SearcharxivSearch

arXiv subjects

Tobias Bothwell

Publications and source records attributed to Tobias Bothwell.

17 recordsLinked to original sources

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-ph

Sub-Doppler laser cooling and optical transport of cesium with static magnetic fields

Laser cooling of alkali atoms typically requires time-varying magnetic fields, introducing unwanted coupling between atom preparation and coherent operations. Here we demonstrate sub-Doppler laser cooling and optical transport of alkali atoms in a fully static magnetic-field configuration. Using a blue-detuned Type-II magneto-optical trap (MOT) operating on the closed $F=3 \rightarrow F'=2$ transition of the D2 line in cesium, we achieve temperatures of 17(1) $μ$K without changing the magnetic-field gradient between cooling stages. This enables direct loading into a shallow optical lattice and transport over 17 cm within the same static-field environment. In contrast to conventional alkali cooling schemes with dynamic fields, our approach establishes a continuous cooling and transport protocol compatible with static-field platforms. These results validate Type-II cooling as a practical technique for alkali atoms and provide a new route toward continuous-operation architectures in sensing and quantum computing.

physics.atom-ph

Demonstration of a Logical Architecture Uniting Motion and In-Place Entanglement

We demonstrate a logical neutral atom architecture that integrates atom motion with in-place entanglement to achieve lower overheads than entangling-zone approaches. Using a 114-qubit device, we perform three proof-of-principle logical-qubit experiments. First, we implement a pre-compiled, non-scalable variant of Shor's algorithm, observing improved logical-over-physical performance, including with loss correction and leakage detection, achieving up to a 2x reduction in TVD. Second, we construct constant-depth logical CX ladders; on current hardware these execute with serial entangling operations, yet still yield 2-4x lower error for 8 and 12 logical qubits. Third, we prepare the [[16,4,4]] code and perform single-round decoding with post-processed error correction, achieving 8x improvement on logical vs physical. These results demonstrate how combining motion with in-place entanglement offers lower overhead than entangling-zone approaches.

quant-ph

Cryogenic Optical Lattice Clock with $1.7\times 10^{-20}$ Blackbody Radiation Stark Uncertainty

Controlling the Stark perturbation from ambient thermal radiation is key to advancing the performance of many atomic frequency standards, including state-of-the-art optical lattice clocks (OLCs). We demonstrate a cryogenic OLC that utilizes a dynamically actuated radiation shield to control the perturbation at $1.7\times10^{-20}$ fractional frequency, a factor of $\sim$40 beyond the best OLC to date. Our shield furnishes the atoms with a near-ideal cryogenic blackbody radiation (BBR) environment by rejecting external thermal radiation at the part-per-million level during clock spectroscopy, overcoming a key limitation with previous cryogenic BBR control solutions in OLCs. While the lowest BBR shift uncertainty is realized with cryogenic operation, we further exploit the radiation control that the shield offers over a wide range of temperatures to directly measure and verify the leading BBR Stark dynamic correction coefficient for ytterbium. This independent measurement reduces the literature-combined uncertainty of this coefficient by 30%, thus benefiting state-of-the-art Yb OLCs operated at room temperature. We verify the static BBR coefficient for Yb at the low $10^{-18}$ level.

physics.atom-ph

Deployment of a Transportable Yb Optical Lattice Clock

We report on the first deployment of a ytterbium (Yb) transportable optical lattice clock (TOLC), commercially shipping the clock 3,000 km from Boulder, Colorado to Washington DC. The system, composed of a rigidly mounted optical reference cavity, atomic physics package, and an optical frequency comb, fully realizes an independent frequency standard for comparisons in the optical and microwave domains. The shipped Yb TOLC was fully operational within 2 days of arrival, enabling frequency comparisons with rubidium (Rb) fountains at the United States Naval Observatory (USNO). To the best of our knowledge, this represents the first deployment of a fully independent TOLC, including the frequency comb, coherently uniting the optical stability of the Yb TOLC to the microwave output of the Rb fountain.

physics.atom-ph

Lattice Light Shift Evaluations In a Dual-Ensemble Yb Optical Lattice Clock

In state-of-the-art optical lattice clocks, beyond-electric-dipole polarizability terms lead to a break-down of magic wavelength trapping. In this Letter, we report a novel approach to evaluate lattice light shifts, specifically addressing recent discrepancies in the atomic multipolarizability term between experimental techniques and theoretical calculations. We combine imaging and multi-ensemble techniques to evaluate lattice light shift atomic coefficients, leveraging comparisons in a dual-ensemble lattice clock to rapidly evaluate differential frequency shifts. Further, we demonstrate application of a running wave field to probe both the multipolarizability and hyperpolarizability coefficients, establishing a new technique for future lattice light shift evaluations.

physics.atom-ph

Ratchet Loading and Multi-Ensemble Operation in an Optical Lattice Clock

We demonstrate programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. The control is facilitated through a combination of spatial manipulation of the magneto-optical trap and atomic population shelving to a metastable state. We first employ the technique to load an extended (5 mm) atomic sample with uniform density in an optical lattice clock, reducing atomic interactions and realizing remarkable frequency homogeneity across the atomic cloud. We also prepare multiple spatially separated atomic ensembles and realize multi-ensemble clock operation within the standard one-dimensional (1D) optical lattice clock architecture. Leveraging this technique, we prepare two oppositely spin-polarized ensembles that are independently addressable, offering a platform for implementing spectroscopic protocols for enhanced tracking of local oscillator phase. Finally, we demonstrate a relative fractional frequency instability at one second of $2.4(1) \times10^{-17}$ between two ensembles, useful for characterization of intra-lattice differential systematics.

physics.atom-ph

Evaluation of lattice light shift at low 10$^{-19}$ uncertainty for a shallow lattice Sr optical clock

A Wannier-Stark optical lattice clock has demonstrated unprecedented measurement precision for optical atomic clocks. We present a systematic evaluation of the lattice light shift, a necessary next step for establishing this system as an accurate atomic clock. With precise control of the atomic motional states in the lattice, we report accurate measurements of the multipolar and the hyperpolar contributions and the operational lattice light shift with a fractional frequency uncertainty of 3.5$\times$10${}^{-19}$.

physics.atom-ph

Direct comparison of two spin squeezed optical clocks below the quantum projection noise limit

Building scalable quantum systems that demonstrate genuine performance enhancement based on entanglement is a major scientific goal for fields including computing, networking, simulations, and metrology. The tremendous challenge arises from the fragility of entanglement in increasingly larger sized quantum systems. Optical atomic clocks utilizing a large number of atoms have pushed the frontier of measurement science, building on precise engineering of quantum states and control of atomic interactions. However, today's state-of-the-art optical atomic clocks are limited by the quantum projection noise (QPN) defined by many uncorrelated atoms. Pioneering work on producing spin squeezed states of atoms has shown a path towards integrating entanglement into the best performing clocks. However, to directly demonstrate advantage of quantum entanglement in a working clock we must prevent backaction effects that degrade quantum coherence and introduce uncontrolled perturbations, as well as minimize the influence of technical noise arising from the interrogating clock laser. Here we present a new optical clock platform integrated with collective strong-coupling cavity QED for quantum non-demolition (QND) measurement. Optimizing the competition between spin measurement precision and loss of coherence, we measure a Wineland parameter of -1.8(7) dB for 1.9x10$^4$ atoms, thus verifying the presence of entanglement. Furthermore, a moving lattice allows the cavity to individually address two independent sub-ensembles, enabling us to spin squeeze two clock ensembles successively and compare their performance. This differential comparison between the two squeezed clocks directly verifies enhanced clock stability of 2.0(3) dB below QPN, and 0.6(3) dB above the standard quantum limit (SQL), at the measurement precision level of 10$^{-17}$, without subtracting any technical noise contributions.

quant-ph

Hamiltonian engineering of spin-orbit coupled fermions in a Wannier-Stark optical lattice clock

Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a powerful spin model realization. The relative strength of the on-site and off-site interactions can be tuned to achieve a zero density shift at a `magic' lattice depth. This mechanism, together with a large number of atoms, enables the demonstration of the most stable atomic clock while minimizing a key systematic uncertainty related to atomic density. Interactions can also be maximized by driving off-site Wannier-Stark transitions, realizing a ferromagnetic to paramagnetic dynamical phase transition.

physics.atom-ph

Resolving the gravitational redshift within a millimeter atomic sample

Einstein's theory of general relativity states that clocks at different gravitational potentials tick at different rates - an effect known as the gravitational redshift. As fundamental probes of space and time, atomic clocks have long served to test this prediction at distance scales from 30 centimeters to thousands of kilometers. Ultimately, clocks will study the union of general relativity and quantum mechanics once they become sensitive to the finite wavefunction of quantum objects oscillating in curved spacetime. Towards this regime, we measure a linear frequency gradient consistent with the gravitational redshift within a single millimeter scale sample of ultracold strontium. Our result is enabled by improving the fractional frequency measurement uncertainty by more than a factor of 10, now reaching 7.6$\times 10^{-21}$. This heralds a new regime of clock operation necessitating intra-sample corrections for gravitational perturbations.

physics.atom-ph

Optical Atomic Clock Comparison through Turbulent Air

We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.

physics.optics

Precision Metrology Meets Cosmology: Improved Constraints on Ultralight Dark Matter from Atom-Cavity Frequency Comparisons

We conduct frequency comparisons between a state-of-the-art strontium optical lattice clock, a cryogenic crystalline silicon cavity, and a hydrogen maser to set new bounds on the coupling of ultralight dark matter to Standard Model particles and fields in the mass range of $10^{-16}$ $-$ $10^{-21}$ eV. The key advantage of this two-part ratio comparison is the differential sensitivities to time variation of both the fine-structure constant and the electron mass, achieving a substantially improved limit on the moduli of ultralight dark matter, particularly at higher masses than typical atomic spectroscopic results. Furthermore, we demonstrate an extension of the search range to even higher masses by use of dynamical decoupling techniques. These results highlight the importance of using the best performing atomic clocks for fundamental physics applications as all-optical timescales are increasingly integrated with, and will eventually supplant, existing microwave timescales.

physics.atom-ph

Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks

Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.

physics.atom-ph

Demonstration of a time scale based on a stable optical carrier

We demonstrate a time scale based on a phase stable optical carrier that accumulates an estimated time error of $48\pm94$ ps over 34 days of operation. This all-optical time scale is formed with a cryogenic silicon cavity exhibiting improved long-term stability and an accurate $^{87}$Sr lattice clock. We show that this new time scale architecture outperforms existing microwave time scales, even when they are steered to optical frequency standards. Our analysis indicates that this time scale is capable of reaching a stability below $1\times10^{-17}$ after a few months of averaging, making timekeeping at the $10^{-18}$ level a realistic prospect.

physics.atom-ph

JILA SrI Optical Lattice Clock with Uncertainty of $2.0 \times 10^{-18}$

We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to average to its systematic uncertainty in under 10 minutes. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the Boulder Area Clock Optical Network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.

physics.atom-ph

Collective atomic scattering and motional effects in a dense coherent medium

We investigate collective emission from coherently driven ultracold $ ^{88} $ Sr atoms. We perform two sets of experiments, using a strong and weak transition that are insensitive and sensitive, respectively, to atomic motion at one microKelvin. We observe highly directional forward emission with a peak intensity that is enhanced, for the strong transition, by > $ 10 ^3 $ compared to that in the transverse direction. This is accompanied by substantial broadening of spectral lines. For the weak transition, the forward enhancement is substantially reduced due to motion. Meanwhile, a density-dependent frequency shift of the weak transition (~10% of the natural linewidth) is observed. In contrast, this shift is suppressed to <1% of the natural linewidth for the strong transition. Along the transverse direction, we observe strong polarization dependences of the fluorescence intensity and line broadening for both transitions. The measurements are reproduced with a theoretical model treating the atoms as coherent, interacting, radiating dipoles.

physics.atom-ph