SearcharxivSearch

arXiv subjects

Valentina Novati

Publications and source records attributed to Valentina Novati.

5 recordsLinked to original sources

Characterization of Aluminum Microwave SQUID Multiplexers for CE$\nu$NS Detection

We present the design, fabrication, and characterization of an aluminum-based six-channel microwave SQUID multiplexer ($\mu$MUX) prototype for transition-edge sensor (TES) readout in the RICOCHET experiment. The device consists of aluminum coplanar-waveguide resonators and RF SQUIDs with Dolan-style Al/AlO$_x$/Al Josephson junctions. By measuring the resonator scattering parameters at a range of probe tone frequencies, powers, and flux bias points, we demonstrate agreement between the device response and existing multiplexer models. We also characterize the noise performance in both open-loop and flux-ramping modes. With a high electron mobility transistor (HEMT) amplifier, open-loop measurements yield a flux sensitivity of 1-1.5 $\mu\Phi_0/\sqrt{Hz}$. With flux-ramp modulation, low-frequency 1/f noise is suppressed, and the flux sensitivity is around 3-4 $\mu\Phi_0/\sqrt{Hz}$, corresponding to a current sensitivity of 24-33 $pA/\sqrt{Hz}$ at the input coil. We further demonstrate a reduction in readout noise by incorporating a Josephson traveling-wave parametric amplifier (JTWPA) between the $\mu$MUX and the HEMT. This achieves an open-loop flux sensitivity of 0.3-0.6 $\mu\Phi_0/\sqrt{Hz}$ and an effective system noise temperature below 1 K. These results establish aluminum $\mu$MUX devices as a viable and extensible readout technology for low-noise cryogenic detector arrays.

physics.ins-det

Performance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity

We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 589~meV~$\pm$~5~meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.92~eV~$\pm$~0.02~eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also measure a nominal phonon collection efficiency of 45\%~$\pm$~3\%~(stat.)~$\pm$~6\%~(syst.) in the best performing device, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation.

physics.ins-det

Characterization of mini-CryoCube detectors from the Ricochet experiment commissioning at the Institut Laue-Langevin

The Ricochet experiment aims to measure the coherent elastic neutrino-nucleus scattering process from antineutrinos emitted by a research nuclear reactor operated by the Institut Laue-Langevin (Grenoble, France). This article presents a description of the Ricochet experimental installation and the detector performance achieved during its commissioning with a mini-CryoCube module consisting of three 42-gram germanium cryogenic calorimeters. The baseline resolutions and background levels are reported both during reactor-on and reactor-off periods, and as noise mitigation techniques were improved. A baseline resolution of 40 eV electron equivalent was achieved for the ionization channel after setup improvements, and the phonon channel resolutions ranged from 50 to 80 eV of total phonon energy. In the energy region from 2 to 7 keV, a nuclear recoil rate of 15(2) events/(kg day keV) is measured during the reactor-off period selecting events in coincidence with muon veto signals. This rate is in agreement with the cosmogenic neutron rate calculated from GEANT4 simulations. After the rejection of events in coincidence with signals in the muon veto detectors, a combined 90% C.L. limit on the nuclear recoil background of < 9 events/(kg day keV) is obtained in that energy region during the reactor-on period, which is compatible with our GEANT4 model calculation corresponding to a total rate of 5 events/(kg day keV). The sensitivity of this analysis was however found to be limited by a surface event contamination which is currently being addressed by the Ricochet Collaboration with upgraded detectors.

hep-ex

Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $\sigma_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.

physics.ins-det

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

hep-ex