SearcharxivSearch

arXiv subjects

Thanh-An Pham

Publications and source records attributed to Thanh-An Pham.

5 recordsLinked to original sources

ProDock: From multi-target consensus docking into database-backed storage

Protein--ligand docking is widely used in structure-based discovery, but routine studies often fail at the workflow level rather than at the scoring level. Receptor cleaning, ligand preparation, file conversion, box definition, run organization, and downstream parsing are frequently handled by fragmented scripts, which reduces reproducibility, obscures provenance, and complicates comparative analysis across targets, ligands, and docking settings. We present ProDock, an open-source Python toolkit for reproducible protein--ligand docking and postprocessing. ProDock organizes application-oriented docking into four connected layers: receptor and ligand preprocessing, provenance-aware docking execution, postprocessing of poses and interaction fingerprints, and SQLite-backed storage for later querying. The package supports inputs ranging from PDB identifiers and local receptor files to \texttt{SMILES} strings and prepared ligand directories, and integrates receptor preparation, ligand preparation, reference-ligand-based box generation, campaign serialization, batch docking, pose crawling, score extraction, interaction profiling, and database insertion within a consistent project-local workflow. By representing studies as explicit many-to-many campaigns linking multiple receptors, ligands, and docking backends, ProDock converts fragmented engine-specific outputs into structured analytical results that are easier to compare, reuse, and audit. ProDock is implemented in Python and released under an open-source license at https://github.com/Medicine-Artificial-Intelligence/ProDock. Documentation is available at https://prodock.readthedocs.io/en/latest.

q-bio.QM

Mechanical Artifacts in Optical Projection Tomography: Classification and Automatic Calibration

Optical projection tomography (OPT) is a powerful tool for biomedical studies. It achieves 3D visualization of mesoscopic biological samples with high spatial resolution using conventional tomographic-reconstruction algorithms. However, various artifacts degrade the quality of the reconstructed images due to experimental imperfections in the OPT instruments. While many efforts have been made to characterize and correct for these artifacts, they focus on one specific type of artifacts. This work has two contributions. First, we systematically document a catalog of mechanical artifacts based on a 3D description of the imaging system that uses a set of angular and translational parameters. Then, we introduce a calibration algorithm that recovers the unknown system parameters fed into the final 3D iterative reconstruction algorithm for a distortion-free volumetric image. Simulations with beads data and experimental results on a fluorescent textile fiber confirm that our algorithm successfully removes miscalibration artifacts in the reconstruction.

cs.CV

Optical Diffraction Tomography Meets Fluorescence Localization Microscopy

We show that structural information can be extracted from single molecule localization microscopy (SMLM) data. More precisely, we reinterpret SMLM data as the measures of a phaseless optical diffraction tomography system for which the illumination sources are fluorophores within the sample. Building upon this model, we propose a joint optimization framework to estimate both the refractive index map and the position of fluorescent molecules from the sole SMLM frames.

eess.SP

Method for Assessing the Fidelity of Optical Diffraction Tomography Reconstruction Methods

We use a spatial light modulator in a diffraction tomographic system to assess the accuracy of different refractive index reconstruction algorithms. Optical phase conjugation principles through complex media, allows us to quantify the error for different refractive index reconstruction algorithms without access to the ground truth. To our knowledge, this is the first assessment technique that uses structured illumination experimentally to test the accuracy of different reconstruction schemes.

physics.optics

Efficient Inversion of Multiple-Scattering Model for Optical Diffraction Tomography

Optical diffraction tomography relies on solving an inverse scattering problem governed by the wave equation. Classical reconstruction algorithms are based on linear approximations of the forward model (Born or Rytov), which limits their applicability to thin samples with low refractive-index contrasts. More recent works have shown the benefit of adopting nonlinear models. They account for multiple scattering and reflections, improving the quality of reconstruction. To reduce the complexity and memory requirements of these methods, we derive an explicit formula for the Jacobian matrix of the nonlinear Lippmann-Schwinger model which lends itself to an efficient evaluation of the gradient of the data- fidelity term. This allows us to deploy efficient methods to solve the corresponding inverse problem subject to sparsity constraints.

cs.CE