Experiment BEST-2 with 58Co neutrino source

The article describes a new experiment with an artificial neutrino source 58Co on a gallium target GGNT (SAGE). The goal of the experiment is to study the gallium anomaly. The experiment makes it possible to find the parameters of oscillation transitions of electron neutrinos to sterile states in a wide range of parameters. Including the parameter Δm2, the experimental determination of which usually causes significant difficulties. An important feature of the experiment is the possibility of identifying the dependence of the gallium anomaly on the neutrino energy.

hep-ex

The Gallium Neutrino Absorption Cross Section and its Uncertainty

In the recent Baksan Experiment on Sterile Transitions (BEST), a suppressed rate of neutrino absorption on a gallium target was observed, consistent with earlier results from neutrino source calibrations of the SAGE and GALLEX/GNO solar neutrino experiments. The BEST collaboration, utilizing a 3.4 MCi 51Cr neutrino source, found observed-to-expected counting rates at two very short baselines of R=0.791 plus/minus 0.05 and 0.766 plus/minus 0.05, respectively. Among recent neutrino experiments, BEST is notable for the simplicity of both its neutrino spectrum, line neutrinos from an electron-capture source whose intensity can be measured to a estimated precision of 0.23%, and its absorption cross section, where the precisely known rate of electron capture to the gallium ground state, 71Ge(e,nue)71Ga(g.s.), establishes a minimum value. However, the absorption cross section uncertainty is a common systematic in the BEST, SAGE, and GALLEX/GNO neutrino source experiments. Here we update that cross section, considering a variety of electroweak corrections and the role of transitions to excited states, to establish both a central value and reasonable uncertainty, thereby enabling a more accurate assessment of the statistical significance of the gallium anomalies. Results are given for 51Cr and 37Ar sources. The revised neutrino capture rates are used in a re-evaluation of the BEST and gallium anomalies.

nucl-th

Production of the artificial 51Cr neutrino source in the BEST project

The production of the artificial 51Cr neutrino source with activity > 3 MCi for the experiment BEST is presented. This procedure consisted of making a 50Cr target and irradiating it with thermal neutrons in a nuclear reactor SM-3. The production of a target in the form of disks with a thickness of 4 mm and a diameter of 84 and 88 mm included enrichment (to 96.5% in 50Cr) of natural chromium in the form of oxyfluoride by gas centrifugation, electrolytic reduction and refining of metallic chromium, as well as the formation of chromium disks by spark plasma sintering. Simulations of various source geometries, neutron flux and nuclear transmutation were carried out to validate the design of the source, the irradiation device and the transport container, the required chemical purity of the target and the irradiation schedule in the reactor. The calculated activity of the source after 75 effective days of irradiation was 3.55 MCi. The activity of the source was measured by the calorimetric method and amounted to 3.41 MCi at the time of its delivery to the Baksan Neutrino Observatory. This is the most intense chemically pure neutrino source ever produced.

physics.ins-det

A Search for Electron Neutrino Transitions to Sterile States in the BEST Experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the $^{71}$Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi $^{51}$Cr neutrino source 10 times for a total of 20 independent $^{71}$Ge extractions from the two Ga targets. The $^{71}$Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with $^{71}$Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured $^{71}$Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the $4 σ$ deviations from unity consistent with the previously reported gallium anomaly. If interpreted in the context of neutrino oscillations, the deficits give best fit oscillation parameters of $Δm^2=3.3^{+\infty}_{-2.3}$ eV$^2$ and sin$^2 2θ=0.42^{+0.15}_{-0.17}$, consistent with $ν_e \rightarrow ν_s$ oscillations governed by a surprisingly large mixing angle.

nucl-ex

Results from the Baksan Experiment on Sterile Transitions (BEST)

The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $ν_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $ν_e$ and sterile neutrino ($ν_s$) states. A 3.414-MCi \nuc{51}{Cr} $ν_e$ source was placed at the center of two nested Ga volumes and measurements were made of the production of \nuc{71}{Ge} through the charged current reaction, \nuc{71}{Ga}($ν_e$,e$^-$)\nuc{71}{Ge}, at two average distances. The measured production rates for the inner and the outer targets respectively are ($54.9^{+2.5}_{-2.4}(\mbox{stat})\pm1.4 (\mbox{syst})$) and ($55.6^{+2.7}_{-2.6}(\mbox{stat})\pm1.4 (\mbox{syst})$) atoms of \nuc{71}{Ge}/d. The ratio ($R$) of the measured rate of \nuc{71}{Ge} production at each distance to the expected rate from the known cross section and experimental efficiencies are $R_{in}=0.79\pm0.05$ and $R_{out}= 0.77\pm0.05$. The ratio of the outer to the inner result is 0.97$\pm$0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20-24\% lower than expected, thus reaffirming the anomaly. These results are consistent with $ν_e \rightarrow ν_s$ oscillations with a relatively large $Δm^2$ ($>$0.5 eV$^2$) and mixing sin$^2 2θ$ ($\approx$0.4).

nucl-ex

Measurement of neutrino source activity in the experiment BEST by calorimetric method

Experiments to study non-standard properties of neutrinos using high-intensity artificial neutrino sources require high accuracy in determining their activity. A calorimetric system to determine the activity of a 51Cr neutrino source in the experiment BEST with an accuracy better than 1% was created. The design of the calorimetric system and the main factors affecting the accuracy of measurements are considered. The results of measurements of the activity of the source made for the BEST experiment are presented. The value of the source activity from calorimetric measurements was 3.41 MCi at the beginning of the experiment.

hep-ex

Modeling of a MeV-scale Particle Detector Based on Organic Liquid Scintillator

The detectors based on the liquid scintillator (LS) monitored by an array of photo-multiplier tubes (PMT) are often used in low energy experiments such as neutrino oscillation studies and search for dark matter. Detectors of this kind operate in an energy range spanning from hundreds of keV to a few GeV providing a few percent resolution at energies above 1 MeV and allowing to observe fine spectral features. This article gives a brief overview of relevant physical processes and introduces a new universal simulation tool LSMC (Liquid Scintillator Monte Carlo) for simulation of LS-based detectors equipped with PMT arrays. This tool is based on the Geant4 framework and provides supplementing functionality for ease of configuration and comprehensive output. The usage of LSMC is illustrated by modeling and optimization of a compact detector prototype currently being built at Baksan Neutrino Observatory.

physics.ins-det

On the gallium experiment BEST-2 with a $^{65}$Zn source to search for neutrino oscillations on a short baseline

In the paper is considered the use of a , $^{65}$Zn source in the BEST-2 gallium experiment to constrain the regions of the allowed oscillation parameters. The required activity of the $^{65}$Zn source for the BEST-2 experiment, its size, effect on the results of oscillatory measurements, as well as the possibility of production such a source are calculated. Schemes of measurements execution are considered.

physics.ins-det

Light Sterile Neutrinos: A White Paper

This white paper addresses the hypothesis of light sterile neutrinos based on recent anomalies observed in neutrino experiments and the latest astrophysical data.

hep-ph

Fast Neutron Detection with 6Li-loaded Liquid Scintillator

We report on the development of a fast neutron detector using a liquid scintillator doped with enriched Li-6. The lithium was introduced in the form of an aqueous LiCl micro-emulsion with a di-isopropylnaphthalene-based liquid scintillator. A Li-6 concentration of 0.15 % by weight was obtained. A 125 mL glass cell was filled with the scintillator and irradiated with fission-source neutrons. Fast neutrons may produce recoil protons in the scintillator, and those neutrons that thermalize within the detector volume can be captured on the Li-6. The energy of the neutron may be determined by the light output from recoiling protons, and the capture of the delayed thermal neutron reduces background events. In this paper, we discuss the development of this 6Li-loaded liquid scintillator, demonstrate the operation of it in a detector, and compare its efficiency and capture lifetime with Monte Carlo simulations. Data from a boron-loaded plastic scintillator were acquired for comparison. We also present a pulse-shape discrimination method for differentiating between electronic and nuclear recoil events based on the Matusita distance between a normalized observed waveform and nuclear and electronic recoil template waveforms. The details of the measurements are discussed along with specifics of the data analysis and its comparison with the Monte Carlo simulation.

physics.ins-det

Gallium experiments with artificial neutrino sources as a tool for investigation of transition to sterile states

We propose to place a very intense source of 51Cr at the center of a 50-tonne target of gallium metal that is divided into two concentric spherical zones and to measure the neutrino capture rate in each zone. This experiment can set limits on transitions from active to sterile neutrinos with Delta m^2 ~ 1 eV^2 with a sensitivity to disappearance of electron neutrinos of a few percent.

nucl-ex

Measurement of the solar neutrino capture rate with gallium metal. III: Results for the 2002--2007 data-taking period

The Russian-American experiment SAGE began to measure the solar neutrino capture rate with a target of gallium metal in Dec. 1989. Measurements have continued with only a few brief interruptions since that time. We give here the experimental improvements in SAGE since its last published data summary in Dec. 2001. Assuming the solar neutrino production rate was constant during the period of data collection, combined analysis of 168 extractions through Dec. 2007 gives a capture rate of solar neutrinos with energy more than 233 keV of 65.4 (+3.1)(-3.0) (stat) (+2.6)(-2.8) (syst) SNU. The weighted average of the results of all three Ga solar neutrino experiments, SAGE, Gallex, and GNO, is now 66.1 +/- 3.1 SNU, where statistical and systematic uncertainties have been combined in quadrature. During the recent period of data collection a new test of SAGE was made with a reactor-produced 37Ar neutrino source. The ratio of observed to calculated rates in this experiment, combined with the measured rates in the three prior 51Cr neutrino-source experiments with Ga, is 0.87 +/- 0.05. A probable explanation for this low result is that the cross section for neutrino capture by the two lowest-lying excited states in 71Ge has been overestimated. If we assume these cross sections are zero, then the standard solar model including neutrino oscillations predicts a total capture rate in Ga in the range of 63-66 SNU with an uncertainty of about 4%, in good agreement with experiment. We derive the current value of the neutrino flux produced in the Sun by the proton-proton fusion reaction to be (6.0 +/- 0.8) x 10^(10)/(cm^2 s), which agrees well with the pp flux predicted by the standard solar model. Finally, we show that the data are consistent with the assumption that the solar neutrino production rate is constant in time.

nucl-ex

Comparative analysis of spectra of the background of the proportional counter filled with Kr, enriched in Kr-78, and with Kr of natural content

The results of the experiment searching for 2K-capture with large low-background proportional counter are presented. The comparison of spectra of the background of the proportional counter filled with Kr enriched in $^{78}$Kr (8400 hr) and with natural Kr (3039 hr) is given. A new limit on the half-life of $^{78}$Kr with regard to 2K-capture, T$_{1/2}\geq2.0\cdot10^{21}$ yrs (95% C.L.) has been obtained.

nucl-ex

Radiochemical solar neutrino experiments

Radiochemical experiments have been crucial to solar neutrino research. Even today, they provide the only direct measurement of the rate of the proton-proton fusion reaction, p + p --> d + e^+ + nu_e, which generates most of the Sun's energy. We first give a little history of radiochemical solar neutrino experiments with emphasis on the gallium experiment SAGE -- the only currently operating detector of this type. The combined result of all data from the Ga experiments is a capture rate of 67.6 +/- 3.7 SNU. For comparison to theory, we use the calculated flux at the Sun from a standard solar model, take into account neutrino propagation from the Sun to the Earth and the results of neutrino source experiments with Ga, and obtain 67.3 ^{+3.9}_{-3.5} SNU. Using the data from all solar neutrino experiments we calculate an electron neutrino pp flux at the earth of (3.41 ^{+0.76}_{-0.77}) x 10^{10}/(cm^2-s), which agrees well with the prediction from a detailed solar model of (3.30 ^{+0.13} _{-0.14}) x 10^{10}/(cm^2-s). Four tests of the Ga experiments have been carried out with very intense reactor-produced neutrino sources and the ratio of observed to calculated rates is 0.88 +/- 0.05. One explanation for this unexpectedly low result is that the cross section for neutrino capture by the two lowest-lying excited states in 71Ge has been overestimated. We end with consideration of possible time variation in the Ga experiments and an enumeration of other possible radiochemical experiments that might have been.

nucl-ex

Measurement of Neutron Background at the Pyhasalmi mine for CUPP Project, Finland

A natural neutron flux is one of significant kind of background in high-sensitive underground experiments. Therefore, when scheduling a delicate underground measurements one needs to measure neutron background. Deep underground the most significant source of neutrons are the U-Th natural radioactive chains giving a fission spectrum with the temperature of 2-3 MeV. Another source is the U-Th alpha-reactions on light nuclei of mine rock giving neutrons with different spectra in the 1-15 MeV energy region. Normal basalt mine rocks contain 1 ppm g/g of U-238 and less. Deep underground those rocks produce natural neutron fluxes of 10^{-7} - 10^{-6} cm^{-2}s^{-1} above 1 MeV. To measure such a background one needs a special techniques. In the Institute for Nuclear Research, Moscow, the neutron spectrometer was developed and built which is sensitive to such a low neutron fluxes. At the end of 2001 the collection of neutron data at the Pyhasalmi mine was started for the CUPP project. During 2002 the background and rough energy spectra of neutron at underground levels 410, 660, 990 and 1410 m were measured. The result of the measurement of the neutron background at different levels of the Pyhasalmi mine is presented and discussed. Data analysis is performed in different energy ranges from thermal neutrons up to 25 MeV and above.

nucl-ex

The BNO-LNGS joint measurement of the solar neutrino capture rate in 71Ga

We describe a cooperative measurement of the capture rate of solar neutrinos by the reaction 71Ga(ν_e,e^-)71Ge. Extractions were made from a portion of the gallium target in the Russian-American Gallium Experiment SAGE and the extraction samples were transported to the Gran Sasso laboratory for synthesis and counting at the Gallium Neutrino Observatory GNO. Six extractions of this type were made and the resultant solar neutrino capture rate was 64 ^{+24}_{-22} SNU, which agrees well with the overall result of the gallium experiments. The major purpose of this experiment was to make it possible for SAGE to continue their regular schedule of monthly solar neutrino extractions without interruption while a separate experiment was underway to measure the response of 71Ga to neutrinos from an 37Ar source. As side benefits, this experiment proved the feasibility of long-distance sample transport in ultralow background radiochemical experiments and familiarized each group with the methods and techniques of the other.

nucl-ex

Measurement of the response of a Ga solar neutrino experiment to neutrinos from an 37Ar source

An intense source of 37Ar was produced by the (n,alpha) reaction on 40Ca by irradiating 330 kg of calcium oxide in the fast neutron breeder reactor at Zarechny, Russia. The 37Ar was released from the solid target by dissolution in acid, collected from this solution, purified, sealed into a small source, and brought to the Baksan Neutrino Observatory where it was used to irradiate 13 tonnes of gallium metal in the Russian-American gallium solar neutrino experiment SAGE. Ten exposures of the gallium to the source, whose initial strength was 409 +/- 2 kCi, were carried out during the period April to September 2004. The 71Ge produced by the reaction 71Ga(nu_e,e^-)71Ge was extracted, purified, and counted. The measured production rate was 11.0 ^+1.0 _-0.9 (stat) +/- 0.6 (syst) atoms of 71Ge/d, which is 0.79 ^+0.09_-0.10 of the theoretically calculated production rate. When all neutrino source experiments with gallium are considered together, there is an indication the theoretical cross section has been overestimated.

nucl-ex