SearcharxivSearch

arXiv subjects

U. Frankenfeld

Publications and source records attributed to U. Frankenfeld.

12 recordsLinked to original sources

Demonstrating CBM Capabilities by $Λ$ Baryon Reconstruction in Ni+Ni Collisions with the mCBM Experiment at SIS18 of GSI/FAIR

The Compressed Baryonic Matter (CBM) experiment at the upcoming Facility for Antiproton and Ion Research (FAIR) is a high-rate fixed-target experiment designed to investigate nuclear matter at extreme baryon densities in relativistic nucleus-nucleus collisions. To enable high-statistics measurements of rare probes, CBM is designed to operate at event rates up to 10 MHz. This necessitates the development of fast and radiation-tolerant detectors, self-triggered front-end electronics, a free-streaming data acquisition architecture, and real-time event reconstruction capabilities. Prototype versions and pre-series productions of the CBM detector systems have been deployed in the mini-CBM demonstrator setup mCBM - an experimental precursor comprising sub-components of all major CBM systems, installed at the SIS18 facility of GSI/FAIR within the FAIR Phase-0 program. In 2024, Ni+Ni collisions at a kinetic beam energy of 1.93 AGeV and an average interaction rate of about 250 kHz were successfully recorded. This dataset enables a detailed evaluation of the operational performance of the detector systems as well as the complete CBM data chain, while the reconstruction of rare $Λ$ baryons serves as a natural benchmark. This paper presents the first results on $Λ$ signal reconstruction with the mCBM experiment, demonstrating the readiness of the detector technologies and the data chain for the upcoming full-scale CBM experiment.

physics.ins-det

Minimal material, maximum coverage: Silicon Tracking System for high-occupancy conditions

Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector designed for high-occupancy environments ($\leq$ 10 MHz/cm$^2$). To achieve this, we employ Double-Sided Double Metal (DSDM) silicon microstrip sensors, coupled with readout electronics capable of precise timing and energy measurements. These 320 $μ$m thick sensors, featuring $2\times 1024$ channels with a 58 $μ$m pitch, are connected via ultra-lightweight aluminium-polyimide microcables for signal transmission and integrated with a custom SMX readout ASIC, operating in free-streaming mode. This system enables the simultaneous measurement of time ($Δt \simeq 5$~ns) and charge deposition (0.1-100 fC), significantly enhancing the detector's capacity for high-precision track reconstruction in high-occupancy and harsh radiation field environments. The primary application of this technology is the Silicon Tracking System (STS) for the CBM experiment, with additional potential in projects like the J-PARC E16 experiment and future uses in medical physics, such as advanced imaging telescopes. In this contribution, we present the current status of CBM STS construction, with almost one-third of the modules produced and tested. We also discuss immediate applications and explore promising prospects in both scientific and medical fields.

physics.ins-det

From 3D to 5D tracking: SMX ASIC-based Double-Sided Micro-Strip detectors for comprehensive space, time, and energy measurements

We present the recent development of a lightweight detector capable of accurate spatial, timing, and amplitude resolution of charged particles. The technology is based on double-sided double-metal p+\,--\,n\,--\,n+ micro-strip silicon sensors, ultra-light long aluminum-polyimide micro-cables for the analogue signal transfer, and a custom-developed SMX read-out ASIC capable of measurement of the time ($Δt \lesssim 5 \,\mathrm{ns}$) and amplitude. Dense detector integration enables a material budget $>0.3\,\% X_0$. A sophisticated powering and grounding scheme keeps the noise under control. In addition to its primary application in Silicon Tracking System of the future CBM experiment in Darmstadt, our detector will be utilized in other research applications.

physics.ins-det

Spark probability measurement of a single mask triple GEM detector

Triple Gas Electron Multiplier (GEM) detectors will be used as a tracking device in the first two stations of CBM MUon CHamber (MUCH), where the maximum particle rate is expected to reach ~1 MHz/cm2 for central Au-Au collisions at 8 AGeV. Therefore, the stable operation of the detector is very important. Discharge probability has been measured of a single mask triple GEM detector at the CERN SPS/H4 beam-line facility with a pion beam of ~150 GeV/c and also in an environment of highly ionizing shower particles. The spark probability as a function of gain has been studied for different particle rates. The details of the experimental setup, method of spark identification and results are presented in this paper.

physics.ins-det

The upgrade of the ALICE TPC with GEMs and continuous readout

The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous readout electronics based on the SAMPA chip, an ALICE development, are replacing the previous elements. The construction of these new elements, together with their associated quality control procedures, is explained in detail. Finally, the readout chamber and front-end electronics cards replacement, together with the commissioning of the detector prior to installation in the experimental cavern, are presented. After a nine-year period of R&D, construction, and assembly, the upgrade of the TPC was completed in 2020.

physics.ins-det

High-Precision Contactless Optical 3D-Metrology of Silicon Sensors

We describe a setup and procedures for contactless optical 3D-metrology of silicon micro-strip sensors. Space points are obtained by video microscopy and a high precision XY-table. The XY-dimensions are obtained from the movement of the table and pattern recognition, while the Z-dimension results from a Fast Fourier Transformation analyses of microscopic images taken at various distances of the optical system from the object under investigation. The setup is employed to measure the position of silicon sensors mounted onto a carbon fibre structure with a precision of a few microns.

physics.ins-det

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In order to make full use of this luminosity, the currently used gated Multi-Wire Proportional Chambers will be replaced. The upgrade relies on continuously operated readout detectors employing Gas Electron Multiplier technology to retain the performance in terms of particle identification via the measurement of the specific energy loss by ionization d$E$/d$x$. A full-size readout chamber prototype was assembled in 2014 featuring a stack of four GEM foils as an amplification stage. The performance of the prototype was evaluated in a test beam campaign at the CERN PS. The d$E$/d$x$ resolution complies with both the performance of the currently operated MWPC-based readout chambers and the challenging requirements of the ALICE TPC upgrade program. Detailed simulations of the readout system are able to reproduce the data.

physics.ins-det

Systematic measurements of the gain and the energy resolution of single and double mask GEM detectors

Systematic studies on the gain and the energy resolution have been carried out varying the voltage across the GEM foils for both single mask and double mask triple GEM detector prototypes. Variation of the gain and the energy resolution have also been measured varying either the drift voltage, transfer voltage and induction voltage keeping other voltages constant. The results of the systematic measurements has been presented.

physics.ins-det

Study of the characteristics of GEM detectors for the future FAIR experiment CBM

Characteristics of triple GEM detector have been studied systematically. The variation of the effective gain and energy resolution of GEM with variation of the applied voltage has been measured with Fe55 X-ray source for different gas mixtures and with different gas flow rates. Long-term test of the GEM has also been performed.

physics.ins-det

Development of a GEM based detector for the CBM Muon Chamber (MUCH)

The characteristics of triple GEM detectors have been studied systematically by using cosmic ray muons. The minimum ionizing particle (MIP) spectra has been taken for different GEM voltage setting. Efficiency of GEM detector has been measured for cosmic ray. At high rate operation of GEMs the value of the protection resistor influences the gain and the stability. This feature has been investigated varying both the rate and the value of the protection resistor. This measurement has been performed using both X-ray generator and Fe55 source. The ageing and long-term stability of GEM based detectors has been studied employing both X-ray generator and Fe55 source. The ageing study of one GEM module is performed by using a 8 keV Cu X-ray generator to verify the stability and integrity of the GEM detectors over a longer period of time. The accumulated charge on the detector is calculated from the rate of the X-ray and the average gain of the detector. The details of the measurement and results has been described in this article.

physics.ins-det

The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we describe in detail the design considerations for this detector for operation in the extreme multiplicity environment of central Pb--Pb collisions at LHC energy. The implementation of the resulting requirements into hardware (field cage, read-out chambers, electronics), infrastructure (gas and cooling system, laser-calibration system), and software led to many technical innovations which are described along with a presentation of all the major components of the detector, as currently realized. We also report on the performance achieved after completion of the first round of stand-alone calibration runs and demonstrate results close to those specified in the TPC Technical Design Report.

physics.ins-det