SearcharxivSearch

arXiv subjects

V. Oleynikov

Publications and source records attributed to V. Oleynikov.

15 recordsLinked to original sources

Characterization of argon recoils at the keV scale with ReD and ReD+

The ReD experiment measured the ionization yield Qy of argon for nuclear recoils in the 2-10 keV range using a dual-phase Time Projection Chamber irradiated with neutrons from a Cf-252 fission source. The measurement extends coverage below 7 keV, confirms consistency with previous data above 7 keV, and indicates a higher Qy at lower energies. These results are relevant for argon-based experiments searching for dark matter in the form of low-mass Weakly Interacting Massive Particles, which are very sensitive to the modeling of the detector response in this energy range.

hep-ex

Characterization of the ionization response of argon to nuclear recoils at the keV scale with the ReD experiment

In the recent years, argon-based experiments looking for Dark Matter in the Universe have explored the non-standard scenario in which Dark Matter is made by low-mass Weakly Interacting Massive Particles, of mass in the range of 1-10 GeV instead of the canonical hundreds of GeV. Detecting such particles is challenging, as their expected signatures are nuclear recoils with energies below 10 keV, observable solely via ionization. This necessitates a precise understanding of the detector response in this energy regime, which remains incomplete for argon. To address this, the ReD experiment was developed within the framework of the DarkSide-20k Collaboration to produce and characterize few-keV nuclear recoils. A compact dual-phase argon Time Projection Chamber (TPC) was irradiated with neutrons from a Cf252 source, to produce Ar recoils in the energy range of interest via (n,n') elastic scattering. A downstream spectrometer composed of 18 plastic scintillators detected the neutrons scattered off Ar nuclei, enabling recoil energy reconstruction via two-body kinematics. The ionization yield Qy of argon, defined as the number of electrons produced per unit energy deposit, was measured in a model-independent way between 2 and 10 keV. These measurements extend direct experimental coverage well below the previous limit of approximately 7 keV. The results are consistent with existing data above 7 keV, while they indicate a higher Qy at lower energies.

nucl-ex

First observation of neutral bremsstrahlung electroluminescence in liquid argon

A recent discovery of additional mechanism of electroluminescence (EL) in noble gases due to the neutral bremsstrahlung (NBrS) effect led to a prediction that NBrS EL should be present in noble liquids as well. A theoretical model of NBrS EL in noble liquids was developed accordingly in the frameworks of Cohen-Lekner and Atrazhev. In this work, we confirm this prediction: for the first time, visible-range EL has been observed in liquid argon at electric fields reaching 90~kV/cm, using Gas Electron Multiplier (GEM) and Thick GEM (THGEM) structures. Absolute light yields of the EL were measured and found to be in excellent agreement with the theory, provided that the momentum-transfer cross section of electron scattering is used for calculation of NBrS cross section (instead of the energy-transfer one).

physics.ins-det

Possible evidence for the production of Ar$_2^{*-}$ metastable negative molecular ions in gaseous argon of two-phase detectors for dark matter searches

Our recent studies of electroluminescence (EL) properties in two-phase argon detectors for dark matter searches have revealed the presence of unusual delayed pulses in the EL signal in the form of two slow components with time constants of about 5 and 50 $μ$s. These components were shown to be present in the charge signal itself, which clearly indicates that drifting electrons are temporarily trapped on two states of metastable negative argon ions which have never been observed before. In this work, using the pressure dependence of the ratio of slow component contributions measured in experiment, it is deduced that these states are those of two types of metastable negative molecular ions, $\mathrm{Ar}_2^{*-}(b \ ^4Σ_u^-)$ and $\mathrm{Ar}_2^{*-}(a \ ^4Σ_g^+)$ for the higher and lower energy level respectively.

physics.ins-det

Unraveling the puzzle of slow components in gaseous argon of two-phase detectors for dark matter searches using Thick Gas Electron Multiplier

The effect of proportional electroluminescence (EL) is used to record the primary ionization signal (S2) in the gas phase of two-phase argon detectors for dark matter particle (WIMP) searches and low-energy neutrino experiments. Our previous studies of EL time properties revealed the presence of two unusual slow components in S2 signal of two-phase argon detector, with time constants of about 4-5 $μ$s and 50 $μ$s. The puzzle of slow components is that their time constants and contributions to the overall signal increase with electric field (starting from a certain threshold), which cannot be explained by any of the known mechanisms of photon and electron emission in two-phase media. There are indications that these slow components result from delayed electrons, temporarily trapped during their drift in the EL gap on metastable negative argon ions of yet unknown nature. In this work, this hypothesis is confirmed by studying the time properties of electroluminescence in a Thick Gas Electron Multiplier (THGEM) coupled to the EL gap of two-phase argon detector. In particular, an unusual slow component in EL signal, similar to that observed in the EL gap, was observed in THGEM itself. In addition, with the help of THGEM operated in electron multiplication mode, the slow component was observed directly in the charge signal, confirming the effect of trapped electrons in S2 signal. These results will help to unravel the puzzle of slow components in two-phase argon detectors and thus to understand the background in low-mass WIMP searches.

physics.ins-det

Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches

Proportional electroluminescence (EL) in noble gases is a physical process routinely used in two-phase (liquid-gas) detectors for low-energy astroparticle-physics experiments. In this work, the time properties of visible-light EL in two-phase argon detectors have been systematically studied for the first time. In particular, two unusual slow components in the EL signal, with their contributions and time constants increasing with electric field, were observed. This puzzling property is not expected in any of the known mechanisms of photon and electron emission in two-phase media. Time constants of these components is about 4-5 $μ$s and 50 $μ$s. In addition, a specific threshold behavior of the slow components was revealed: they emerged at a threshold in reduced electric field of 4.8 $\pm$ 0.2 Td regardless of the gas phase density, which is about 1 Td above the onset of standard (excimer) EL. There is a conspicuous similarity between this threshold and reduced field threshold of EL in NIR occurring via higher atomic excited states Ar$^{*}(3p^{5}4p)$. An unexpected temperature dependence of slow components was also observed: their contribution decreased with temperature, practically disappearing at room temperature. We show that the puzzling properties of slow components can be explained in the framework of hypothesis that these are produced in the charge signal itself due to trapping of drifting electrons on metastable negative argon ions.

physics.ins-det

Study of visible-light emission in pure and methane-doped liquid argon

In liquid argon TPCs for dark matter search and neutrino detection experiments, primary scintillation light is used as a prompt signal of particle scattering, being intensively produced in the vacuum ultraviolet (VUV) due to excimer emission mechanism. On the other hand, there were indications on the production of visible-light emission in liquid argon, albeit at a much lower intensity, the origin of which is still not clear. The closely related issue is visible-light emission in liquid argon doped with methane, the interest in which is due to the possible use in neutron veto detectors for those experiments. In this work we study in detail the properties of such light emission in pure liquid argon and its mixtures with methane. In particular, the absolute photon yield of visible-light emission in pure liquid argon was measured to be about 200 and 90 photon/MeV for X-rays and alpha particles respectively. In liquid argon doped with methane the photon yield dropped down significantly, by about an order of magnitude at a methane molar content varying from 0.01 to 1%, and then almost did not change when further increasing the methane content up to 10%.

physics.ins-det

Performance of the ReD TPC, a novel double-phase LAr detector with Silicon Photomultiplier Readout

A double-phase argon Time Projection Chamber (TPC), with an active mass of 185 g, has been designed and constructed for the Recoil Directionality (ReD) experiment. The aim of the ReD project is to investigate the directional sensitivity of argon-based TPCs via columnar recombination to nuclear recoils in the energy range of interest (20-200 keV$_{nr}$) for direct dark matter searches. The key novel feature of the ReD TPC is a readout system based on cryogenic Silicon Photomultipliers, which are employed and operated continuously for the first time in an argon TPC. Over the course of six months, the ReD TPC was commissioned and characterised under various operating conditions using $γ$-ray and neutron sources, demonstrating remarkable stability of the optical sensors and reproducibility of the results. The scintillation gain and ionisation amplification of the TPC were measured to be $g_1 = (0.194 \pm 0.013)$ PE/photon and $g_2 = (20.0 \pm 0.9)$ PE/electron, respectively. The ratio of the ionisation to scintillation signals (S2/S1), instrumental for the positive identification of a candidate directional signal induced by WIMPs, has been investigated for both nuclear and electron recoils. At a drift field of 183 V/cm, an S2/S1 dispersion of 12% was measured for nuclear recoils of approximately 60-90 keV$_{nr}$, as compared to 18% for electron recoils depositing 60 keV of energy. The detector performance reported here meets the requirements needed to achieve the principal scientific goals of the ReD experiment in the search for a directional effect due to columnar recombination. A phenomenological parameterisation of the recombination probability in LAr is presented and employed for modeling the dependence of scintillation quenching and charge yield on the drift field for electron recoils between 50-500 keV and fields up to 1000 V/cm.

physics.ins-det

Observation of unusual slow components in electroluminescence signal of two-phase argon detector

Proportional electroluminescence (EL) in noble gases is used in two-phase detectors for dark matter search to record ionization signals in the gas phase induced by particle scattering in the liquid phase (S2 signals). In this work, the EL pulse-shapes in a two-phase argon detector have for the first time been studied systematically in a wide range of reduced electric field, varying from 3 to 9 Td. The pulse-shapes were studied at different readout configurations and spectral ranges: using cryogenic PMTs and SiPMs, with and without a wavelength shifter (WLS), in the VUV and visible range. We observed the fast component and two unusual slow components, with time constants of about 5 $μ$s and 40 $μ$s. The unusual characteristic property of slow components was that their contribution and time constants increased with electric field.

physics.ins-det

Observation of primary scintillations in the visible range in liquid argon doped with methane

Neutron veto detector based on liquid scintillator containing hydrogen atoms is an integral part of any underground experiment for dark matter search. So far, a flammable mixture of liquid hydrocarbons was used as a liquid scintillator in such detectors. A safe alternative might be a liquid scintillator based on liquid argon doped with methane. In this work, we have studied the primary scintillations in pure liquid argon and its mixtures with methane, the CH4 content varying from 100 ppm to 5%. The primary scintillations have for the first time been observed in liquid argon doped with methane, in the visible and near infrared range, and their relative light yields have been measured as a function of the CH4 content.

physics.ins-det

Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications

We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detection science are discussed, including those in two-phase dark matter detectors.

physics.ins-det

Revealing neutral bremsstrahlung in two-phase argon electroluminescence

Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed that proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter being in turn produced by drifting electrons. In this work we consider an additional mechanism of proportional electroluminescence, namely that of bremsstrahlung of drifting electrons scattered on neutral atoms (so-called neutral bremsstrahlung); it is systemically studied here both theoretically and experimentally. In particular, the absolute EL yield has for the first time been measured in pure gaseous argon in the two-phase mode, using a dedicated two-phase detector with EL gap optically read out by cryogenic PMTs and SiPMs. We show that the neutral bremsstrahlung effect can explain two intriguing observations in EL radiation: that of the substantial contribution of the non-VUV spectral component, extending from the UV to NIR, and that of the photon emission at lower electric fields, below the Ar excitation threshold. Possible applications of neutral bremsstrahlung effect in two-phase dark matter detectors are discussed.

physics.ins-det

Characterization of a 109Cd gamma-ray source for the two-phase argon detector

At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission spectrum of the $^{109}$Cd source was measured using YAP:Ce scintillator and high-purity germanium (HPGe) detectors. It is shown that the $^{109}$Cd source, equipped with a W substrate and a Cu filter, can provide a complete set of gamma-ray lines, ranging from 8 to 90 keV, for the energy calibration of two-phase detectors. These measurements allowed us to successfully quantify the shape of the amplitude spectra observed in the two-phase argon detector when irradiated with the $^{109}$Cd source.

physics.ins-det

Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap

A measurement of ionization yields in noble-gas liquids is relevant to the energy calibration of nuclear recoil detectors for dark matter search and coherent neutrino-nucleus scattering experiments. In this work we further study the ionization yield of nuclear recoils in liquid Ar, using a two-phase detector with an electroluminescence gap and DD neutron generator. The ionization yields of nuclear recoils in liquid Ar were measured at 233 keV and electric fields of 0.56 and 0.62 kV/cm; their values amounted to 5.9 $\pm$ 0.8 and 7.4 $\pm$ 1 e$^-$/keV, respectively. The characteristic dependences of the ionization yield on energy and electric field were determined, while comparing the results obtained to those at lower energies and higher fields.

astro-ph.IM

Further studies of proportional electroluminescence in two-phase argon

The study of proportional electroluminescence in two-phase argon is relevant in the field of noble-gas liquid detectors for dark matter search and low-energy neutrino experiments. In this work, we continued to study proportional electroluminescence (EL) in two-phase argon doped with a minor (9 ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We confirmed the effect of enhancement of the EL yield, as well as the presence of non-VUV component in addition to that of VUV, in proportional electroluminescence in two-phase Ar. On the other hand, the contribution of non-VUV component determined here within the model of N2 emission in the UV, turned out to be insufficient to explain the EL yield enhancement effect. Accordingly, the problem of proportional electroluminescence in two-phase Ar remains unresolved.

astro-ph.IM