SearcharxivSearch

arXiv · 2508.13728

BioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing

Abstract

The growing demand for continuous physiological monitoring and human-machine interaction in real-world settings calls for wearable platforms that are flexible, low-power, and capable of on-device intelligence. This work presents BioGAP-Ultra, an advanced multimodal biosensing platform that supports synchronized acquisition of diverse electrophysiological and hemodynamic signals such as EEG, EMG, ECG, and PPG while enabling embedded AI processing at state-of-the-art energy efficiency. BioGAP-Ultra is a major extension of our previous BioGAP design aimed at meeting the rapidly growing requirements of wearable biosensing applications. It features (i) increased on-device storage (x2 SRAM, x4 FLASH), (ii) improved wireless connectivity (supporting up to 1.4 Mbit/s bandwidth, x4 higher than BioGAP), (iii) enhanced number of signal modalities (from 3 to 5) and analog input channels (x2). Further, it is accompanied by a real-time visualization and analysis software suite that supports the hardware design, providing access to raw data and real-time configurability on a mobile phone. Finally, we demonstrate the system's versatility through integration into various wearable form factors: an EEG-PPG headband consuming 32.8 mW, an EMG sleeve at 26.7 mW, and an ECG-PPG chestband requiring only 9.3 mW for continuous acquisition and streaming, tailored for diverse biosignal applications. To showcase its edge-AI capabilities, we further deploy two representative on-device applications: (1) ECG-PPG-based PAT estimation at 8.6 mW, and (2) EMG-ACC-based classification of reach-and-grasp motion phases, achieving 79.9 % $\pm$ 5.7 % accuracy at 23.6 mW. All hardware and software design files are also released open-source with a permissive license.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Sebastian Frey, Giusy Spacone, Andrea Cossettini, Marco Guermandi, Philipp Schilk, Luca Benini, Victor Kartsch. 2025-08-19. BioGAP-Ultra: A Modular Edge-AI Platform for Wearable Multimodal Biosignal Acquisition and Processing. https://arxiv.org/abs/2508.13728

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Structured Stochastic Representations of Integrated Dynamic Strategies

Dynamic allocation decisions couple present resource use to evolving internal conditions, delayed returns, and future costs. We represent this interaction by four probability localizations linked through regime-indexed, graph-constrained column-stochastic operators. Pre-action state or context selects a locally affine model, while action-dependent changes update subsequent regimes, yielding a causal switched representation of nonlinear evolution. We characterize operator identifiability relative to the graph, the stochastic constraints, and the sampled embedding, separating coefficient recovery from predictive equivalence on the decision domain. Decision making is then formulated through implementable return--cost acceptability regions. Finite-horizon error propagation supplies conservative classification margins, and simultaneous intervals distinguish model-relative near-optimality from certified $\epsilon$-optimality over a declared finite policy class. Regime-indexed stochastic feedback is admitted when it satisfies the same certification test. Reproducible synthetic laboratories for personal preparation, supplier participation, and customer retention illustrate exact, operator-supplied, and noisy feedback cases. Multinomial experiments show improving recovery of the feedback function and fewer unresolved decisions with increasing sample size, while unrestricted off-policy recovery remains limited. The contribution is a structure-preserving representation--identification--decision workflow, not a domain-specific physiological or commercial calibration.

eess.SY

Fusion Estimation in Multi-sensor Systems for Data Packets with Disrupted Identities

In this paper, we explore the problem of fusion estimation for a multi-sensor system where the identity of the data packet received by each sensor may be disrupted or incorrect due to confusion in device identity allocation, communication protocol defects, or the lack of a clear sensor identifier. This can result in a random shuffle of the data components during the fusion estimation process, compromising the performance of the fusion estimation. To address this issue, we introduce the concepts of permutations and symmetry groups to describe this phenomenon as data packet permutation. We construct statistics to simplify the information set, developing two algorithms: a Bayesian approach, which performs fusion using posterior arrangement probabilities, and a greedy approach, which effectively improves estimation performance by guessing the likely data arrangement. We compare these two algorithms and demonstrate that both are expectation error-bounded. We improve algorithms for information-scarce scenarios. By employing the expectation-maximization algorithm, we fill in the prior information of data arrangement where the correct convergence is proven. Finally, we present numerical simulations to validate our results.

eess.SY

Quantifying the Reality Gap for RL-Based UAV Placement at mmWave and Sub-THz

Reinforcement learning (RL) policies for unmanned aerial vehicle (UAV) placement in mmWave and sub-terahertz networks are typically trained on simplified analytical channels. We quantify the resulting sim-to-real gap on a real urban map of Doha, Qatar, at carriers {28, 140, 183, 300} GHz and altitudes {50, 75, 100, 125} m, evaluating three channel pipelines: an analytical model (FSPL + atmospheric absorption + cuboid LoS), full Monte-Carlo ray tracing in Sionna RT with ITU-R P.676-13 absorption, and a deterministic-LoS hybrid that reuses Sionna's mesh under a closed-form path-gain expression. We formalize the gap on the spatial SNR distribution via four metrics, namely bias, RMSE, Jensen-Shannon divergence, and optimum-deployment displacement. Three findings emerge: at 28/140 GHz, $\sim$70% of the apparent -5.6/-4.8 dB Sionna bias is Monte-Carlo undersampling and shrinks to -1.7/-1.5 dB after mitigation; at 183 GHz a -9.2 dB residual isolates the atmospheric absorption / ITU-R P.676 line-shape disagreement; at 300 GHz the stochastic ray tracer agrees with the analytical model only coincidentally, with a +3.8 dB structural offset exposed by the deterministic-LoS pipeline. Across all carriers the linear-domain regret of the analytical-trained policy stays $\geq$ 0.93, indicating practical near-optimality but with a carrier-resolved SNR bias that warrants explicit reporting.

eess.SY