SearcharxivSearch

arXiv subjects

Thomas J. Roberts

Publications and source records attributed to Thomas J. Roberts.

8 recordsLinked to original sources

Rastreo muscular móvil usando magnetomicrometría -- traducción al español del articulo "Untethered Muscle Tracking Using Magnetomicrometry" por el autor Cameron R. Taylor

Muscle tissue drives nearly all movement in the animal kingdom, providing power, mobility, and dexterity. Technologies for measuring muscle tissue motion, such as sonomicrometry, fluoromicrometry, and ultrasound, have significantly advanced our understanding of biomechanics. Yet, the field lacks the ability to monitor muscle tissue motion for animal behavior outside the lab. Towards addressing this issue, we previously introduced magnetomicrometry, a method that uses magnetic beads to wirelessly monitor muscle tissue length changes, and we validated magnetomicrometry via tightly-controlled in situ testing. In this study we validate the accuracy of magnetomicrometry against fluoromicrometry during untethered running in an in vivo turkey model. We demonstrate real-time muscle tissue length tracking of the freely-moving turkeys executing various motor activities, including ramp ascent and descent, vertical ascent and descent, and free roaming movement. Given the demonstrated capacity of magnetomicrometry to track muscle movement in untethered animals, we feel that this technique will enable new scientific explorations and an improved understanding of muscle function. -- -- El tejido muscular es el motor de casi todos los movimientos del reino animal, ya que proporciona fuerza, movilidad y destreza. Las tecnologías para medir el movimiento del tejido muscular, como la sonomicrometría, la fluoromicrometría y el ultrasonido, han avanzado considerablemente la comprensión de la biomecánica. Sin embargo, este campo carece de la capacidad de rastrear el movimiento del tejido muscular en el comportamiento animal fuera del laboratorio. Para abordar este problema, presentamos previamente la magnetomicrometría, un método que utiliza pequeños imanes para rastrear de forma inalámbrica los cambios de longitud del tejido muscular, y validamos la magnetomicrometría mediante pruebas estrechamente controladas in situ. En este estudio validamos la precisión de la magnetomicrometría en comparación con la fluoromicrometría usando un modelo de pavo in vivo mientras corre libremente. Demostramos el rastreo en tiempo real de la longitud del tejido muscular de los pavos que se mueven libremente ejecutando varias actividades motoras, incluyendo el ascenso y el descenso en rampa, el ascenso y el descenso vertical, y el movimiento libre. Dada la capacidad demostrada de la magnetomicrometría para rastrear el movimiento muscular en animales en un contexto móvil, creemos que esta técnica permitirá nuevas exploraciones científicas y una mejor comprensión de la función muscular.

physics.med-ph

Studying Antimatter Gravity with Muonium

The gravitational acceleration of antimatter, gbar, has yet to be directly measured; an unexpected outcome of its measurement could change our understanding of gravity, the universe, and the possibility of a fifth force. Three avenues are apparent for such a measurement: antihydrogen, positronium, and muonium, the last requiring a precision atom interferometer and novel muonium beam under development. The interferometer and its few-picometer alignment and calibration systems appear feasible. With 100 nm grating pitch, measurements of gbar to 10%, 1%, or better can be envisioned. These could constitute the first gravitational measurements of leptonic matter, of 2nd-generation matter, and possibly, of antimatter.

physics.ins-det

Progress Towards a Muonium Gravity Experiment

The gravitational acceleration of antimatter, $\bar g$, has yet to be directly measured but could change our understanding of gravity, the Universe, and the possibility of a fifth force. Three avenues are apparent for such a measurement: antihydrogen, positronium, and muonium, the last requiring a precision atom interferometer and benefiting from a novel muonium beam under development. The interferometer and its few-picometer alignment and calibration systems appear to be feasible. With 100 nm grating pitch, measurements of $\bar g$ to 10%, 1%, or better can be envisioned. This could constitute the first gravitational measurement of leptonic matter, of second-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

physics.ins-det

MuSim, a graphical user interface for multiple simulation programs

MuSim is a new user-friendly program designed to interface to many different particle simulation codes, regardless of their data formats or geometry descriptions. It presents the user with a compelling graphical user interface that includes a flexible 3-D view of the simulated world plus powerful editing and drag-and-drop capabilities. All aspects of the design can be parameterized so that parameter scans and optimizations are easy. It is simple to create plots and display events in the 3-D viewer (with a slider to vary the transparency of solids), allowing for an effortless comparison of different simulation codes. Simulation codes: G4beamline 3.02 and MCNP 6.1; more are coming. Many accelerator design tools and beam optics codes were written long ago, with primitive user interfaces by today's standards. MuSim is specifically designed to make it easy to interface to such codes, providing a common user experience for all, and permitting the construction and exploration of models with very little overhead. For today's technology-driven students, graphical interfaces meet their expectations far better than text based tools, and education in accelerator physics is one of our primary goals.

physics.acc-ph

Measuring Antimatter Gravity with Muonium

The gravitational acceleration of antimatter, $\bar{g}$, has never been directly measured and could bear importantly on our understanding of gravity, the possible existence of a fifth force, and the nature and early history of the universe. Only two avenues for such a measurement appear to be feasible: antihydrogen and muonium. The muonium measurement requires a novel, monoenergetic, low-velocity, horizontal muonium beam directed at an atom interferometer. The precision three-grating interferometer can be produced in silicon nitride or ultrananocrystalline diamond using state-of-the-art nanofabrication. The required precision alignment and calibration at the picometer level also appear to be feasible. With 100 nm grating pitch, a 10% measurement of $\bar{g}$ can be made using some months of surface-muon beam time, and a 1% or better measurement with a correspondingly larger exposure. This could constitute the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

physics.ins-det

Measuring Antimatter Gravity with Muonium

We consider a measurement of the gravitational acceleration of antimatter, gbar, using muonium. A monoenergetic, low-velocity, horizontal muonium beam will be formed from a surface-muon beam using a novel technique and directed at an atom interferometer. The measurement requires a precision three-grating interferometer: the first grating pair creates an interference pattern which is analyzed by scanning the third grating vertically using piezo actuators. State-of-the-art nanofabrication can produce the needed membrane grating structure in silicon nitride or ultrananoscrystalline diamond. With 100 nm grating pitch, a 10% measurement of gbar can be made using some months of surface-muon beam time. This will be the first gravitational measurement of leptonic matter, of 2nd-generation matter and, possibly, the first measurement of the gravitational acceleration of antimatter.

physics.ins-det

Study of multiple scattering in high magnetic fields

Muon cooling for a neutrino factory or muon collider can be achieved using low-Z absorbers in strong focusing fields. Proposed cooling lattices place absorbers in solenoidal fields ranging up to 30 to 40T. The cooling performance of these lattices is determined by the interplay of ionization energy loss and Moliere scattering, but Bethe's classic treatment of Moliere scattering ignores the helical motion of charged particles in solenoidal fields. When this motion is taken into account, the performance of these lattices can be better than predicted by simulations using the standard treatment.

physics.acc-ph

An Explanation of Dayton Miller's Anomalous "Ether Drift" Result

In 1933 Dayton Miller published in this journal the results of his voluminous observations using his ether drift interferometer, and proclaimed that he had determined the "absolute motion of the earth". This result is in direct conflict with the prediction of Special Relativity, and also with numerous related experiments that found no such signal or "absolute motion". This paper presents a complete explanation for his anomalous result by: a) showing that his results are not statistically significant, b) describing in detail how flaws in his analysis procedure produced a false signal with precisely the properties he expected, and c) presenting a quantitative model of his systematic drift that shows there is no real signal in his data. In short, this is every experimenter's nightmare: he was unknowingly looking at statistically insignificant patterns in his systematic drift that mimicked the appearance of a real signal. An upper limit on "absolute motion" of 6 km/sec is derived from his raw data, fully consistent with similar experimental results and the prediction of Special Relativity. The key point of this paper is the need for a comprehensive and quantitative error analysis. The concepts and techniques used in this analysis were not available in Miller's day, but are now standard. These problems also apply to the famous measurements of Michelson and Morley, and to most if not all similar experiments; appendices are provided discussing several such experiments.

physics.class-ph