Searcharxiv⌕ Search

arXiv subjects

Valerio Biancalana

Publications and source records attributed to Valerio Biancalana.

26 records · Page 2Linked to original sources

Self-adaptive loop for external disturbance reduction in differential measurement set-up

We present a method developed to actively compensate common-mode magnetic disturbances on a multi-sensor device devoted to differential measurements. The system uses a field-programmable-gated-array card, and operates in conjunction with a high sensitivity magnetometer: compensating the common-mode of magnetic disturbances results in a relevant reduction of the difference-mode noise. The digital nature of the compensation system allows for using a numerical approach aimed at automatically adapting the feedback loop filter response. A common mode disturbance attenuation exceeding 50 dB is achieved, resulting in a final improvement of the differential noise floor by a factor of 10 over the whole spectral interval of interest.

physics.ins-det↗

Simultaneous Detection of H and D NMR Signals in a micro-Tesla Field

We present NMR spectra of remote-magnetized deuterated water, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed in a $μ$T field, while pulsed techniques are applied -following the sample displacement- in a 100~$μ$T field, to tip both D and H nuclei by controllable amounts. The broadband nature of the detection system enables simultaneous detection of the two signals and accurate evaluation of their decay times. The outcomes of the experiment demonstrate the potential of ultra-low-field NMR spectroscopy in important applications where the correlation between proton and deuteron spin-spin relaxation rates as a function of external parameters contains significant information.

physics.chem-ph↗

A low noise modular current source for stable magnetic field control

A low cost, stable, programmable, unipolar current source is described. The circuit is designed in view of a modular arrangement, suitable for applications where several DC sources must be controlled at once. A hybrid switching/linear design helps in improving the stability and in reducing the power dissipation and cross-talking. Multiple units can be supplied by a single DC power supply, while allowing for a variety of maximal current values and compliance voltages at the outputs. The circuit is analogically controlled by an unipolar voltage, enabling current programmability and control through commercial digital-to-analogue conversion cards.

physics.ins-det↗

Multichannel optical atomic magnetometer operating in unshielded environment

A multi-channel atomic magnetometer operating in an unshielded environment is described and characterised. The magnetometer is based on D1 optical pumping and D2 polarimetry of Cs vapour contained in gas-buffered cells. Several technical implementations are described and discussed in detail. The demonstrated sensitivity of the setup is 100fT/Hz^1/2 when operating in the difference mode.

physics.ins-det↗

Microtesla NMR J-coupling spectroscopy with an unshielded atomic magnetometer

We present experimental data and theoretical interpretation of NMR spectra of remotely magnetized samples, detected in an unshielded environment by means of a differential atomic magnetometer. The measurements are performed in an ultra-low-field at an intermediate regime, where the J-coupling and the Zeeman energies have comparable values and produce rather complex line sets, which are satisfactorily interpreted.

physics.chem-ph↗

A fast pneumatic sample-shuttle with attenuated shocks

We describe a home-built pneumatic shuttle suitable for the fast displacement of samples in the vicinity of a highly sensitive atomic magnetometer. The samples are magnetized at 1 T using a Halbach assembly of magnets. The device enables the remote detection of free induction decay in ultra-low-field and zero-field NMR experiments, in relaxometric measurements and in other applications involving the displacement of magnetized samples within time intervals as short as a few tens of milliseconds. Other possible applications of fast sample shuttling exist in radiological studies, where samples have to be irradiated and then analyzed in a 'cold' environment.

physics.ins-det↗

Stray Magnetic Field Compensation with a Scalar Atomic Magnetometer

We describe a system for the compensation of time-dependent stray magnetic fields using a dual channel scalar magnetometer based on non-linear Faraday rotation in synchronously optically pumped Cs vapour. We detail the active control strategy, with an emphasis on the electronic circuitry, based on a simple phase-locked-loop integrated circuit. The performance and limits of the system developed are tested and discussed. The system was applied to significantly improve the detection of free induction decay signals from protons of remotely magnetized water precessing in an ultra-low magnetic field.

physics.ins-det↗

All-optical magnetometry for NMR detection in a micro-Tesla field and unshielded environment

An all-optical atomic magnetometer is used to detect a proton free-precession signal from a water sample polarized in a 0.7 T field and remotely analyzed in a 4 $μT$ field. Nuclear spins are manipulated either by $π/2$ pulses or by non-adiabatic rotation. The magnetometer operates at room temperature, in an unshielded environment and has a dual-channel sensor for differential measurements.

physics.atom-ph↗