Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches

Abstract

Proportional electroluminescence (EL) in noble gases is a physical process routinely used in two-phase (liquid-gas) detectors for low-energy astroparticle-physics experiments. In this work, the time properties of visible-light EL in two-phase argon detectors have been systematically studied for the first time. In particular, two unusual slow components in the EL signal, with their contributions and time constants increasing with electric field, were observed. This puzzling property is not expected in any of the known mechanisms of photon and electron emission in two-phase media. Time constants of these components is about 4-5 $\mu$s and 50 $\mu$s. In addition, a specific threshold behavior of the slow components was revealed: they emerged at a threshold in reduced electric field of 4.8 $\pm$ 0.2 Td regardless of the gas phase density, which is about 1 Td above the onset of standard (excimer) EL. There is a conspicuous similarity between this threshold and reduced field threshold of EL in NIR occurring via higher atomic excited states Ar$^{*}(3p^{5}4p)$. An unexpected temperature dependence of slow components was also observed: their contribution decreased with temperature, practically disappearing at room temperature. We show that the puzzling properties of slow components can be explained in the framework of hypothesis that these are produced in the charge signal itself due to trapping of drifting electrons on metastable negative argon ions.

Explore related subjects

Keep this discovery

BibTeXRIS

A. Buzulutskov, E. Frolov, E. Borisova, V. Nosov, V. Oleynikov, A. Sokolov. 2022-06-01. Puzzling time properties of proportional electroluminescence in two-phase argon detectors for dark matter searches. https://doi.org/10.1140/epjc/s10052-022-10792-1

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det