SearcharxivSearch

arXiv · 2503.15721

Minimal material, maximum coverage: Silicon Tracking System for high-occupancy conditions

Abstract

Silicon strip sensors have long been a reliable technology for particle detection. Here, we push the limits of silicon tracking detectors by targeting an unprecedentedly low material budget of 2%-7% $X_0$ in an 8-layer 4 m$^2$ detector designed for high-occupancy environments ($\leq$ 10 MHz/cm$^2$). To achieve this, we employ Double-Sided Double Metal (DSDM) silicon microstrip sensors, coupled with readout electronics capable of precise timing and energy measurements. These 320 $\mu$m thick sensors, featuring $2\times 1024$ channels with a 58 $\mu$m pitch, are connected via ultra-lightweight aluminium-polyimide microcables for signal transmission and integrated with a custom SMX readout ASIC, operating in free-streaming mode. This system enables the simultaneous measurement of time ($\Delta t \simeq 5$~ns) and charge deposition (0.1-100 fC), significantly enhancing the detector's capacity for high-precision track reconstruction in high-occupancy and harsh radiation field environments. The primary application of this technology is the Silicon Tracking System (STS) for the CBM experiment, with additional potential in projects like the J-PARC E16 experiment and future uses in medical physics, such as advanced imaging telescopes. In this contribution, we present the current status of CBM STS construction, with almost one-third of the modules produced and tested. We also discuss immediate applications and explore promising prospects in both scientific and medical fields.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M. Teklishyn, L. M. Collazo Sánchez, U. Frankenfeld, J. M. Heuser, O. Kshyvanskyi, J. Lehnert, D. A. Ramírez Zaldivar, D. Rodríguez Garcés, A. Rodríguez Rodríguez, C. J. Schmidt, P. Semeniuk, M. Shiroya, A. Sharma, A. Toia, O. Vasylyev. 2025-03-19. Minimal material, maximum coverage: Silicon Tracking System for high-occupancy conditions. https://arxiv.org/abs/2503.15721

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det