SearcharxivSearch

arXiv subjects

U. Kose

Publications and source records attributed to U. Kose.

At least 19 recordsLinked to original sources

A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator

This study presents the development and the characterization of novel white reflective filaments suitable for additive manufacturing of finely segmented plastic scintillators. The filament is based on polycarbonate (PC) and polymethyl methacrylate (PMMA) polymers loaded with titanium dioxide (TiO$_2$) and polytetrafluoroethylene (PTFE) to enhance reflectivity. A range of filament compositions and thicknesses was evaluated through optical reflection and transmittance measurements of reflective layers made with the Fused Deposition Modeling (FDM) technique. A 3D-segmented plastic scintillator prototype was made with fused injection modeling (FIM) and tested with cosmic rays to assess the light yield and the optical crosstalk. The results demonstrate the feasibility of producing compact and modular 3D-printed scintillator detectors with a performance analogous to standard plastic scintillator detectors. Owing to the improved optical properties of the new reflector filament, a lower light crosstalk and a higher light yield, compared to past works, is obtained.

physics.ins-det

A new diffuse reflector filament for additive manufacturing of 3D printing finely-segmented plastic scintillator

This study presents the development and characterization of a novel white reflective filament suitable for additive manufacturing of finely segmented plastic scintillators using 3D printing. The filament is based on polycarbonate (PC) and polymethyl methacrylate (PMMA) polymers loaded with titanium dioxide (TiO$_2$) and polytetrafluoroethylene (PTFE) to enhance reflectivity. A range of filament compositions and thicknesses was evaluated through optical reflection and transmittance measurements. Reflective layers were made by using the Fused Deposition Modeling (FDM) technique. A 3D-segmented plastic scintillator prototype was made with fused injection modeling (FIM) and tested with cosmic rays to assess the light yield and the optical crosstalk. The results demonstrate the feasibility of producing compact and modular 3D-printed scintillator detectors with a performance analogous to standard plastic scintillator detectors, with lower light crosstalk, thus higher light yield, compared to past works, owing to the improved optical properties of the reflector material.

physics.ins-det

Design and Implementation of the Cosmic Ray Tagger System for the ICARUS detector at FNAL

The ICARUS-T600 Liquid Argon Time Projection Chamber is operating at Fermilab at shallow depth and thus exposed to a high flux of cosmic rays that can fake neutrino interactions. A cosmic ray tagging (CRT) system ($\sim$1100 m$^2$), surrounding the cryostat with two layers of fiber embedded plastic scintillators, was developed to mitigate the cosmic ray induced background. Using nanosecond-level timing information, the CRT can distinguish incoming cosmic rays from outgoing particles from neutrino interactions in the TPC. In this paper an overview of the CRT system, its installation and commissioning at Fermilab, and its performance are discussed.

hep-ex

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector

The magnetised near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrinonucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm3 cubes. It will provide a 3D image of GeV neutrino interactions by combining tracking and stopping power measurements of final state particles with sub-nanosecond time resolution. The performance of SuperFGD is characterized by the precision of its response to charged particles as well as the systematic effects that might affect the physics measurements. Hence, a detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

hep-ex

A Hybrid 3D/2D Field Response Calculation for Liquid Argon Detectors with PCB Based Anode Plane

Liquid Argon Time Projection Chamber (LArTPC) technology is commonly utilized in neutrino detector designs. It enables detailed reconstruction of neutrino events with high spatial precision and low energy threshold. Its field response (FR) model describes the time-dependent electric currents induced in the anode-plane electrodes when ionization electrons drift nearby. An accurate and precise FR is a crucial input to LArTPC detector simulations and charge reconstruction. Established LArTPC designs have been based on parallel wire planes. It allows accurate and computationally economic two-dimensional (2D) FR models utilizing the translational symmetry along the direction of the wires. Recently, novel LArTPC designs utilize electrodes formed on printed circuit board (PCB) in the shape of strips with through holes. The translational symmetry is no longer a good approximation near the electrodes and a new FR calculation that employs regions with three dimensions (3D) has been developed. Extending the 2D models to 3D would be computationally expensive. Fortuitously, the nature of strips with through holes allows for a computationally economic approach based on the finite-difference method (FDM). In this paper, we present a new software package "pochoir" that calculates LArTPC field response for these new strip-based anode designs. This package combines 3D calculations in the volume near the electrodes with 2D far-field solutions to achieve fast and precise field response computation. We apply the resulting FR to simulate and reconstruct samples of cosmic-ray muons and $^{39}$Ar decays from a Vertical Drift (VD) detector prototype operated at CERN. We find the difference between real and simulated data within 5 %. Current state-of-the-art LArTPC software requires a 2D FR which we provide by averaging over one dimension and estimate that variations lost in this average are smaller than 7 %.

physics.ins-det

Updated constraints on sterile neutrino mixing in the OPERA experiment using a new $ν_e$ identification method

This paper describes a new $ν_e$ identification method specifically designed to improve the low-energy ($< 30\,\mathrm{GeV}$) $ν_e$ identification efficiency attained by enlarging the emulsion film scanning volume with the next generation emulsion readout system. A relative increase of 25-70% in the $ν_e$ low-energy region is expected, leading to improvements in the OPERA sensitivity to neutrino oscillations in the framework of the 3 + 1 model. The method is applied to a subset of data where the detection efficiency increase is expected to be more relevant, and one additional $ν_e$ candidate is found. The analysis combined with the $ν_τ$ appearance results improves the upper limit on $\sin^2 2θ_{μe}$ to 0.016 at 90% C.L. in the MiniBooNE allowed region $Δm^2_{41} \sim 0.3\,\mathrm{eV}^2$.

hep-ex

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

physics.ins-det

Additive manufacturing of inorganic scintillator-based particle detectors

Inorganic scintillators are widely used for scientific, industrial and medical applications. The development of 3D printing with inorganic scintillators would allow fast creation of detector prototypes for registration of ionizing radiation, such as alpha and beta, gamma particles in thin layers of active material and soft X-ray radiation. This article reports on the technical work and scientific achievements that aimed at developing a new inorganic scintillation filament to be used for the 3D printing of composite scintillator materials: study and definition of the scintillator composition; development of the methods for the inorganic scintillator filament production and further implementation in the available 3D printing technologies; study of impact of the different 3D printing modes on the material scintillation characteristics. Also, 3D printed scintillators can be used for creation of combined detectors for high-energy physics.

physics.ins-det

Additive manufacturing of fine-granularity optically-isolated plastic scintillator elements

Plastic scintillator detectors are used in high energy physics as well as for diagnostic imaging in medicine, beam monitoring on hadron therapy, muon tomography, dosimetry and many security applications. To combine particle tracking and calorimetry it is necessary to build detectors with three-dimensional granularity, i.e. small voxels of scintillator optically isolated from each other. Recently, the 3DET collaboration demonstrated the possibility to 3D print polystyrene-based scintillators with a light output performance close to that obtained with standard production methods. In this article, after providing a further characterization of the developed scintillators, we show the first matrix of plastic scintillator cubes optically separated by a white reflector material entirely 3D printed with fused deposition modeling. This is a major milestone towards the 3D printing of the first real particle detector. A discussion of the results as well as the next steps in the R&D is also provided.

physics.ins-det

Total Neutron Cross-section Measurement on CH with a Novel 3D-projection Scintillator Detector

In order to extract neutrino oscillation parameters, precision long-baseline neutrino oscillation experiments rely on detailed models of neutrino interactions with nuclei. These models constitute an important source of systematic uncertainty, partially because detectors to date have been blind to final state neutrons. Three-dimensional projection scintillator trackers comprise components of the near detectors of the next generation long-baseline neutrino experiments. Due to the good timing resolution and fine granularity, this technology is capable of measuring neutron kinetic energy in neutrino interactions on an event-by-event basis and will provide valuable data for refining neutrino interaction models and ways to reconstruct neutrino energy. Two prototypes have been exposed to the neutron beamline at Los Alamos National Laboratory (LANL) in both 2019 and 2020, with neutron energies between 0 and 800 MeV. In order to demonstrate the capability of neutron detection, the total neutron-scintillator cross section is measured and compared to external measurements. The measured total neutron cross section in scintillator between 98 and 688 MeV is 0.36 $\pm$ 0.05 barn.

physics.ins-det

Demonstrating a single-block 3D-segmented plastic-scintillator detector

Three-dimensional finely grained plastic scintillator detectors bring many advantages in particle detectors, allowing a massive active target which enables a high-precision tracking of interaction products, excellent calorimetry and a sub-nanosecond time resolution. Whilst such detectors can be scaled up to several-tonnes, as required by future neutrino experiments, a relatively long production time, where each single plastic-scintillator element is independently manufactured and machined, together with potential challenges in the assembly, complicates their realisation. In this manuscript we propose a novel design for 3D granular scintillator detectors where O($1~\text{cm}^3$) cubes are efficiently glued in a single block of scintillator after being produced via cast polymerization, which can enable rapid and cost-efficient detector construction. This work could become particularly relevant for the detectors of the next-generation long-baseline neutrino-oscillation experiments, such as DUNE, Hyper-Kamiokande and ESSnuB.

physics.ins-det

A measurement of the group velocity of scintillation light in liquid argon

The propagation velocity of scintillation light in liquid argon $v_{g}$ at $λ\sim 128$~nm wavelength, has been measured for the first time in a dedicated experimental setup at CERN.\\ The obtained result $\frac{1}{v_{g}} = 7.46 \pm 0.08$~ns/m , is then used to derive the value of the refractive index (n) and the Rayleigh scattering length ($\mathcal{L}$) for liquid argon in the VUV region. For $λ= 128$~nm we found $n= 1.358 \pm 0.003$ and $\mathcal{L}= 99.1 \pm 2.3$~cm. The measured values are of interest for a variety of experiments searching for rare events like neutrino and dark matter interactions. The derived quantities also represent key information for theoretical models describing the propagation of scintillation light in liquid argon.

physics.ins-det

A novel polystyrene-based scintillator production process involving additive manufacturing

Plastic scintillator detectors are widely used in particle physics thanks to the very good particle identification, tracking capabilities and time resolution. However, new experimental challenges and the need for enhanced performance require the construction of detector geometries that are complicated using the current production techniques. In this article we propose a new production technique based on additive manufacturing that aims to 3D print polystyrene-based scintillator. The production process and the results of the scintillation light output measurement of the 3D-printed scintillator are reported.

physics.ins-det

Design and implementation of the new scintillation light detection system of ICARUS T600

ICARUS T600 is the far detector of the Short Baseline Neutrino program at Fermilab(USA), which foresees three Liquid Argon Time Projection Chambers along the Booster Neutrino Beam line to search for LSND-like sterile neutrino signal. The T600 detector underwent a significant overhauling process at CERN, introducing new technological developments while maintaining the already achieved performances. The realization of a new liquid argon scintillation light detection system is a primary task of the detector overhaul. As the detector will be subject to a huge flux of cosmic rays, the light detection system should allow the 3D reconstruction of events contributing to the identification of neutrino interactions in the beam spill gate. The design and implementationof the new scintillation light detection system of ICARUS T600 is described.

physics.ins-det

First observation of a tau neutrino charged current interaction with charm production in the Opera experiment

An event topology with two secondary vertices compatible with the decay of short-lived particles was found in the analysis of neutrino interactions in the Opera target. The observed topology is compatible with tau neutrino charged current (CC) interactions with charm production and neutrino neutral current (NC) interactions with $c\overline{c}$ pair production. However, other processes can mimic this topology. A dedicated analysis was implemented to identify the underlying process. A Monte Carlo simulation was developed and complementary procedures were introduced in the kinematic reconstruction. A multivariate analysis technique was used to achieve an optimal separation of signal from background. Most likely, this event is a $ν_τ$ CC interaction with charm production, the tau and charm particle decaying into 1 prong and 2 prongs, respectively. The significance of this observation is evaluated.

hep-ex

Construction of precision wire readout planes for the Short-Baseline Near Detector (SBND)

The Short-Baseline Near Detector time projection chamber is unique in the design of its charge readout planes. These anode plane assemblies (APAs) have been fabricated and assembled to meet strict accuracy and precision requirements: wire spacing of 3 mm +/- 0.5 mm and wire tension of 7 N +/- 1 N across 3,964 wires per APA, and flatness within 0.5 mm over the 4 m +/- 2.5 m extent of each APA. This paper describes the design, manufacture and assembly of these key detector components, with a focus on the quality assurance at each stage.

physics.ins-det

Measurement of Liquid Argon Scintillation Light Properties by means of an Alpha Source placed inside the CERN 10-PMT LAr Detection System

A particle detection system that exploits the scintillation light produced by ionizing particles in liquid argon (LAr) has been assembled at CERN. The system is based on 10 large-area photomultiplier tubes (PMT) immersed in a 1500-liter dewar filled with liquid argon and equipped with an extendible feed-through and mechanical support for an alpha source (241Am). The position of the source can be changed with respect to the PMT plane in vertical and horizontal directions. Arrays of silicon photomultiplier (SiPM) photodetectors, integrated in the source support, are used for the data acquisition trigger and to define the t0 of the light generation. PMT and SiPM signals can be recorded at different distances and different positions allowing the measurement of some of the LAr scintillation light properties. The system was studied and characterized in detail, and physics results on LAr scintillation properties are expected soon.

physics.ins-det

Final results on neutrino oscillation parameters from the OPERA experiment in the CNGS beam

The OPERA experiment has conclusively observed the appearance of tau neutrinos in the muon neutrino CNGS beam. Exploiting the OPERA detector capabilities, it was possible to isolate high purity samples of $ν_{e}$, $ν_μ$ and $ν_τ$ charged current weak neutrino interactions, as well as neutral current weak interactions. In this Letter, the full dataset is used for the first time to test the three-flavor neutrino oscillation model and to derive constraints on the existence of a light sterile neutrino within the framework of the $3+1$ neutrino model. For the first time, tau and electron neutrino appearance channels are jointly used to test the sterile neutrino hypothesis. A significant fraction of the sterile neutrino parameter space allowed by LSND and MiniBooNE experiments is excluded at 90% C.L. In particular, the best-fit values obtained by MiniBooNE combining neutrino and antineutrino data are excluded at 3.3 $σ$ significance.

hep-ex