288 0.01)cps/(Bq/L), which is close to the result of Monte Carlo simulation, 0.283cps/(Bq/L). With this measurement, the MDAC for 137Cs in one hour has been calculated to 0.78Bq/L, better than that of NaI(Tl) in-situ gamma spectrometer, which is ~1.0Bq/L.

physics.ins-det↗

Study of the material photon and electron background and the liquid argon detector veto efficiency of the CDEX-10 experiment

The China Dark Matter Experiment (CDEX) is located at the China Jinping underground laboratory (CJPL) and aims to directly detect the WIMP flux with high sensitivity in the low mass region. Here we present a study of the predicted photon and electron backgrounds including the background contribution of the structure materials of the germanium detector, the passive shielding materials, and the intrinsic radioactivity of the liquid argon that serves as an anti-Compton active shielding detector. A detailed geometry is modeled and the background contribution has been simulated based on the measured radioactivities of all possible components within the GEANT4 program. Then the photon and electron background level in the energy region of interest (<10^-2 events kg-1 day-1 keV-1 (cpkkd)) is predicted based on Monte Carlo simulations. The simulated result is consistent with the design goal of CDEX-10 experiment, 0.1 cpkkd, which shows that the active and passive shield design of CDEX-10 is effective and feasible.

physics.ins-det↗

Measurement of Cosmic Ray Flux in China JinPing underground Laboratory

China JinPing underground Laboratory (CJPL) is the deepest underground laboratory presently running in the world. In such a deep underground laboratory, the cosmic ray flux is a very important and necessary parameter for rare event experiments. A plastic scintillator telescope system has been set up to measure the cosmic ray flux. The performance of the telescope system has been studied using the cosmic ray on the ground laboratory near CJPL. Based on the underground experimental data taken from November 2010 to December 2011 in CJPL, which has effective live time of 171 days, the cosmic ray muon flux in CJPL is measured to be (2.0+-0.4)*10^(-10)/(cm^2)/(s). The ultra-low cosmic ray background guarantees CJPL's ideal environment for dark matter experiment.

physics.ins-det↗

The CDEX-1 1 kg Point-Contact Germanium Detector for Low Mass Dark Matter Searches

The CDEX Collaboration has been established for direct detection of light dark matter particles, using ultra-low energy threshold p-type point-contact germanium detectors, in China JinPing underground Laboratory (CJPL). The first 1 kg point-contact germanium detector with a sub-keV energy threshold has been tested in a passive shielding system located in CJPL. The outputs from both the point-contact p+ electrode and the outside n+ electrode make it possible to scan the lower energy range of less than 1 keV and at the same time to detect the higher energy range up to 3 MeV. The outputs from both p+ and n+ electrode may also provide a more powerful method for signal discrimination for dark matter experiment. Some key parameters, including energy resolution, dead time, decay times of internal X-rays, and system stability, have been tested and measured. The results show that the 1 kg point-contact germanium detector, together with its shielding system and electronics, can run smoothly with good performances. This detector system will be deployed for dark matter search experiments.

physics.ins-det↗

Introduction of the CDEX experiment

Weakly Interacting Massive Particles (WIMPs) are the candidates of dark matter in our universe. Up to now any direct interaction of WIMP with nuclei has not been observed yet. The exclusion limits of the spin-independent cross section of WIMP-nucleon which have been experimentally obtained is about 10^{-7}pb at high mass region and only 10^{-5}pb} at low mass region. China Jin-Ping underground laboratory CJPL is the deepest underground lab in the world and provides a very promising environment for direct observation of dark matter. The China Dark Matter Experiment (CDEX) experiment is going to directly detect the WIMP flux with high sensitivity in the low mass region. Both CJPL and CDEX have achieved a remarkable progress in recent two years. The CDEX employs a point-contact germanium semi-conductor detector PCGe whose detection threshold is less than 300 eV. We report the measurement results of Muon flux, monitoring of radioactivity and Radon concentration carried out in CJPL, as well describe the structure and performance of the 1 kg PCGe detector CDEX-1 and 10kg detector array CDEX-10 including the detectors, electronics, shielding and cooling systems. Finally we discuss the physics goals of the CDEX-1, CDEX-10 and the future CDEX-1T detectors.

physics.ins-det↗