Preliminary Design of Integrated Digitizer Base for Photomultiplier Tube

Abstract

In many physical experiments and applications with photomultiplier tubes (PMTs), high-speed pulse digitalization is used extensively. The current pulse from a PMT has a rising time of several to a hundred nanoseconds. The current pulse shape can be used to obtain the pulse energy and discriminate between different particles. The conventional readout system with a PMT uses the discrete or integrated pulse-shaping circuits and analogue-to-digital converter boards which are based on the NIM or VME system to implement the data acquisition function. In many applications, such as security instruments, there are only several PMTs used in the whole system, or in some distributed applications, long-distance analogue cable with high-voltage power cable is not applicable due to the tremendous number of channels and enormous distributed space. In this paper, an integrated digitizer base is designed and interfaced with a Cs2LiYCl6 (CLYC) scintillator with a PMT. The CLYC scintillator has the ability to realize the pulse shape discrimination (PSD) between the neutron and gamma-rays. There is only one Gigabit of unscreened twisted-pair cable needed for over 700 Mbps TCP data throughput and more than 10 W power. The boards of high voltage supply, current sensitive preamplifier, 500 MSPS/12-Bit ADC (Analog-to-Digital Converter), readout module based on ZYNQ SoC (System on Chip), power over Ethernet, and user interface circuits are stacked with board-to-board connectors. The system can achieve 4.6% gamma-ray energy resolution at 662 keV with a 20-{\mu}s pulse integral and PSD figure-of-merit of ~3.0 for the whole energy of neutrons and gamma-rays. This integrated digitizer base can also be interfaced with other detectors with a PMT.

Explore related subjects

Keep this discovery

BibTeXRIS

Tao Xue, Jinfu Zhu, Guanghua Gong, Liangjun Wei, Jianmin Li. 2018-06-23. Preliminary Design of Integrated Digitizer Base for Photomultiplier Tube. https://doi.org/10.1109/tns.2019.2918439

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det