SearcharxivSearch

arXiv subjects

Timothy S. Read

Publications and source records attributed to Timothy S. Read.

2 recordsLinked to original sources

High-Resolution Atomic Magnetometer-Based Imaging of Integrated Circuits and Batteries

Optically pumped magnetometers (OPMs) have emerged as a powerful technique for high-resolution magnetic field imaging. However, achieving sub-millimeter spatial resolution at sub-picotesla sensitivities ($\mathrm{< 1\,pT/\sqrt{Hz}}$) remains challenging, particularly under finite-field conditions. We present a high-resolution magnetic imaging system based on a free-induction-decay (FID) OPM integrated with a two-axis scanning micromirror for automated beam steering. The double-pass optical configuration allows millimeter-scale devices under test (DUTs) to be positioned directly behind the vapor cell. This enables a standoff distance of 2.7 mm between the magnetic source and the atomic vapor, improving practical imaging resolution by increasing the amplitude of near-field magnetic signals sampled within the sensitive volume. Spatial resolution is experimentally demonstrated by imaging a custom printed circuit board (PCB) containing antiparallel copper tracks spaced 2 mm apart, with measured field maps in close agreement with Biot-Savart predictions. The OPM achieves an optimal field sensitivity of $\mathrm{0.5\,pT/\sqrt{Hz}}$, demonstrating the system's capability for high-precision magnetic field measurements. The imaging system is further validated by resolving polarity-dependent asymmetries in a bridge rectifier integrated circuit (IC) and tracking current dynamics in a ceramic battery in situ. These results highlight the potential of OPM-based systems for noninvasive diagnostics of electronic circuits and batteries.

physics.atom-ph

A Four-channel Optically Pumped Magnetometer for a Magnetoencephalography Sensor Array

We present a novel four-channel OPM sensor for magnetoencephalography that utilizes a two-color pump/probe scheme on a single optical axis. We characterize its performance across 18 built sensor modules. The new sensor implements several improvements over our previously developed sensor including lower vapor-cell operating temperature, improved probe-light detection optics, and reduced optical power requirements. The sensor also has new electromagnetic field coils on the sensor head which are designed using stream-function-based current optimization. We detail the coil design methodology and present experimental characterization of the coil performance. The magnetic sensitivity of the sensor is on average 12.3 fT/rt-Hz across the 18 modules while the average gradiometrically inferred sensitivity is about 6.0 fT/rt-Hz. The sensor 3-dB bandwidth is 100 Hz on average. The on-sensor coil performance is in good agreement with the simulations.

physics.med-ph