Searcharxiv⌕ Search

arXiv subjects

U. Wichoski

Publications and source records attributed to U. Wichoski.

At least 37 records · Page 2Linked to original sources

Search for Neutrinoless Double-Beta Decay with the Upgraded EXO-200 Detector

Results from a search for neutrinoless double-beta decay $0νββ$ of $^{136}$Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to $σ/E$=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between $0νββ$ and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level $0νββ$ half-life sensitivity after combining with the full data set acquired before the upgrade has increased 2-fold to $3.7 \times 10^{25}$ yr. No statistically significant evidence for $0νββ$ is observed, leading to a lower limit on the $0νββ$ half-life of $1.8\times10^{25}$ yr at the 90% confidence level.

hep-ex↗

Searches for Double Beta Decay of $^{134}$Xe with EXO-200

Searches for double beta decay of $^{134}$Xe were performed with EXO-200, a single-phase liquid xenon detector designed to search for neutrinoless double beta decay of $^{136}$Xe. Using an exposure of $29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of $\text{T}_{1/2}^{2νβ\!β}>8.7\cdot10^{20}\text{ yr}$ and $\text{T}_{1/2}^{0νβ\!β}>1.1\cdot10^{23}\text{ yr}$ at 90% confidence level were derived, with corresponding half-life sensitivities of $1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits exceed those in the literature for $^{134}$Xe, improving by factors of nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes, respectively.

hep-ex↗

Dark Matter Search Results from the PICO-60 C$_3$F$_8$ Bubble Chamber

New results are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 52 kg of C$_3$F$_8$ located in the SNOLAB underground laboratory. As in previous PICO bubble chambers, PICO-60 C$_3$F$_8$ exhibits excellent electron recoil and alpha decay rejection, and the observed multiple-scattering neutron rate indicates a single-scatter neutron background of less than 1 event per month. A blind analysis of an efficiency-corrected 1167-kg-day exposure at a 3.3-keV thermodynamic threshold reveals no single-scattering nuclear recoil candidates, consistent with the predicted background. These results set the most stringent direct-detection constraint to date on the WIMP-proton spin-dependent cross section at 3.4 $\times$ 10$^{-41}$ cm$^2$ for a 30-GeV$\thinspace$c$^{-2}$ WIMP, more than one order of magnitude improvement from previous PICO results.

astro-ph.CO↗

Measurements of the ion fraction and mobility of alpha and beta decay products in liquid xenon using EXO-200

Alpha decays in the EXO-200 detector are used to measure the fraction of charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$ of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral. The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of $^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer drift times. Initially the ions have a mobility of $0.390 \pm 0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time constants associated with the change in mobility during drift of the $^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron lifetime in the LXe.

nucl-ex↗

Trace radioactive impurities in final construction materials for EXO-200

We report results from a systematic measurement campaign conducted to identify low radioactivity materials for the construction of the EXO-200 double beta decay experiment. Partial results from this campaign have already been reported in a 2008 paper by the EXO collaboration. Here we release the remaining data, collected since 2007, to the public. The data reported were obtained using a variety of analytic techniques. The measurement sensitivities are among the best in the field. Construction of the EXO-200 detector has been concluded, and Phase-I data was taken from 2011 to 2014. The detector's extremely low background implicitly verifies the measurements and the analysis assumptions made during construction and reported in this paper.

physics.ins-det↗

Final Results of the PICASSO Dark Matter Search Experiment

The PICASSO dark matter search experiment operated an array of 32 superheated droplet detectors containing 3.0 kg of C$_{4}$F$_{10}$ and collected an exposure of 231.4 kgd at SNOLAB between March 2012 and January 2014. We report on the final results of this experiment which includes for the first time the complete data set and improved analysis techniques including \mbox{acoustic} localization to allow fiducialization and removal of higher activity regions within the detectors. No signal consistent with dark matter was observed. We set limits for spin-dependent interactions on protons of $σ_p^{SD}$~=~1.32~$\times$~10$^{-2}$~pb (90\%~C.L.) at a WIMP mass of 20 GeV/c$^{2}$. In the spin-independent sector we exclude cross sections larger than $σ_p^{SI}$~=~4.86~$\times$~10$^{-5 }$~pb~(90\% C.L.) in the region around 7 GeV/c$^{2}$. The pioneering efforts of the PICASSO experiment have paved the way forward for a next generation detector incorporating much of this technology and experience into larger mass bubble chambers.

hep-ex↗

An apparatus to manipulate and identify individual Ba ions from bulk liquid Xe

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight (TOF) mass spectroscopy for positive identification of the barium decay product.

physics.ins-det↗

An Optimal Energy Estimator to Reduce Correlated Noise for the EXO-200 Light Readout

The energy resolution of the EXO-200 detector is limited by electronics noise in the measurement of the scintillation response. Here we present a new technique to extract optimal scintillation energy measurements for signals split across multiple channels in the presence of correlated noise. The implementation of these techniques improves the energy resolution of the detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm 0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.

physics.ins-det↗

Search for $2νββ$ decay of $^{136}$Xe to the 0$_1^+$ excited state of $^{136}$Ba with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba. We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe to the first $0^+$ excited state, $0^+_1$, of $^{136}$Ba based on a 100 kg$\cdot$yr exposure of $^{136}$Xe. Using a specialized analysis employing a machine learning algorithm, we obtain a 90% CL half-life sensitivity of $1.7 \times 10^{24}$ yr. We find no statistically significant evidence for the $2νββ$ decay to the excited state resulting in a lower limit of $T^{2ν}_{1/2}$ ($0^+ \rightarrow 0^+_1$) $> 6.9 \times 10^{23}$ yr at 90% CL. This observed limit is consistent with the estimated half-life of $2.5\times10^{25}$ yr.

nucl-ex↗

Measurement of the Drift Velocity and Transverse Diffusion of Electrons in Liquid Xenon with the EXO-200 Detector

The EXO-200 Collaboration is searching for neutrinoless double beta decay using a liquid xenon (LXe) time projection chamber. This measurement relies on modeling the transport of charge deposits produced by interactions in the LXe to allow discrimination between signal and background events. Here we present measurements of the transverse diffusion constant and drift velocity of electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At the operating field of 380~V/cm EXO-200 measures a drift velocity of 1.705$_{-0.010}^{+0.014}$~mm/$μ$s and a transverse diffusion coefficient of 55$\pm$4~cm$^2$/s.

physics.ins-det↗

Cosmogenic Backgrounds to 0νββ in EXO-200

As neutrinoless double-beta decay experiments become more sensitive and intrinsic radioactivity in detector materials is reduced, previously minor contributions to the background must be understood and eliminated. With this in mind, cosmogenic backgrounds have been studied with the EXO-200 experiment. Using the EXO-200 TPC, the muon flux (through a flat horizontal surface) underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be Φ = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys) $\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations of muon-induced backgrounds identified several potential cosmogenic radionuclides, though only 137Xe is a significant background for the 136Xe 0νββ search with EXO-200. Muon-induced neutron backgrounds were measured using γ-rays from neutron capture on the detector materials. This provided a measurement of 137Xe yield, and a test of the accuracy of the neutron production and transport simulations. The independently measured rates of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4 and FLUKA simulations were performed to estimate neutron capture rates, and these estimates agreed to within ~40% or better with measurements. The ability to identify 136Xe(n,γ) events will allow for rejection of 137Xe backgrounds in future 0νββ analyses.

nucl-ex↗

First Search for Lorentz and CPT Violation in Double Beta Decay with EXO-200

A search for Lorentz- and CPT-violating signals in the double beta decay spectrum of $^{136}$Xe has been performed using an exposure of 100 kg$\cdot$yr with the EXO-200 detector. No significant evidence of the spectral modification due to isotropic Lorentz-violation was found, and a two-sided limit of $-2.65 \times 10^{-5 } \; \textrm{GeV} < \mathring{a}^{(3)}_{\text{of}} < 7.60 \times 10^{-6} \; \textrm{GeV}$ (90% C.L.) is placed on the relevant coefficient within the Standard-Model Extension (SME). This is the first experimental study of the effect of the SME-defined oscillation-free and momentum-independent neutrino coupling operator on the double beta decay process.

nucl-ex↗

Improved dark matter search results from PICO-2L Run 2

New data are reported from a second run of the 2-liter PICO-2L C$_3$F$_8$ bubble chamber with a total exposure of 129$\,$kg-days at a thermodynamic threshold energy of 3.3$\,$keV. These data show that measures taken to control particulate contamination in the superheated fluid resulted in the absence of the anomalous background events observed in the first run of this bubble chamber. One single nuclear-recoil event was observed in the data, consistent both with the predicted background rate from neutrons and with the observed rate of unambiguous multiple-bubble neutron scattering events. The chamber exhibits the same excellent electron-recoil and alpha decay rejection as was previously reported. These data provide the most stringent direct detection constraints on weakly interacting massive particle (WIMP)-proton spin-dependent scattering to date for WIMP masses $<$ 50$\,$GeV/c$^2$.

astro-ph.CO↗

Dark Matter Search Results from the PICO-60 CF$_3$I Bubble Chamber

New data are reported from the operation of the PICO-60 dark matter detector, a bubble chamber filled with 36.8 kg of CF$_3$I and located in the SNOLAB underground laboratory. PICO-60 is the largest bubble chamber to search for dark matter to date. With an analyzed exposure of 92.8 livedays, PICO-60 exhibits the same excellent background rejection observed in smaller bubble chambers. Alpha decays in PICO-60 exhibit frequency-dependent acoustic calorimetry, similar but not identical to that reported recently in a C$_3$F$_8$ bubble chamber. PICO-60 also observes a large population of unknown background events, exhibiting acoustic, spatial, and timing behaviors inconsistent with those expected from a dark matter signal. These behaviors allow for analysis cuts to remove all background events while retaining $48.2\%$ of the exposure. Stringent limits on weakly interacting massive particles interacting via spin-dependent proton and spin-independent processes are set, and most interpretations of the DAMA/LIBRA modulation signal as dark matter interacting with iodine nuclei are ruled out.

hep-ex↗

Investigation of radioactivity-induced backgrounds in EXO-200

The search for neutrinoless double-beta decay (0νββ) requires extremely low background and a good understanding of their sources and their influence on the rate in the region of parameter space relevant to the 0νββ signal. We report on studies of various β- and γ-backgrounds in the liquid- xenon-based EXO-200 0νββ experiment. With this work we try to better understand the location and strength of specific background sources and compare the conclusions to radioassay results taken before and during detector construction. Finally, we discuss the implications of these studies for EXO-200 as well as for the next-generation, tonne-scale nEXO detector.

physics.ins-det↗

Dark Matter Search Results from the PICO-2L C$_3$F$_8$ Bubble Chamber

New data are reported from the operation of a 2-liter C$_3$F$_8$ bubble chamber in the 2100 meter deep SNOLAB underground laboratory, with a total exposure of 211.5 kg-days at four different recoil energy thresholds ranging from 3.2 keV to 8.1 keV. These data show that C3F8 provides excellent electron recoil and alpha rejection capabilities at very low thresholds, including the first observation of a dependence of acoustic signal on alpha energy. Twelve single nuclear recoil event candidates were observed during the run. The candidate events exhibit timing characteristics that are not consistent with the hypothesis of a uniform time distribution, and no evidence for a dark matter signal is claimed. These data provide the most sensitive direct detection constraints on WIMP-proton spin-dependent scattering to date, with significant sensitivity at low WIMP masses for spin-independent WIMP-nucleon scattering.

astro-ph.CO↗

Search for Majoron-emitting modes of double-beta decay of $^{136}$Xe with EXO-200

EXO-200 is a single phase liquid xenon detector designed to search for neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe. A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the half-life of the spectral index = 1 Majoron decay was obtained, corresponding to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee} >|<$ (0.8-1.7)$\cdot$10$^{-5}$.

hep-ex↗

Spectroscopy of Ba and Ba$^+$ deposits in solid xenon for barium tagging in nEXO

Progress on a method of barium tagging for the nEXO double beta decay experiment is reported. Absorption and emission spectra for deposits of barium atoms and ions in solid xenon matrices are presented. Excitation spectra for prominent emission lines, temperature dependence and bleaching of the fluorescence reveal the existence of different matrix sites. A regular series of sharp lines observed in Ba$^+$ deposits is identified with some type of barium hydride molecule. Lower limits for the fluorescence quantum efficiency of the principal Ba emission transition are reported. Under current conditions, an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba atoms in solid xenon are discussed.

physics.atom-ph↗