SearcharxivSearch

arXiv subjects

Victor Kartsch

Publications and source records attributed to Victor Kartsch.

17 recordsLinked to original sources

High-Speed, Scalable Sensor Readout for Dexterous Robotic Hands via Shift-Register Multiplexing

Dexterous robotic hands require high-speed multimodal sensing across many degrees of freedom, yet existing readout architectures often impose trade-offs between sensor count, wiring complexity, and sampling bandwidth. This paper presents a scalable analog sensor readout architecture based on a serial-in parallel-out (SIPO) shift-register principle. The proposed architecture supports versatile integration of heterogeneous analog-output sensors, scalable expansion using only three signal lines between sensor modules, and fast, configurable sampling. We validate the approach on a tendon-driven robotic hand integrating 16 joint sensor modules and one four-channel tactile sensor module, enabling acquisition of 20 sensor channels at a full-scan rate of 1 kHz, with stable operation up to 1.5 kHz. Joint sensor characterization showed a maximum slope absolute percentage error (APE) of 0.446% and sub-degree estimation error, indicating that the proposed readout system does not significantly degrade sensing performance. For tactile sensing, LSTM-based models achieved an RMSE of 0.125 N for force estimation and 93.4% accuracy for five-class contact-location classification, and were deployed for real-time inference at 1 kHz. System-level experiments showed that the joint sensors provide more accurate feedback than motor-based estimation during interaction, while the tactile sensor enables responsive force estimation in contact. The proposed architecture offers a practical path toward fully sensorized robotic hands for dexterous manipulation.

cs.RO

SilentWear: an Ultra-Low Power Wearable System for EMG-based Silent Speech Recognition

Detecting speech from biosignals is gaining increasing attention due to the potential to develop human-computer interfaces that are noise-robust, privacy-preserving, and scalable for both clinical applications and daily use. However, most existing approaches remain limited by insufficient wearability and the lack of edge-processing capabilities, which are essential for minimally obtrusive, responsive, and private assistive technologies. In this work, we present SilentWear, a fully wearable, textile-based neck interface for EMG signal acquisition and processing. Powered by BioGAP-Ultra, the system enables end-to-end data acquisition from 14 differential channels and on-device speech recognition. SilentWear is coupled with SpeechNet, a lightweight 15k-parameter CNN architecture specifically tailored for EMG-based speech decoding, achieving an average cross-validated accuracy of 84.8$\pm$4.6% and 77.5$\pm$6.6% for vocalized and silent speech, respectively, over eight representative human-machine interaction commands collected over multiple days. We evaluate robustness to repositioning induced by multi-day use. In an inter-session setting, the system achieves average accuracies of 71.1$\pm$8.3% and 59.3\pm2.2% for vocalized and silent speech, respectively. To mitigate performance degradation due to repositioning, we propose an incremental fine-tuning strategy, demonstrating more than 10% accuracy recovery with less than 10 minutes of additional user data. Finally, we demonstrate end-to-end real-time on-device speech recognition on a commercial multi-core microcontroller unit (MCU), achieving an energy consumption of 63.9$\mu$J per inference with a latency of 2.47 ms. With a total power consumption of 20.5mW for acquisition, inference, and wireless transmission of results, SilentWear enables continuous operation for more than 27 hours.

eess.SP

Wearable and Ultra-Low-Power Fusion of EMG and A-Mode US for Hand-Wrist Kinematic Tracking

Hand gesture recognition based on biosignals has shown strong potential for developing intuitive human-machine interaction strategies that closely mimic natural human behavior. In particular, sensor fusion approaches have gained attention for combining complementary information and overcoming the limitations of individual sensing modalities, thereby enabling more robust and reliable systems. Among them, the fusion of surface electromyography (EMG) and A-mode ultrasound (US) is very promising. However, prior solutions rely on power-hungry platforms unsuitable for multi-day use and are limited to discrete gesture classification. In this work, we present an ultra-low-power (sub-50 mW) system for concurrent acquisition of 8-channel EMG and 4-channel A-mode US signals, integrating two state-of-the-art platforms into fully wearable, dry-contact armbands. We propose a framework for continuous tracking of 23 degrees of freedom (DoFs), 20 for the hand and 3 for the wrist, using a kinematic glove for ground-truth labeling. Our method employs lightweight encoder-decoder architectures with multi-task learning to simultaneously estimate hand and wrist joint angles. Experimental results under realistic sensor repositioning conditions demonstrate that EMG-US fusion achieves a root mean squared error of $10.6^\circ\pm2.0^\circ$, compared to $12.0^\circ\pm1^\circ$ for EMG and $13.1^\circ\pm2.6^\circ$ for US, and a R$^2$ score of $0.61\pm0.1$, with $0.54\pm0.03$ for EMG and $0.38\pm0.20$ for US.

eess.SP

BioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing

The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage (x2 SRAM, x4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, x4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels (x2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system's versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.

eess.SY

A Multi-Modal IoT Node for Energy-Efficient Environmental Monitoring with Edge AI Processing

The widespread adoption of Internet of Things (IoT) technologies has significantly advanced environmental monitoring (EM) by enabling cost-effective and scalable sensing solutions. Concurrently, machine learning (ML) and artificial intelligence (AI) are introducing powerful tools for the efficient and accurate analysis of complex environmental data. However, current IoT platforms for environmental sensing are typically limited to a narrow set of sensors, preventing a comprehensive assessment of environmental conditions and lacking sufficient computational capabilities to support the deployment of advanced ML and AI algorithms on the edge. To overcome these limitations, we introduce a compact (17x38 mm2), multi-modal, MCU-based environmental IoT node integrating 11 sensors, including CO2 concentration, volatile organic compounds (VOCs), light intensity, UV radiation, pressure, temperature, humidity, visual sensing via an RGB camera, and precise geolocation through a GNSS module. It features GAP9, a parallel ultra-low-power system-on-chip, enabling real-time, energy-efficient edge processing of advanced ML models directly on-device. We implemented a YOLOv5-based occupancy detection pipeline (0.3 M parameters, 42 MOP per inference), demonstrating 42% energy savings over raw data streaming. Additionally, we present a smart indoor air quality (IAQ) monitoring setup that combines occupancy detection with adaptive sample rates, achieving operational times of up to 143 h on a single compact 600 mAh, 3.7 V battery. Our platform lays the groundwork for innovative applications such as predictive indoor IAQ, enabling efficient AI-driven on-edge forecasting for energy-efficient and autonomous, proactive pollution-mitigation control strategies

eess.SP

Real-Time, Single-Ear, Wearable ECG Reconstruction, R-Peak Detection, and HR/HRV Monitoring

Biosignal monitoring, in particular heart activity through heart rate (HR) and heart rate variability (HRV) tracking, is vital in enabling continuous, non-invasive tracking of physiological and cognitive states. Recent studies have explored compact, head-worn devices for HR and HRV monitoring to improve usability and reduce stigma. However, this approach is challenged by the current reliance on wet electrodes, which limits usability, the weakness of ear-derived signals, making HR/HRV extraction more complex, and the incompatibility of current algorithms for embedded deployment. This work introduces a single-ear wearable system for real-time ECG (Electrocardiogram) parameter estimation, which directly runs on BioGAP, an energy-efficient device for biosignal acquisition and processing. By combining SoA in-ear electrode technology, an optimized DeepMF algorithm, and BioGAP, our proposed subject-independent approach allows for robust extraction of HR/HRV parameters directly on the device with just 36.7 uJ/inference at comparable performance with respect to the current state-of-the-art architecture, achieving 0.49 bpm and 25.82 ms for HR/HRV mean errors, respectively and an estimated battery life of 36h with a total system power consumption of 7.6 mW. Clinical relevance: The ability to reconstruct ECG signals and extract HR and HRV paves the way for continuous, unobtrusive cardiovascular monitoring with head-worn devices. In particular, the integration of cardiovascular measurements in everyday-use devices (such as earbuds) has potential in continuous at-home monitoring to enable early detection of cardiovascular irregularities.

eess.SP

On-Device Federated Continual Learning on RISC-V-based Ultra-Low-Power SoC for Intelligent Nano-Drone Swarms

RISC-V-based architectures are paving the way for efficient On-Device Learning (ODL) in smart edge devices. When applied across multiple nodes, ODL enables the creation of intelligent sensor networks that preserve data privacy. However, developing ODL-capable, battery-operated embedded platforms presents significant challenges due to constrained computational resources and limited device lifetime, besides intrinsic learning issues such as catastrophic forgetting. We face these challenges by proposing a regularization-based On-Device Federated Continual Learning algorithm tailored for multiple nano-drones performing face recognition tasks. We demonstrate our approach on a RISC-V-based 10-core ultra-low-power SoC, optimizing the ODL computational requirements. We improve the classification accuracy by 24% over naive fine-tuning, requiring 178 ms per local epoch and 10.5 s per global epoch, demonstrating the effectiveness of the architecture for this task.

cs.LG

BatDeck -- Ultra Low-power Ultrasonic Ego-velocity Estimation and Obstacle Avoidance on Nano-drones

Nano-drones, with their small, lightweight design, are ideal for confined-space rescue missions and inherently safe for human interaction. However, their limited payload restricts the critical sensing needed for ego-velocity estimation and obstacle detection to single-bean laser-based time-of-flight (ToF) and low-resolution optical sensors. Although those sensors have demonstrated good performance, they fail in some complex real-world scenarios, especially when facing transparent or reflective surfaces (ToFs) or when lacking visual features (optical-flow sensors). Taking inspiration from bats, this paper proposes a novel two-way ranging-based method for ego-velocity estimation and obstacle avoidance based on down-and-forward facing ultra-low-power ultrasonic sensors, which improve the performance when the drone faces reflective materials or navigates in complete darkness. Our results demonstrate that our new sensing system achieves a mean square error of 0.019 m/s on ego-velocity estimation and allows exploration for a flight time of 8 minutes while covering 136 m on average in a challenging environment with transparent and reflective obstacles. We also compare ultrasonic and laser-based ToF sensing techniques for obstacle avoidance, as well as optical flow and ultrasonic-based techniques for ego-velocity estimation, denoting how these systems and methods can be complemented to enhance the robustness of nano-drone operations.

cs.RO

Circuits and Systems for Embodied AI: Exploring uJ Multi-Modal Perception for Nano-UAVs on the Kraken Shield

Embodied artificial intelligence (AI) requires pushing complex multi-modal models to the extreme edge for time-constrained tasks such as autonomous navigation of robots and vehicles. On small form-factor devices, e.g., nano-sized unmanned aerial vehicles (UAVs), such challenges are exacerbated by stringent constraints on energy efficiency and weight. In this paper, we explore embodied multi-modal AI-based perception for Nano-UAVs with the Kraken shield, a 7g multi-sensor (frame-based and event-based imagers) board based on Kraken, a 22 nm SoC featuring multiple acceleration engines for multi-modal event and frame-based inference based on spiking (SNN) and ternary (TNN) neural networks, respectively. Kraken can execute SNN real-time inference for depth estimation at 1.02k inf/s, 18 {\mu}J/inf, TNN real-time inference for object classification at 10k inf/s, 6 {\mu}J/inf, and real-time inference for obstacle avoidance at 221 frame/s, 750 {\mu}J/inf.

cs.AR

An Ultra-Low Power Wearable BMI System with Continual Learning Capabilities

Driven by the progress in efficient embedded processing, there is an accelerating trend toward running machine learning models directly on wearable Brain-Machine Interfaces (BMIs) to improve portability and privacy and maximize battery life. However, achieving low latency and high classification performance remains challenging due to the inherent variability of electroencephalographic (EEG) signals across sessions and the limited onboard resources. This work proposes a comprehensive BMI workflow based on a CNN-based Continual Learning (CL) framework, allowing the system to adapt to inter-session changes. The workflow is deployed on a wearable, parallel ultra-low power BMI platform (BioGAP). Our results based on two in-house datasets, Dataset A and Dataset B, show that the CL workflow improves average accuracy by up to 30.36% and 10.17%, respectively. Furthermore, when implementing the continual learning on a Parallel Ultra-Low Power (PULP) microcontroller (GAP9), it achieves an energy consumption as low as 0.45mJ per inference and an adaptation time of only 21.5ms, yielding around 25h of battery life with a small 100mAh, 3.7V battery on BioGAP. Our setup, coupled with the compact CNN model and on-device CL capabilities, meets users' needs for improved privacy, reduced latency, and enhanced inter-session performance, offering good promise for smart embedded real-world BMIs.

eess.SP

Train-On-Request: An On-Device Continual Learning Workflow for Adaptive Real-World Brain Machine Interfaces

Brain-machine interfaces (BMIs) are expanding beyond clinical settings thanks to advances in hardware and algorithms. However, they still face challenges in user-friendliness and signal variability. Classification models need periodic adaptation for real-life use, making an optimal re-training strategy essential to maximize user acceptance and maintain high performance. We propose TOR, a train-on-request workflow that enables user-specific model adaptation to novel conditions, addressing signal variability over time. Using continual learning, TOR preserves knowledge across sessions and mitigates inter-session variability. With TOR, users can refine, on demand, the model through on-device learning (ODL) to enhance accuracy adapting to changing conditions. We evaluate the proposed methodology on a motor-movement dataset recorded with a non-stigmatizing wearable BMI headband, achieving up to 92% accuracy and a re-calibration time as low as 1.6 minutes, a 46% reduction compared to a naive transfer learning workflow. We additionally demonstrate that TOR is suitable for ODL in extreme edge settings by deploying the training procedure on a RISC-V ultra-low-power SoC (GAP9), resulting in 21.6 ms of latency and 1 mJ of energy consumption per training step. To the best of our knowledge, this work is the first demonstration of an online, energy-efficient, dynamic adaptation of a BMI model to the intrinsic variability of EEG signals in real-time settings.

eess.SP

GAP9Shield: A 150GOPS AI-capable Ultra-low Power Module for Vision and Ranging Applications on Nano-drones

The evolution of AI and digital signal processing technologies, combined with affordable energy-efficient processors, has propelled the development of both hardware and software for drone applications. Nano-drones, which fit into the palm of the hand, are suitable for indoor environments and safe for human interaction; however, they often fail to deliver the required performance for complex tasks due to the lack of hardware providing sufficient sensing and computing performance. Addressing this gap, we present the GAP9Shield, a nano-drone-compatible module powered by the GAP9, a 150GOPS-capable SoC. The system also includes a 5MP OV5647 camera for high-definition imaging, a WiFi-BLE NINA module, and a 5D VL53L1-based ranging subsystem, which enhances obstacle avoidance capabilities. In comparison with similarly targeted state-of-the-art systems, GAP9Shield provides a 20% higher sample rate (RGB images) while offering a 20% weight reduction. In this paper, we also highlight the energy efficiency and processing power capabilities of GAP9 for object detection (YOLO), localization, and mapping, which can run within a power envelope of below 100 mW and at low latency (as 17 ms for object detection), highlighting the transformative potential of GAP9 for the new generation of nano-drone applications.

cs.RO

GAPses: Versatile smart glasses for comfortable and fully-dry acquisition and parallel ultra-low-power processing of EEG and EOG

Recent advancements in head-mounted wearable technology are revolutionizing the field of biopotential measurement, but the integration of these technologies into practical, user-friendly devices remains challenging due to issues with design intrusiveness, comfort, and data privacy. To address these challenges, this paper presents GAPses, a novel smart glasses platform designed for unobtrusive, comfortable, and secure acquisition and processing of electroencephalography (EEG) and electrooculography (EOG) signals. We introduce a direct electrode-electronics interface with custom dry soft electrodes to enhance comfort for long wear. An integrated parallel ultra-low-power RISC-V processor (GAP9, Greenwaves Technologies) processes data at the edge, thereby eliminating the need for continuous data streaming through a wireless link, enhancing privacy, and increasing system reliability in adverse channel conditions. We demonstrate the broad applicability of the designed prototype through validation in a number of EEG-based interaction tasks, including alpha waves, steady-state visual evoked potential analysis, and motor movement classification. Furthermore, we demonstrate an EEG-based biometric subject recognition task, where we reach a sensitivity and specificity of 98.87% and 99.86% respectively, with only 8 EEG channels and an energy consumption per inference on the edge as low as 121 $\mu J$. Moreover, in an EOG-based eye movement classification task, we reach an accuracy of 96.68% on 11 classes, resulting in an information transfer rate of 94.78 bit/min, which can be further increased to 161.43 bit/min by reducing the accuracy to 81.43%. The deployed implementation has an energy consumption of 40 $\mu J$ per inference and a total system power of only 12.4 mW, of which only 1.61% is used for classification, allowing for continuous operation of more than 22 h with a small 75 mAh battery.

eess.SP

Enhancing Performance, Calibration Time and Efficiency in Brain-Machine Interfaces through Transfer Learning and Wearable EEG Technology

Brain-machine interfaces (BMIs) have emerged as a transformative force in assistive technologies, empowering individuals with motor impairments by enabling device control and facilitating functional recovery. However, the persistent challenge of inter-session variability poses a significant hurdle, requiring time-consuming calibration at every new use. Compounding this issue, the low comfort level of current devices further restricts their usage. To address these challenges, we propose a comprehensive solution that combines a tiny CNN-based Transfer Learning (TL) approach with a comfortable, wearable EEG headband. The novel wearable EEG device features soft dry electrodes placed on the headband and is capable of on-board processing. We acquire multiple sessions of motor-movement EEG data and achieve up to 96% inter-session accuracy using TL, greatly reducing the calibration time and improving usability. By executing the inference on the edge every 100ms, the system is estimated to achieve 30h of battery life. The comfortable BMI setup with tiny CNN and TL paves the way to future on-device continual learning, essential for tackling inter-session variability and improving usability.

eess.SP

BatDeck: Advancing Nano-drone Navigation with Low-power Ultrasound-based Obstacle Avoidance

Nano-drones, distinguished by their agility, minimal weight, and cost-effectiveness, are particularly well-suited for exploration in confined, cluttered and narrow spaces. Recognizing transparent, highly reflective or absorbing materials, such as glass and metallic surfaces is challenging, as classical sensors, such as cameras or laser rangers, often do not detect them. Inspired by bats, which can fly at high speeds in complete darkness with the help of ultrasound, this paper introduces \textit{BatDeck}, a pioneering sensor-deck employing a lightweight and low-power ultrasonic sensor for nano-drone autonomous navigation. This paper first provides insights about sensor characteristics, highlighting the influence of motor noise on the ultrasound readings, then it introduces the results of extensive experimental tests for obstacle avoidance (OA) in a diverse environment. Results show that \textit{BatDeck} allows exploration for a flight time of 8 minutes while covering 136m on average before crash in a challenging environment with transparent and reflective obstacles, proving the effectiveness of ultrasonic sensors for OA on nano-drones.

cs.RO

A Wearable Ultra-Low-Power sEMG-Triggered Ultrasound System for Long-Term Muscle Activity Monitoring

Surface electromyography (sEMG) is a well-established approach to monitor muscular activity on wearable and resource-constrained devices. However, when measuring deeper muscles, its low signal-to-noise ratio (SNR), high signal attenuation, and crosstalk degrade sensing performance. Ultrasound (US) complements sEMG effectively with its higher SNR at high penetration depths. In fact, combining US and sEMG improves the accuracy of muscle dynamic assessment, compared to using only one modality. However, the power envelope of US hardware is considerably higher than that of sEMG, thus inflating energy consumption and reducing the battery life. This work proposes a wearable solution that integrates both modalities and utilizes an EMG-driven wake-up approach to achieve ultra-low power consumption as needed for wearable long-term monitoring. We integrate two wearable state-of-the-art (SoA) US and ExG biosignal acquisition devices to acquire time-synchronized measurements of the short head of the biceps. To minimize power consumption, the US probe is kept in a sleep state when there is no muscle activity. sEMG data are processed on the probe (filtering, envelope extraction and thresholding) to identify muscle activity and generate a trigger to wake-up the US counterpart. The US acquisition starts before muscle fascicles displacement thanks to a triggering time faster than the electromechanical delay (30-100 ms) between the neuromuscular junction stimulation and the muscle contraction. Assuming a muscle contraction of 200 ms at a contraction rate of 1 Hz, the proposed approach enables more than 59% energy saving (with a full-system average power consumption of 12.2 mW) as compared to operating both sEMG and US continuously.

eess.SY

BioGAP: a 10-Core FP-capable Ultra-Low Power IoT Processor, with Medical-Grade AFE and BLE Connectivity for Wearable Biosignal Processing

Wearable biosignal processing applications are driving significant progress toward miniaturized, energy-efficient Internet-of-Things solutions for both clinical and consumer applications. However, scaling toward high-density multi-channel front-ends is only feasible by performing data processing and machine Learning (ML) near-sensor through energy-efficient edge processing. To tackle these challenges, we introduce BioGAP, a novel, compact, modular, and lightweight (6g) medical-grade biosignal acquisition and processing platform powered by GAP9, a ten-core ultra-low-power SoC designed for efficient multi-precision (from FP to aggressively quantized integer) processing, as required for advanced ML and DSP. BioGAPs form factor is 16x21x14 mm$^3$ and comprises two stacked PCBs: a baseboard integrating the GAP9 SoC, a wireless Bluetooth Low Energy (BLE) capable SoC, a power management circuit, and an accelerometer; and a shield including an analog front-end (AFE) for ExG acquisition. Finally, the system also includes a flexibly placeable photoplethysmogram (PPG) PCB with a size of 9x7x3 mm$^3$ and a rechargeable battery ($ϕ$ 12x5 mm$^2$). We demonstrate BioGAP on a Steady State Visually Evoked Potential (SSVEP)-based Brain-Computer Interface (BCI) application. We achieve 3.6 uJ/sample in streaming and 2.2 uJ/sample in onboard processing mode, thanks to an efficiency on the FFT computation task of 16.7 Mflops/s/mW with wireless bandwidth reduction of 97%, within a power budget of just 18.2 mW allowing for an operation time of 15 h.

eess.SY