SearcharxivSearch

arXiv subjects

Thomas Browder

Publications and source records attributed to Thomas Browder.

7 recordsLinked to original sources

Migration of Belle II TOP Feature Extraction from the Zynq Processing System to PCIe40 Readout PCs

The Belle II Time-of-Propagation (TOP) detector is a key system for charged-particle identification (PID). Although TOP operated successfully during initial Belle II data taking, increasing luminosity and beam-induced background led to more frequent single-event upsets (SEUs) in the radiation-exposed Zynq systems-on-chip (SoCs). Resulting lockups of the embedded processing systems (PSs) interrupted data acquisition. To mitigate this limitation, waveform feature extraction, a critical task of the on-detector Zynq PS, was migrated to the off-detector PCIe40 readout PCs (ROPCs). The new architecture bypasses the PS in the event data path and performs feature extraction outside the detector radiation environment. This change removed SEU-induced PS lockups from the event data path and enabled stable operation of the TOP front-end electronics and the Belle II data-acquisition system under increased luminosity and background conditions. The typical TOP deadtime decreased from about 1% to a level consistent with zero after the final firmware patch, and stable operation was demonstrated at a Level-1 (L1) trigger rate of 30 kHz with a microchannel-plate photomultiplier-tube (MCP-PMT) hit rate of approximately 5 MHz per PMT. This paper describes the migrated architecture, its deployment and validation, and its operational and PID performance.

physics.ins-det

The Imaging Time-of-Propagation Detector at Belle II

We report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB $e^+e^-$ collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/$c$. To date, the detector has been used to record and analyze almost 600 fb$^{-1}$ of Belle II data.

hep-ex

A new tool to search for physics beyond the Standard Model in ${\bar B}\to D^{*+}\ell^- {\bar\nu}$

Recent experimental results in $B$ physics from Belle, BaBar and LHCb suggest new physics (NP) in the weak $b\to c$ charged-current and the $b\to s$ neutral-current processes. Here we focus on the charged-current case and specifically on the decay modes $B\to D^{*+}\ell^- \bar{\nu}$ with $\ell = e, \mu,$ and $\tau$. The world averages of the ratios $R_D$ and $R_D^{*}$ currently differ from the Standard Model (SM) by $3.4\sigma$ while $\Delta A_{FB} = A_{FB}(B\to D^{*} \mu\nu) - A_{FB} (B\to D^{*} e \nu)$ is found to be $4.1\sigma$ away from the SM prediction in an analysis of 2019 Belle data. These intriguing results suggest an urgent need for improved simulation and analysis techniques in $B\to D^{*+}\ell^- \bar{\nu}$ decays. Here we describe a Monte Carlo Event-generator tool based on EVTGEN developed to allow simulation of the NP signatures in $B\to D^*\ell^- \nu$, which arise due to the interference between the SM and NP amplitudes. As a demonstration of the proposed approach, we exhibit some examples of NP couplings that are consistent with current data and could explain the $\Delta A_{FB}$ anomaly in $B\to D^*\ell^- \nu$ while remaining consistent with other constraints. We show that the $\Delta$-type observables such as $\Delta A_{FB}$ and $\Delta S_5$ eliminate most QCD uncertainties from form factors and allow for clean measurements of NP. We introduce correlated observables that improve the sensitivity to NP. We discuss prospects for improved observables sensitive to NP couplings with the expected 50 ab$^{-1}$ of Belle II data, which seems to be ideally suited for this class of measurements.

hep-ph

Measurements of Beam Backgrounds in SuperKEKB Phase 2

The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgro\ unds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle~II experi\ ment. We report on the first background measurements performed after roll-in of the Belle II detector, a period known as SuperKE\ KB Phase 2, utilizing both the BEAST II system of dedicated background detectors and the Belle II detector itself. We also repor\ t on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions f\ rom synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds origina\ ting from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV elect\ ron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds for\ ward and conclude it is safe to install the Belle II vertex detector.

physics.ins-det

Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB electron-positron collider. The purpose of the detector is to identify the type of charged hadrons produced in electron-positron collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-capacitor array application-specific integrated circuits. The processes of triggering, digitization of windows of interest, readout, and data transfer to the Belle II data acquisition system are managed by Xilinx Zynq-7000 programmable system on a chip devices.

physics.ins-det

Physics Achievements from the Belle Experiment

The Belle experiment, running at the KEKB e+e- asymmetric energy collider during the first decade of the century, achieved its original objective of measuring precisely differences between particles and anti-particles in the B system. After collecting 1000 fb-1 of data at various Upsilon resonances, Belle also obtained the many other physics results described in this article.

hep-ex

Status Report of the DPHEP Study Group: Towards a Global Effort for Sustainable Data Preservation in High Energy Physics

Data from high-energy physics (HEP) experiments are collected with significant financial and human effort and are mostly unique. An inter-experimental study group on HEP data preservation and long-term analysis was convened as a panel of the International Committee for Future Accelerators (ICFA). The group was formed by large collider-based experiments and investigated the technical and organisational aspects of HEP data preservation. An intermediate report was released in November 2009 addressing the general issues of data preservation in HEP. This paper includes and extends the intermediate report. It provides an analysis of the research case for data preservation and a detailed description of the various projects at experiment, laboratory and international levels. In addition, the paper provides a concrete proposal for an international organisation in charge of the data management and policies in high-energy physics.

hep-ex