Search for Double Beta Decays of $^{134}$Xe with EXO-200 Phase II

EXO-200 was a leading double beta decay experiment consisting of a single-phase, enriched liquid xenon time projection chamber filled with an admixture of 80.672% $^{136}$Xe and 19.098% $^{134}$Xe. The detector operated at WIPP between 2010 and 2018 and was designed to search for double beta decay of $^{136}$Xe. Data was acquired in two phases separated by a period of detector upgrades. We report on the search for $0\nu\beta\beta$ and $2\nu\beta\beta$ decay of $^{134}$Xe with Phase II EXO-200 data, with median 90% C.L. exclusion sensitivity $T_{1/2}^{0\nu} \geq 3.7\times 10^{23}$ yr and $T_{1/2}^{2\nu} \geq 2.6 \times 10^{21}$ yr, respectively. No statistically significant signal is observed for either decay mode. We set a world-leading lower limit on the half-life of the neutrinoless decay mode of $^{134}$Xe of $T_{1/2}^{0\nu} \geq 8.7\times10^{23}$ (90% C.L.) and the second strongest constraint on the two-neutrino decay of $T_{1/2}^{2\nu} \geq 2.9\times10^{21}$ (90% C.L.), a 3-fold improvement over the EXO-200 Phase I measurement. New constraints are also set for the $2\nu\beta\beta$ and $0\nu\beta\beta$ decays of $^{134}$Xe to the lowest excited state of $^{134}$Ba.

nucl-ex

Absorption of Fermionic Dark Matter in the PICO-60 C$_{3}$F$_{8}$ Bubble Chamber

Fermionic dark matter absorption on nuclear targets via neutral current interactions is explored using a non-relativistic effective field theory framework. An analysis of data from the PICO-60 C$_{3}$F$_{8}$ bubble chamber sets leading constraints on spin-independent absorption for dark matter masses below 23 MeV/$\textit{c}^2$ and establishes the first limits on spin-dependent absorptive interactions. These results demonstrate the sensitivity of bubble chambers to low-mass dark matter and underscore the importance of absorption searches in expanding the parameter space of direct detection experiments.

hep-ex

Search for Two-neutrino Double-Beta Decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ with the Complete EXO-200 Dataset

A new search for two-neutrino double-beta ($2νββ$) decay of $^{136}\rm Xe$ to the $0^+_1$ excited state of $^{136}\rm Ba$ is performed with the full EXO-200 dataset. A deep learning-based convolutional neural network is used to discriminate signal from background events. Signal detection efficiency is increased relative to previous searches by EXO-200 by more than a factor of two. With the addition of the Phase II dataset taken with an upgraded detector, the median 90$\%$ confidence level half-life sensitivity of $2νββ$ decay to the $0^+_1$ state of $^{136}\rm Ba$ is $2.9 \times 10^{24}~\rm yr$ using a total $^{136}\rm Xe$ exposure of $234.1~\rm kg~yr$. No statistically significant evidence for $2νββ$ decay to the $0^+_1$ state is observed, leading to a lower limit of $T^{2ν}_{1/2}(0^+ \rightarrow 0^+_1) > 1.4\times10^{24}~\rm yr$ at 90$\%$ confidence level, improved by 70$\%$ relative to the current world's best constraint.

hep-ex

Search for MeV Electron Recoils from Dark Matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron recoil background rate of $6.8 \times 10^{-4}\, \mathrm{cts}\,\mathrm{kg}^{-1}\mathrm{yr}^{-1}\mathrm{keV}^{-1}$ above $4\,\mathrm{MeV}$ and find no statistically significant excess over our background projection. Using a total ${}^{136}\mathrm{Xe}$ exposure of $234.1\,\mathrm{kg}\,\mathrm{yr}$ we exclude new parameter space for the charged-current absorption cross-section for dark matter masses between $m_χ= 2.6\,\mathrm{MeV} - 11.6\,\mathrm{MeV}$ with a minimum of $6\times 10^{-51}\,\mathrm{cm}^2$ at $8.3\,\mathrm{MeV}$ at the $90\%$ confidence level.

hep-ex

Search for inelastic dark matter-nucleus scattering with the PICO-60 CF$_{3}$I and C$_{3}$F$_{8}$ bubble chambers

PICO bubble chambers have exceptional sensitivity to inelastic dark matter-nucleus interactions due to a combination of their extended nuclear recoil energy detection window from a few keV to $O$(100 keV) or more and the use of iodine as a heavy target. Inelastic dark matter-nucleus scattering is interesting for studying the properties of dark matter, where many theoretical scenarios have been developed. This study reports the results of a search for dark matter inelastic scattering with the PICO-60 bubble chambers. The analysis reported here comprises physics runs from PICO-60 bubble chambers using CF$_{3}$I and C$_{3}$F$_{8}$. The CF$_{3}$I run consisted of 36.8 kg of CF$_{3}$I reaching an exposure of 3415 kg-day operating at thermodynamic thresholds between 7 and 20 keV. The C$_{3}$F$_{8}$ runs consisted of 52 kg of C$_{3}$F$_{8}$ reaching exposures of 1404 kg-day and 1167 kg-day running at thermodynamic thresholds of 2.45 keV and 3.29 keV, respectively. The analysis disfavors various scenarios, in a wide region of parameter space, that provide a feasible explanation of the signal observed by DAMA, assuming an inelastic interaction, considering that the PICO CF$_{3}$I bubble chamber used iodine as the target material.

astro-ph.CO

Status of the X17 search in Montreal

At the Montreal Tandem accelerator, an experiment is being set up to measure internal pair creation from the decay of nuclear excited states using a multiwire proportional chamber and scintillator bars surrounding it from the DAPHNE experiment. The acceptance covers a solid angle of nearly 4$π$. Preamplifiers and the data acquisition hardware have been designed and tested. The water-cooled $^7$LiF target, mounted on an Al foil is in a thin carbon fiber section of the beamline. The experiment will focus at first on a measurement of the internal pair creation from the 18.15 MeV state of $^8$Be. Assuming the ATOMKI evaluation of the electron-pair production rate from X17, a Geant4 simulation predicts observation of a clear signal after about two weeks of data taking with a 2 $μ$A proton beam. The IPC measurement could eventually be extended to the giant dipole resonance of $^8$Be, as well as to other nuclei, in particular to $^{10}$B.

physics.ins-det

Determining the bubble nucleation efficiency of low-energy nuclear recoils in superheated C$_3$F$_8$ dark matter detectors

The bubble nucleation efficiency of low-energy nuclear recoils in superheated liquids plays a crucial role in interpreting results from direct searches for weakly interacting massive particle (WIMP) dark matter. The PICO Collaboration presents the results of the efficiencies for bubble nucleation from carbon and fluorine recoils in superheated C$_3$F$_8$ from calibration data taken with 5 distinct neutron spectra at various thermodynamic thresholds ranging from 2.1 keV to 3.9 keV. Instead of assuming any particular functional forms for the nuclear recoil efficiency, a generalized piecewise linear model is proposed with systematic errors included as nuisance parameters to minimize model-introduced uncertainties. A Markov-Chain Monte-Carlo (MCMC) routine is applied to sample the nuclear recoil efficiency for fluorine and carbon at 2.45 keV and 3.29 keV thermodynamic thresholds simultaneously. The nucleation efficiency for fluorine was found to be $\geq 50\, \%$ for nuclear recoils of 3.3 keV (3.7 keV) at a thermodynamic Seitz threshold of 2.45 keV (3.29 keV), and for carbon the efficiency was found to be $\geq 50\, \%$ for recoils of 10.6 keV (11.1 keV) at a threshold of 2.45 keV (3.29 keV). Simulated data sets are used to calculate a p-value for the fit, confirming that the model used is compatible with the data. The fit paradigm is also assessed for potential systematic biases, which although small, are corrected for. Additional steps are performed to calculate the expected interaction rates of WIMPs in the PICO-60 detector, a requirement for calculating WIMP exclusion limits.

physics.ins-det

Results on photon-mediated dark matter-nucleus interactions from the PICO-60 C$_{3}$F$_{8}$ bubble chamber

Many compelling models predict dark matter coupling to the electromagnetic current through higher multipole interactions, while remaining electrically neutral. Different multipole couplings have been studied, among them anapole moment, electric and magnetic dipole moments, and millicharge. This study sets limits on the couplings for these photon-mediated interactions using non-relativistic contact operators in an effective field theory framework. Using data from the PICO-60 bubble chamber leading limits for dark matter masses between 2.7 GeV/c$^2$ and 24 GeV/c$^2$ are reported for the coupling of these photon-mediated dark matter-nucleus interactions. The detector was filled with 52 kg of C$_3$F$_8$ operating at thermodynamic thresholds of 2.45 keV and 3.29 keV, reaching exposures of 1404 kg-day and 1167 kg-day, respectively.

astro-ph.CO

Search for Majoron-emitting modes of $^{136}$Xe double beta decay with the complete EXO-200 dataset

A search for Majoron-emitting modes of the neutrinoless double-beta decay of $^{136}$Xe is performed with the full EXO-200 dataset. This dataset consists of a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr, and includes data with detector upgrades that have improved the energy threshold relative to previous searches. A lower limit of T$_{1/2}^{\rm{^{136}Xe}}>$4.3$\cdot$10$^{24}$ yr at 90\% C.L. on the half-life of the spectral index $n=1$ Majoron decay was obtained, a factor of 3.6 more stringent than the previous limit from EXO-200, corresponding to a constraint on the Majoron-neutrino coupling constant of $|\langle g_{ee}^{M}\rangle|$$<(0.4$-$0.9)\cdot10^{-5}$. The lower threshold and the additional data taken resulted in a factor 8.4 improvement for the $n=7$ mode compared to the previous EXO search. This search provides the most stringent limits to-date on the Majoron-emitting decays of $^{136}$Xe with spectral indices $n=1,2,3,$ and 7.

hep-ex

Data-Driven Modeling of Electron Recoil Nucleation in PICO C$_3$F$_8$ Bubble Chambers

The primary advantage of moderately superheated bubble chamber detectors is their simultaneous sensitivity to nuclear recoils from WIMP dark matter and insensitivity to electron recoil backgrounds. A comprehensive analysis of PICO gamma calibration data demonstrates for the first time that electron recoils in C$_3$F$_8$ scale in accordance with a new nucleation mechanism, rather than one driven by a hot-spike as previously supposed. Using this semi-empirical model, bubble chamber nucleation thresholds may be tuned to be sensitive to lower energy nuclear recoils while maintaining excellent electron recoil rejection. The PICO-40L detector will exploit this model to achieve thermodynamic thresholds as low as 2.8 keV while being dominated by single-scatter events from coherent elastic neutrino-nucleus scattering of solar neutrinos. In one year of operation, PICO-40L can improve existing leading limits from PICO on spin-dependent WIMP-proton coupling by nearly an order of magnitude for WIMP masses greater than 3 GeV c$^{-2}$ and will have the ability to surpass all existing non-xenon bounds on spin-independent WIMP-nucleon coupling for WIMP masses from 3 to 40 GeV c$^{-2}$.

physics.ins-det

Measurement of the scintillation and ionization response of liquid xenon at MeV energies in the EXO-200 experiment

Liquid xenon (LXe) is employed in a number of current and future detectors for rare event searches. We use the EXO-200 experimental data to measure the absolute scintillation and ionization yields generated by $γ$ interactions from $^{228}$Th (2615~keV), $^{226}$Ra (1764~keV) and $^{60}$Co (1332~keV and 1173~keV) calibration sources, over a range of electric fields. The $W$-value that defines the recombination-independent energy scale is measured to be $11.5~\pm~0.5$~(syst.)~$\pm~0.1$~(stat.) eV. These data are also used to measure the recombination fluctuations in the number of electrons and photons produced by the calibration sources at the MeV-scale, which deviate from extrapolations of lower-energy data. Additionally, a semi-empirical model for the energy resolution of the detector is developed, which is used to constrain the recombination efficiency, i.e., the fraction of recombined electrons that result in the emission of a detectable photon. Detailed measurements of the absolute charge and light yields for MeV-scale electron recoils are important for predicting the performance of future neutrinoless double beta decay detectors.

physics.ins-det

Measurement of the Spectral Shape of the beta-decay of 137Xe to the Ground State of 137Cs in EXO-200 and Comparison with Theory

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden non-unique $β$-decay transition $^{137}\textrm{Xe}(7/2^-)\to\,^{137}\textrm{Cs}(7/2^+)$. The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultra-low background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal-to-background ratio of more than 99-to-1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden non-unique $β$-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

nucl-ex

Search for Neutrinoless Double-Beta Decay with the Complete EXO-200 Dataset

A search for neutrinoless double-beta decay ($0νββ$) in $^{136}$Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between $0νββ$ and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4$\pm$3.0% and the energy resolution of the detector at the Q-value of $^{136}$Xe $0νββ$ has been improved from $σ/E=1.23\%$ to $1.15\pm0.02\%$ with the upgraded detector. Accounting for the new data, the median 90% confidence level $0νββ$ half-life sensitivity for this analysis is $5.0 \cdot 10^{25}$ yr with a total $^{136}$Xe exposure of 234.1 kg$\cdot$yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $3.5\cdot10^{25}$ yr at the 90% confidence level.

hep-ex

Dark Matter Search Results from the Complete Exposure of the PICO-60 C$_3$F$_8$ Bubble Chamber

Final results are reported from operation of the PICO-60 C$_3$F$_8$ dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. The chamber was operated at thermodynamic thresholds as low as 1.2 keV without loss of stability. A new blind 1404-kg-day exposure at 2.45 keV threshold was acquired with approximately the same expected total background rate as the previous 1167-kg-day exposure at 3.3 keV. This increased exposure is enabled in part by a new optical tracking analysis to better identify events near detector walls, permitting a larger fiducial volume. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 2.5 $\times$ 10$^{-41}$ cm$^2$ for a 25 GeV WIMP, and improve on previous PICO results for 3-5 GeV WIMPs by an order of magnitude.

astro-ph.CO

Developing a Bubble Chamber Particle Discriminator Using Semi-Supervised Learning

The identification of non-signal events is a major hurdle to overcome for bubble chamber dark matter experiments such as PICO-60. The current practice of manually developing a discriminator function to eliminate background events is difficult when available calibration data is frequently impure and present only in small quantities. In this study, several different discriminator input/preprocessing formats and neural network architectures are applied to the task. First, they are optimized in a supervised learning context. Next, two novel semi-supervised learning algorithms are trained, and found to replicate the Acoustic Parameter (AP) discriminator previously used in PICO-60 with a mean of 97% accuracy.

physics.comp-ph

Deep Neural Networks for Energy and Position Reconstruction in EXO-200

We apply deep neural networks (DNN) to data from the EXO-200 experiment. In the studied cases, the DNN is able to reconstruct the relevant parameters - total energy and position - directly from raw digitized waveforms, with minimal exceptions. For the first time, the developed algorithms are evaluated on real detector calibration data. The accuracy of reconstruction either reaches or exceeds what was achieved by the conventional approaches developed by EXO-200 over the course of the experiment. Most existing DNN approaches to event reconstruction and classification in particle physics are trained on Monte Carlo simulated events. Such algorithms are inherently limited by the accuracy of the simulation. We describe a unique approach that, in an experiment such as EXO-200, allows to successfully perform certain reconstruction and analysis tasks by training the network on waveforms from experimental data, either reducing or eliminating the reliance on the Monte Carlo.

physics.ins-det

Search for nucleon decays with EXO-200

A search for instability of nucleons bound in $^{136}$Xe nuclei is reported with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most stringent to date, exceeding the prior decay limits by a factor of 9 and 7, respectively.

hep-ex

Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector

Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.

hep-ex