SearcharxivSearch

arXiv subjects

Valerio Biancalana

Publications and source records attributed to Valerio Biancalana.

At least 19 recordsLinked to original sources

Data-driven synthesis of high-fidelity triaxial magnetic waveforms for quantum control

We present a system for generating arbitrary, triaxial magnetic waveforms with a spectral content spanning from DC to tens of kHz, a critical capability for quantum control and spin manipulation. To compensate for amplifier-coil dynamics, we implement a data-driven approach to identify a numerical compensation model. The method parametrizes the system response using a Finite Impulse Response (FIR) filter calibrated on the specific waveform to be generated. The application of a driving signal designed via frequency-domain inversion of the identified model enables the synthesis of complex field sequences with sharp transitions between static and single- or multi-frequency temporal segments. The work is validated with experimental results demonstrating waveform fidelity and transient performance, thereby showcasing the precision and feasibility of the method.

physics.ins-det

Multipassage Landau-Zener tunneling oscillations in transverse/longitudinal dual dressing of atomic qubits

We investigate the time evolution of a non-resonant dressed-atom qubit in an XZ original configuration. It is composed of two electromagnetic fields, one oscillating parallel and the other orthogonal to the quantisation magnetic static field. The experiments are performed in rubidium and caesium atomic magnetometers, confined in a magneto-optical trap and in a vapour cell, respectively. Static fields in the $μ$T range and kHz oscillating fields with large Rabi frequencies are applied. This dual-dressing configuration is an extension of the Landau-Zener multipassage interferometry in the presence of an additional dressing field controlling the tunneling process by its amplitude and phase. Our measurement of the qubit coherence introduces additional features to the transition probability readout of standard interferometry. The coherence time evolution is characterized by oscillations at several frequencies, each of them produced by a different quantum contribution. Such frequency description introduces a new picture of the qubit multipassage evolution. Because the present low-frequency dressing operation does not fall within the standard Floquet engineering paradigm based on the high-frequency expansion, we develop an ad-hoc dressing perturbation treatment. Numerical simulations support the adiabatic and non-adiabatic qubit evolution.

quant-ph

Tri-axial time-dependent magnetic field calibrated in-situ by harmonic analysis of adiabatically evolving atomic spins

We introduce a methodology to calibrate in situ a set of coils generating bi- or tri-axial magnetic fields, at frequencies where a calibration performed under static conditions would be inaccurate. The methodology uses harmonic analysis of one component of the magnetization of an atomic sample whose spins adiabatically follow an ad hoc applied time-dependent field. The procedure enables the identification of phases and amplitudes of the coil currents required to produce a dynamic magnetic field with the assigned polarization. This determines coil constants that can be subsequently used to produce arbitrary three-dimensional time-dependent fields.

physics.ins-det

A Wearable Wireless Magnetic Eye-Tracker, in-vitro and in-vivo Tests

A wireless, wearable magnetic eye tracker is described and characterized. The proposed instrumentation enables simultaneous evaluation of eye and head angular displacements. Such a system can be used to determine the absolute gaze direction as well as to analyze spontaneous eye re-orientation in response to stimuli consisting in head rotations. The latter feature has implications to analyze the vestibulo-ocular reflex and constitutes an interesting opportunity to develop medical (oto-neurological) diagnostics. Details of data analysis are reported together with some results obtained in-vivo or with simple mechanical simulators that enable measurements under controlled conditions.

physics.med-ph

A non-inductive magnetic eye-tracker: from dipole tracking to gaze retrieval

We analyze the information that can be retrieved from the tracking parameters produced by an innovative wearable eye tracker. The latter is based on a permanent-magnet marked corneal lens and by an array of magnetoresistive detectors that measure the magnetostatic field in several positions in the eye proximity. We demonstrate that, despite missing information due to the axial symmetry of the measured field, physiological constraints or measurement conditions make possible to infer complete eye-pose data. Angular precision and accuracy achieved with the current prototypical device are also assessed and briefly discussed. The results show that the instrumentation considered is suitable as a new, moderately invasive medical diagnostics for the characterization of ocular movements and associated disorders.

physics.med-ph

An innovative eye-tracker. Main features and demonstrative tests

We present a set of results obtained with an innovative eye-tracker based on magnetic dipole localization by means of an array of magnetoresistive sensors. The system tracks both head and eye movements with a high rate (100-200 Sa/s) and in real time. A simple setup is arranged to simulate head and eye motions and to test the tracker performance under realistic conditions. Multimedia material is provided to substantiate and exemplify the results. A comparison with other available technologies for eye tracking is drawn, discussing advantages (e.g. precision) and disadvantages (e.g. invasivity) of the diverse approaches, the presented method standing out for low cost, robustness and relatively low invasivity.

physics.med-ph

Harmonic dual dressing of spin one-half systems

Controlled modifications of the quantum magnetic response are produced in dressed systems by a high frequency, strong and not-resonant electromagnetic field. This quantum control is greatly enhanced and enriched by the harmonic, commensurable and orthogonally oriented dual dressing theoretically discussed here. The secondary field enables a fine tuning of the qubit response, with control parameters amplitude, harmonic content, spatial orientation and phase relation. Our analysis is based on a perturbative approach and includes few numerical solutions. The long-time dynamics is described in terms of an anisotropic effective static magnetic field representing the handle for the system full engineering. Through a low-order harmonic mixing the bichromatic driving generates a rectified static field acting on the spin. The Zeeman response becomes anisotropic in a triaxial geometry and includes a quadratic contribution. Our dressing increases the two-level energy splitting, improving the spin detection sensitivity. On the low field direction it compensates the static fields applied in different geometries. A resonant spin exchange between two species having very different magnetic response as electron and nucleus is allowed by the dressing. The spin temporal evolution includes a micromotion at harmonics of the driving frequency whose role in the spin detection is examined and can be exploited in quantum information. The results presented here lay a foundation for additional applications to be harnessed in quantum simulations.

quant-ph

Spin dynamic response to a time dependent field

The dynamic response of a parametric system constituted by a spin precessing in a time dependent magnetic field is studied by means of a perturbative approach that unveils unexpected features, and is then experimentally validated. The first-order analysis puts in evidence different regimes: beside a tailorable low-pass-filter behaviour, a band-pass response with interesting potential applications emerges. Extending the analysis to the second perturbation order permits to study the response to generically oriented fields and to characterize several non-linear features in the behaviour of such kind of systems.

physics.app-ph

Studying and applying magnetic dressing with a Bell and Bloom magnetometer

The magnetic dressing phenomenon occurs when spins precessing in a static field (holding field) are subject to an additional, strong, alternating field. It is usually studied when such extra field is homogeneous and oscillates in one direction. We study the dynamics of spins under dressing condition in two unusual configurations. In the first instance, an inhomogeneous dressing field produces space dependent dressing phenomenon, which helps to operate the magnetometer in strongly inhomogeneous static field. In the second instance, beside the usual configuration with static and the strong orthogonal oscillating magnetic fields, we add a secondary oscillating field, which is perpendicular to both. The system shows novel and interesting features that are accurately explained and modelled theoretically. Possible applications of these novel features are briefly discussed.

physics.atom-ph

Validation of a fast and accurate magnetic tracker operating in the environmental field

We characterize the performance of a system based on a magnetoresistor array. This instrument is developed to map the magnetic field, and to track a dipolar magnetic source in the presence of a static homogeneous field. The position and orientation of the magnetic source with respect to the sensor frame is retrieved together with the orientation of the frame with respect to the environmental field. A nonlinear best-fit procedure is used, and its precision, time performance, and reliability are analyzed. This analysis is performed in view of the practical application for which the system is designed that is an eye-tracking diagnostics and rehabilitative tool for medical purposes, which require high speed ($\ge 100$~Sa/s) and sub-millimetric spatial resolution. A throughout investigation on the results makes it possible to list several observations, suggestions, and hints, which will be useful in the design of similar setups.

physics.app-ph

Fast, cheap, and scalable magnetic tracker with an array of magnetoresistors

We present the hardware of a cheap multi-sensor magnetometric setup where a relatively large set of magnetic field components is measured in several positions by calibrated magnetoresistive detectors. The setup is developed with the scope of mapping the (inhomogeneous) field generated by a known magnetic source, which is measured as superimposed to the (homogeneous) geomagnetic field. The final goal is to use the data produced by this hardware to reconstruct position and orientation of the magnetic source with respect to the sensor frame, simultaneously with the orientation of the frame with respect to the environmental field. Possible applications of the setup are shortly discussed, together with a synthetic description of the data elaboration and analysis.

physics.ins-det

Harmonic fine tuning and triaxial spatial anisotropy of dressed atomic spins

The addition of a weak oscillating field modifying strongly dressed spins enhances and enriches the system quantum dynamics. Through low-order harmonic mixing the bichromatic driving generates additional rectified static field acting on the spin system. The secondary field allows for a fine tuning of the atomic response and produces effects not accessible with a single dressing field, such as a spatial triaxial anisotropy of the spin coupling constants and acceleration of the spin dynamics. This tuning-dressed configuration introduces an extra handle for the system full engineering for quantum control applications. Tuning amplitude, harmonic content, spatial orientation and phase relation are control parameters. A theoretical analysis, based on perturbative approach, is experimentally validated by applying a bichromatic radiofrequency field to an optically pumped Cs atomic vapour. We measure the resonance shifts produced by tuning fields up to the third harmonic.

quant-ph

Ferromagnetic contamination of Ultra-Low-Field-NMR sample containers. Quantification of the problem and possible solutions

The presence of a weak remanence in Ultra-Low-Field (ULF) NMR sample containers is investigated on the basis of proton precession. The high-sensitivity magnetometer used for the NMR detection, enables simultaneously the measurement of the static field produced in the sample proximity by ferromagnetic contaminants. The presence of the latter is studied by high resolution chemical analyses of the surface, based on X-ray fluorescence spectroscopy and secondary ions mass spectroscopy. Methodologies to reduce the contamination are explored and characterized. This study is of relevance in any ULF-NMR experiment, as in the ULF regime spurious ferromagnetism becomes easily a dominant cause of artefacts.

physics.ins-det

Fast switching coil system for sample premagnetization in an unshielded ultra-low-field Nuclear Magnetic Resonance experiment

We present a system developed to premagnetize liquid samples in an ultra-low-field Nuclear Magnetic Resonance (NMR) experiment. Liquid samples of a few milliliter are exposed to a magnetic field of about 70~mT, which is abruptely switched off, so to leave a transverse microtesla field where nuclei start precessing. An accurate characterization of the transients and intermediate field level enables a reliable operation of the detection system, which is based on an optical magnetometer.

physics.ins-det

Sub-millimetric ultra-low-field MRI detected in situ by a dressed atomic magnetometer

Magnetic Resonance Imaging (MRI) is universally acknowledged as an excellent tool to extract detailed spatial information with minimally invasive measurements. Efforts toward ultra-low-field (ULF) MRI are made to simplify the scanners and to reduce artefacts and incompatibilities. Optical Atomic Magnetometers (OAMs) are among the sensitive magnetic detectors eligible for ULF operation, however they are not compatible with the strong field gradients used in MRI. We show that a magnetic-dressing technique restores the OAMs operability despite the gradient, and we demonstrate sub-millimetric resolution MRI with a compact experimental setup based on an in situ detection. The proof-of-concept experiment produces unidimensional imaging of remotely magnetized samples with a dual sensor, but the approach is suited to be adapted for 3-D imaging of samples magnetized in loco. An extension to multi-sensor architectures is also possible.

physics.app-ph

Spurious Ferromagnetic Remanence Detected by Hybrid Magnetometer

Nuclear magnetic resonance detection in ultra low field regime enables the measurement of different components of a spurious remanence in the polymeric material constituting the sample container. A differential atomic magnetometer detects simultaneously the static field generated by the container and the time-dependent signal from the precessing nuclei. The nuclear precession responds with frequency shifts and decay rate variations to the container magnetization. Two components of the latter act independently on the atomic sensor and on the nuclear sample. A model of the measured signal allows a detailed interpretation, on the basis of the interaction geometry.

physics.ins-det

Restoring Narrow Linewidth to a Gradient-Broadened Magnetic Resonance by Inhomogeneous Dressing

We study the possibility of counteracting the line-broadening of atomic magnetic resonances due to inhomogeneities of the static magnetic field by means of spatially dependent magnetic dressing, driven by an alternating field that oscillates much faster than the Larmor precession frequency. We demonstrate that an intrinsic resonance linewidth of 25~Hz that has been broadened up to hundreds Hz by a magnetic field gradient, can be recovered by the application of an appropriate inhomogeneous dressing field. The findings of our experiments may have immediate and important implications, because they facilitate the use of atomic magnetometers as robust, high sensitivity detectors in ultra-low-field NMR imaging.

physics.atom-ph