SearcharxivSearch

arXiv subjects

Wanheng Lu

Publications and source records attributed to Wanheng Lu.

3 recordsLinked to original sources

From Artefact to Insight: Efficient Low-Rank Adaptation of BrushNet for Scanning Probe Microscopy Image Restoration

Scanning Probe Microscopy or SPM offers nanoscale resolution but is frequently marred by structured artefacts such as line scan dropout, gain induced noise, tip convolution, and phase hops. While most available methods treat SPM artefact removal as isolated denoising or interpolation tasks, the generative inpainting perspective remains largely unexplored. In this work, we introduce a diffusion based inpainting framework tailored to scientific grayscale imagery. By fine tuning less than 0.2 percent of BrushNet weights with rank constrained low rank adaptation (LoRA), we adapt a pretrained diffusion model using only 7390 artefact, clean pairs distilled from 739 experimental scans. On our forthcoming public SPM InpBench benchmark, the LoRA enhanced model lifts the Peak Signal to Noise Ratio or PSNR by 6.61 dB and halves the Learned Perceptual Image Patch Similarity or LPIPS relative to zero-shot inference, while matching or slightly surpassing the accuracy of full retraining, trainable on a single GPU instead of four high-memory cards. The approach generalizes across various SPM image channels including height, amplitude and phase, faithfully restores subtle structural details, and suppresses hallucination artefacts inherited from natural image priors. This lightweight framework enables efficient, scalable recovery of irreplaceable SPM images and paves the way for a broader diffusion model adoption in nanoscopic imaging analysis.

cs.CV

Variation of Contact Resonance Frequency during Domain Switching in PFM Measurements for Ferroelectric Materials

Piezoresponse Force Spectroscopy (PFS) is a powerful method widely used for measuring the nanoscale ferroelectric responses of the materials. However, it is found that certain non-ferroelectric materials can also generate similar responses from the PFS measurements due to many other factors, hence, it is believed that PFS alone is not sufficient to differentiate the ferroelectric and non-ferroelectric materials. On the other hands, this work shows that there are distinct differences in contact resonance frequency variation during the PFS measurements for ferroelectric and non-ferroelectric materials. Therefore, a new, simple and effective method is proposed to differentiate the responses from the ferroelectric and non-ferroelectric materials, this new analysis uses contact resonance frequency responses during the PFS measurements as a new parameter to differentiate the PFS measured responses from different materials.

cond-mat.mtrl-sci