Rastreo muscular m\'ovil usando magnetomicrometr\'ia -- traducci\'on al espa\~nol del articulo "Untethered Muscle Tracking Using Magnetomicrometry" por el autor Cameron R. Taylor

Abstract

Muscle tissue drives nearly all movement in the animal kingdom, providing power, mobility, and dexterity. Technologies for measuring muscle tissue motion, such as sonomicrometry, fluoromicrometry, and ultrasound, have significantly advanced our understanding of biomechanics. Yet, the field lacks the ability to monitor muscle tissue motion for animal behavior outside the lab. Towards addressing this issue, we previously introduced magnetomicrometry, a method that uses magnetic beads to wirelessly monitor muscle tissue length changes, and we validated magnetomicrometry via tightly-controlled in situ testing. In this study we validate the accuracy of magnetomicrometry against fluoromicrometry during untethered running in an in vivo turkey model. We demonstrate real-time muscle tissue length tracking of the freely-moving turkeys executing various motor activities, including ramp ascent and descent, vertical ascent and descent, and free roaming movement. Given the demonstrated capacity of magnetomicrometry to track muscle movement in untethered animals, we feel that this technique will enable new scientific explorations and an improved understanding of muscle function. -- -- El tejido muscular es el motor de casi todos los movimientos del reino animal, ya que proporciona fuerza, movilidad y destreza. Las tecnolog\'ias para medir el movimiento del tejido muscular, como la sonomicrometr\'ia, la fluoromicrometr\'ia y el ultrasonido, han avanzado considerablemente la comprensi\'on de la biomec\'anica. Sin embargo, este campo carece de la capacidad de rastrear el movimiento del tejido muscular en el comportamiento animal fuera del laboratorio. Para abordar este problema, presentamos previamente la magnetomicrometr\'ia, un m\'etodo que utiliza peque\~nos imanes para rastrear de forma inal\'ambrica los cambios de longitud del tejido muscular, y validamos la magnetomicrometr\'ia mediante pruebas estrechamente controladas in situ. En este estudio validamos la precisi\'on de la magnetomicrometr\'ia en comparaci\'on con la fluoromicrometr\'ia usando un modelo de pavo in vivo mientras corre libremente. Demostramos el rastreo en tiempo real de la longitud del tejido muscular de los pavos que se mueven libremente ejecutando varias actividades motoras, incluyendo el ascenso y el descenso en rampa, el ascenso y el descenso vertical, y el movimiento libre. Dada la capacidad demostrada de la magnetomicrometr\'ia para rastrear el movimiento muscular en animales en un contexto m\'ovil, creemos que esta t\'ecnica permitir\'a nuevas exploraciones cient\'ificas y una mejor comprensi\'on de la funci\'on muscular.

Explore related subjects

Keep this discovery

BibTeXRIS

Cameron R. Taylor, Seong Ho Yeon, William H. Clark, Ellen G. Clarrissimeaux, Mary Kate O'Donnell, Thomas J. Roberts, Hugh M. Herr. 2022-11-19. Rastreo muscular m\'ovil usando magnetomicrometr\'ia -- traducci\'on al espa\~nol del articulo "Untethered Muscle Tracking Using Magnetomicrometry" por el autor Cameron R. Taylor. https://doi.org/10.3389/fbioe.2022.1010275

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Phase-contrast micro-CT for intra-operative breast tumour margin assessment using a microfocus x-ray source and photon-counting detector

Objective: Intra-operative tumour margin assessment during breast-conserving surgery requires rapid, high-resolution imaging of excised tissue, allowing the surgical team to take appropriate action within a single operation. This study evaluates a custom propagation-based phase-contrast micro-computed tomography (micro-CT) system designed to meet these clinical constraints without specialised optical elements. Methods: The experimental setup pairs a microfocus x-ray source with a photon-counting detector in a cone-beam geometry. We explore how the spatial coherence of the source can provide propagation-based phase contrast -- with no additional specialised optical elements -- and balance this against maximising the x-ray flux of the cone-beam geometry. System performance was evaluated across two anode target materials and filtration configurations at various tube power settings. Imaging capabilities were validated using anthropomorphic breast tissue phantoms and a formalin-fixed paraffin-embedded (FFPE) breast tissue specimen, with reconstructions compared against gold-standard histology. Results: An unfiltered tungsten target operated at 40 kVp yielded optimal image quality. The optimised system achieved high-resolution CT reconstructions of a 5 cm diameter sample with an isotropic voxel size of 40.7 $\upmu\text{m}$ in a scan time of 12 minutes. Reconstructed volumes demonstrated strong visual correlation with corresponding histology slides. Conclusion: Combining a microfocus source with a photon-counting detector enables high-resolution, phase-contrast micro-CT within a clinically viable timeframe, demonstrating strong potential for intra-operative margin assessment.

physics.med-ph

Understanding Search and Decision Errors in Liver Metastasis Detection and the Effects of Lower Radiation Dose

The detection performance of liver metastases decreases with the reduction of radiation dose, but misses are heterogeneous. Previous eye tracking work has characterized missed metastases into two categories: search errors i.e., the eyes never land on the lesion, and decision errors i.e., the lesion is seen but not recognized as malignant. We integrated three prior reader studies to answer this question. In all studies, radiologists interpreted the same set of 40 contrast enhanced abdominal CT exams containing 91 liver metastases whose locations had been previously marked. In two studies, the workstation recorded their gaze and eye movements. Using eye dwell times, metastases were classified as search-error-dominant (majority of misses had <2 sec gaze time) or decision-error-dominant (>2 sec gaze time). In the third study, exams were interpreted both at 120 and 200 quality reference mAs (QRM) by ten radiologists. The third study did not include eye tracking. Out of 91 liver metastases, we excluded 16 that were never missed in the eye tracking studies and used 75 liver metastases for the present study.

physics.med-ph

Develop and Optimize 5DCT Imaging Simulation and Reconstruction Methods

Purpose: To develop and optimize a 5DCT (3D + cardiac phase + respiratory phase) imaging simulation and reconstruction pipeline, and to compare two sinogram-space interpolation methods for reconstructing images at arbitrary combinations of cardiac and respiratory phase. Methods: Helical CT projections were simulated from the 4D XCAT phantom across a range of cardiac and respiratory motion states, with Poisson and electronic noise added. Ground-truth-matched volumes were generated at 5 cardiac phases and 10 respiratory amplitudes (50 total phase combinations). Because acquired projections are sparsely and unevenly distributed across this joint phase space, each target slice was reconstructed by interpolating rebinned sinogram rows to the target cardiac phase and respiratory amplitude, using either 2D scattered barycentric interpolation or 2D scattered local linear interpolation with a circular kernel for cardiac phase. Reconstructed volumes were compared to phantom ground truth using mean absolute error (MAE), and to conventional respiratory-gated 4DCT (r4DCT) reconstructed from the same simulated data. Results: Both interpolation methods eliminated the severe axial misalignment artifacts present when helical projections were reconstructed without phase-space interpolation. Local linear interpolation achieved lower MAE than barycentric interpolation across most tested conditions, with the largest improvement at low pitch. The 5DCT pipeline also produced respiratory-only volumes with fewer residual cardiac-motion artifacts than conventional r4DCT reconstructed from the same projection data, including at standard clinical pitch (0.1). Conclusions: 5DCT reconstruction using sinogram-space interpolation is feasible and can jointly resolve cardiac and respiratory motion with better accuracy than conventional 4DCT reconstruction.