Searcharxiv⌕ Search

arXiv subjects

V. Yakovlev

Publications and source records attributed to V. Yakovlev.

At least 37 records · Page 2Linked to original sources

On the Phase Grouping Mechanism for a Magnetron Coherent Oscillation

CW magnetrons, developed for industrial heaters, but driven by an injection-locking signal were suggested to power Superconducting RF (SRF) cavities due to higher efficiency and lower cost of generated RF power per Watt than traditionally used RF sources (klystrons, IOTs, solid-state amplifiers). When the magnetrons are intended to feed Room Temperature (RT) cavities, the injected phase or frequency locking signal may provide required phase or frequency stability of the accelerating field. However, when the magnetron RF sources are intended to feed high Q-factor SRF cavities, the sources must be controlled in phase and power in a wide bandwidth to compensate parasitic phase and amplitude modulations caused by microphonics. In dependence on parameters of magnetron and the injection-locking signal one can choose regime most suitable for feeding SRF cavities, enabling magnetron almost coherent oscillation at the wide bandwidth of control. A novel approach considering magnetrons as quasi-coherent or coherent RF generators enables choosing the tube parameters and operation most suitable for various SRF accelerators.

physics.acc-ph↗

Optimization of a traveling wave superconducting radiofrequency cavity for upgrading the International Linear Collider

The Standing Wave (SW) TESLA niobium-based superconducting radio frequency structure is limited to an accelerating gradient of about 50 MV/m by the critical RF magnetic field. To break through this barrier, we explore the option of niobium-based traveling wave (TW) structures. Optimization of TW structures was done considering experimentally known limiting electric and magnetic fields. It is shown that a TW structure can have an accelerating gradient above 70 MeV/m that is about 1.5 times higher than contemporary standing wave structures with the same critical magnetic field. The other benefit of TW structures shown is R/Q about 2 times higher than TESLA structure that reduces the dynamic heat load by a factor of 2. A method is proposed how to make TW structures multipactor-free. Some design proposals are offered to facilitate fabrication. Further increase of the real-estate gradient (equivalent to 80 MV/m active gradient) is also possible by increasing the length of the accelerating structure because of higher group velocity and cell-to-cell coupling. Realization of this work opens paths to ILC energy upgrades beyond 1 TeV to 3 TeV in competition with CLIC. The paper will discuss corresponding opportunities and challenges.

physics.acc-ph↗

Ring-Based Electron Cooling System for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction linac technology with a dc electron beam. The system would operate in a full energy range of proton beams (100 - 270 GeV) and would provide 50-100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30$\%$. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1-2 hours.

physics.acc-ph↗

Stimulated Generation of Magnetrons powered below the Self-Excitation Threshold Voltage

Modern CW or pulsed superconducting accelerators of megawatts beams require efficient RF sources controllable in phase and power. It is desirable to have an individual RF power source with power up to hundreds of kW for each Superconductive RF (SRF) cavity. For pulsed accelerators the pulse duration in millisecond range is required. The efficiency of the traditional RF sources (klystrons, IOTs, solid-state amplifiers) in comparison to magnetrons is lower and the cost of unit of RF power is significantly higher. Typically, the cost of RF sources and their operation is a significant part of the total project cost and operation. The magnetron-based RF sources with a cost of power unit of 1-3 dollars per Watt would significantly reduce the capital and operation costs in comparison with the traditional RF sources. This arouses interest in magnetron RF sources for use in modern accelerators. A recently developed kinetic model describing the principle of magnetron operation and subsequent experiments resulted in an innovative technique producing the "stimulated" generation of magnetrons powered below the self-excitation threshold voltage. The magnetron operation in this regime is stable, low noise, controllable in phase and power, and provides higher efficiency than other types of RF power sources. It allows operation in CW and pulse modes (at large duty factor). For pulsed operation this technique does not require pulse modulators to form RF pulses. It also looks as a promising opportunity to extend magnetron life time. The developed technique, its experimental verification and a brief explanation of the kinetic model substantiating the technique are presented and discussed in this article.

physics.acc-ph↗

Improved Magnetron Stability And Reduced Noise In Efficient Transmitters For Superconducting Accelerators

State of the art high-current superconducting accelerators require efficient RF sources with a fast dynamic phase and power control. This allows for compensation of the phase and amplitude deviations of the accelerating voltage in the Superconducting RF (SRF) cavities caused by microphonics, etc. Efficient magnetron transmitters with fast phase and power control are attractive RF sources for this application. They are more cost effective than traditional RF sources such as klystrons, IOTs and solid-state amplifiers used with large scale accelerator projects. However, unlike traditional RF sources, controlled magnetrons operate as forced oscillators. Study of the impact of the controlling signal on magnetron stability, noise and efficiency is therefore important. This paper discusses experiments with 2.45 GHz, 1 kW tubes and verifies our analytical model which is based on the charge drift approximation.

physics.acc-ph↗

Phase Grouping of Larmor Electrons By a Synchronous Wave In Controlled Magnetrons

A simplified analytical model based on the charge drift approximation has been developed. It considers the resonant interaction of the synchronous wave with the flow of Larmor electrons in a magnetron. The model predicts stable coherent generation of the tube above and below the threshold of self-excitation. This occurs if the magnetron is driven by a sufficient resonant injected signal (up to -10 dB). The model substantiates precise stability, high efficiency and low noise at the range of the magnetron power control over 10 dB by variation of the magnetron current. The model and the verifying experiments with 2.45 GHz, 1 kW magnetrons are discussed.

physics.acc-ph↗

Methods of phase and power control in magnetron transmitters for superconducting accelerators

Various methods of phase and power control in magnetron RF sources of superconducting accelerators intended for ADS-class projects were recently developed and studied with conventional 2.45 GHz, 1 kW, CW magnetrons operating in pulsed and CW regimes. Magnetron transmitters excited by a resonant (injection-locking) phasemodulated signal can provide phase and power control with the rates required for precise stabilization of phase and amplitude of the accelerating field in Superconducting RF (SRF) cavities of the intensity-frontier accelerators. An innovative technique that can significantly increase the magnetron transmitter efficiency at the widerange power control required for superconducting accelerators was developed and verified with the 2.45 GHz magnetrons operating in CW and pulsed regimes. High efficiency magnetron transmitters of this type can significantly reduce the capital and operation costs of the ADSclass accelerator projects.

physics.acc-ph↗

Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\sim$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.

physics.acc-ph↗

Phase and Power Control in the RF Magnetron Power Stations of Superconducting Accelerators

Phase and power control methods that satisfy the requirements of superconducting accelerators to magnetron RF sources were considered by a simplified kinetic model of a magnetron driven by a resonant injected signal. The model predicting and explaining stable, low noise operation of the tube below the threshold of self-excitation (the Hatrree voltage in free run mode) at a highest efficiency, a wide range of power control and a wide-band phase control was well verified in experiments demonstrating capabilities of the magnetron transmitters for powering of state of the art superconducting accelerators. Descriptions of the kinetic model, the experimental verification and a conceptual scheme of the highly-efficient magnetron RF transmitter for the accelerators are presented and discussed.

physics.acc-ph↗

A Novel Technique of Power Control In Magnetron Transmitters For Intense Accelerators

A novel concept of a high-power magnetron transmitter allowing dynamic phase and power control at the frequency of locking signal is proposed. The transmitter compensating parasitic phase and amplitude modulations inherent in Superconducting RF (SRF) cavities within closed feedback loops is intended for powering of the intensity-frontier superconducting accelerators. The concept uses magnetrons driven by a sufficient resonant (injection-locking) signal and fed by the voltage which can be below the threshold of self-excitation. This provides an extended range of power control in a single magnetron at highest efficiency minimizing the cost of RF power unit and the operation cost. Proof-of-principle of the proposed concept demonstrated in pulsed and CW regimes with 2.45 GHz, 1kW magnetrons is discussed here. A conceptual scheme of the high-power transmitter allowing the dynamic wide-band phase and mid-frequency power controls is presented and discussed.

physics.acc-ph↗

Untrapped HOM Radiation Absorption in the LCLS-II Cryomodules

The superconducting cavities in the continuous wave (CW) linacs of LCLS-II are designed to operate at 2 K, where cooling costs are very expensive. One source of heat is presented by the higher order mode (HOM) power deposited by the beam. Due to the very short bunch length--especially in L3 the final linac--the LCLS-II beam spectrum extends into the terahertz range. Ceramic absorbers, at 70 K and located between cryomodules, are meant to absorb much of this power. In this report we perform two kinds of calculations to estimate the effectiveness of the absorbers and the amount of beam power that needs to be removed at 2 K.

physics.acc-ph↗

The Project-x Injector Experiment: A Novel High Performance Front-end For A Future High Power Proton Facility At Fermilab

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are carrying out a program of research and development aimed at integrated systems testing of critical components comprising the front end of Project X. This program, known as the Project X Injector Experiment (PXIE), is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. PXIE is currently under construction at Fermilab and will be completed over the period FY12-17. PXIE will include an H- ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

physics.acc-ph↗

Regime of a wideband phase-amplitude modulation in a CW magnetron transmitter with a phase control

A model of the CW high-power transmitter, utilizing frequency-locked magnetrons with a phase control studied initially as a prototype of controllable in phase and power an RF source for intensity-frontier superconducting linacs, was considered for telecommunication as a model of magnetron source, acceptable for a wideband phase-amplitude modulation at a precisely stable carrier frequency. The R&D conducted with CW, 2.45 GHz, 1 kW, microwave oven magnetrons demonstrated that the frequency locking of the magnetrons by the phase-modulated signal provides wideband phase and amplitude modulation at the modulating frequency at least up to 3 MHz and large magnitude, keeping the carrier frequency precisely stable, without broadening of the spectral line width. Performed experiments with power combining verified applicability of the transmitter based on the frequency-locked magnetrons for wideband phase and amplitude modulation, which may be used for telecommunication. Results of the experiments are described in the presented work.

physics.ins-det↗

Some wakefield effects in the superconducting RF cavities of LCLS-II

For LCLS-II we estimate the power of radiated wakefields generated in the SRF cavities (including the 3rd harmonic cavities) and in the end transitions. Much of this power will pass through and reflect in the strings of cryomodules that comprise linacs L1, L2, or L3. Presumably, some of it will be absorbed by the higher order mode (HOM) couplers, or by the absorbers at warmer temperatures situated between the cryomodules. We investigate where such power gets generated, but not where it ends up. As such the results can serve as a pessimistic calculation of the extra power that needs to be removed by the cryosystem. Finally, we also estimate---under the assumption that all the wake power ends up in the SRF walls---the wall heating and the extent of Cooper pair breaking in L3, where the bunch is most intense. Note that all calculations here are of single bunch effects; thus resonant interactions are not included.

physics.acc-ph↗

Project X: Accelerator Reference Design

Part 1 of "Project X: Accelerator Reference Design, Physics Opportunities, Broader Impacts". Part 1 contains the volume Preface and a description of the conceptual design for a high-intensity proton accelerator facility being developed to support a world-leading program of Intensity Frontier physics over the next two decades at Fermilab. Subjects covered include performance goals, the accelerator physics design, and the technological basis for such a facility. Part 2 is available as arXiv:1306.5009 [hep-ex] and Part 3 is available as arXiv:1306.5024 [physics.acc-ph].

physics.acc-ph↗

Design of MEBT for the Project X Injector Experiment at Fermilab

The Project X Injector Experiment (PXIE), a test bed for the Project X front end, will be completed at Fermilab at FY12-16. One of the challenging goals of PXIE is demonstration of the capability to form a 1 mA H- beam with an arbitrary selected bunch pattern from the initially 5 mA 162.5 MHz CW train. The bunch selection will be made in the Medium Energy Beam Transport (MEBT) at 2.1 MeV by diverting undesired bunches to an absorber. This paper presents the MEBT scheme and describes development of its elements, including the kickers and absorber.

physics.acc-ph↗

High Gradient Tests of the Fermilab SSR1 Cavity

In Fermilab we are build and tested several superconducting Single Spoke Resonators (SSR1, β=0.22) which can be used for acceleration of low beta ions. Fist two cavities performed very well during cold test in Vertical Test Station at FNAL. One dressed cavity was also tested successfully in Horizontal Test Station. Currently we are building 8 cavity cryomodule for PIXIE project. Additional 10 cavities were manufactured in the industry and on-going cold test results will be presented in this poster.

physics.acc-ph↗

A high resolution cavity BPM for the CLIC Test Facility

In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

physics.acc-ph↗