Searcharxiv⌕ Search

arXiv subjects

Wenxiang Cong

Publications and source records attributed to Wenxiang Cong.

At least 37 records · Page 2Linked to original sources

Monochromatic CT Image Reconstruction from Current-Integrating Data via Deep Learning

In clinical CT, the x-ray source emits polychromatic x-rays, which are detected in the current-integrating mode. This physical process is accurately described by an energy-dependent non-linear integral model on the basis of the Beer-Lambert law. However, the non-linear model is too complicated to be directly solved for the image reconstruction, and is often approximated to a linear integral model in the form of the Radon transform, basically ignoring energy-dependent information. This model approximation would generate inaccurate quantification of attenuation image and significant beam-hardening artifacts. In this paper, we develop a deep-learning-based CT image reconstruction method to address the mismatch of computing model to physical model. Our method learns a nonlinear transformation from big data to correct measured projection data to accurately match the linear integral model, realize monochromatic imaging and overcome beam hardening effectively. The deep-learning network is trained and tested using clinical dual-energy dataset to demonstrate the feasibility of the proposed methodology. Results show that the proposed method can achieve a high accuracy of the projection correction with a relative error of less than 0.2%.

physics.med-ph↗

Development of a focused-X-ray luminescence tomography (FXLT) system

Biophotonics is an active research area in molecular imaging, genetic diagnosis and prognosis, with direct applicability in precision medicine. However, long-standing challenges of biophotonics are well known due to low signal-to-noise ratio and poor image quality, mainly due to strong optical scattering especially in deep tissues. Recently, X-ray luminescence computed tomography (XLCT) has emerged as a hybrid molecular imaging modality and shown great promises in overcoming the optical scattering in deep tissues. However, its high spatial resolution capacity has not been fully implemented yet. In this paper, with a superfine focused X-ray beam we design a focused-X-ray luminescence tomography (FXLT) system for spatial resolution better than 150 micrometers and molecular sensitivity of 2 micromolar. First, we describe our system design. Then, we demonstrate that the molecular sensitivity of FXLT is about 5 micromolar considering the emitted visible photons from background. Furthermore, we analyze the measurement time per scan from measured photons numbers with a fiber bundle-PMT setup, report numerical and experimental results. Finally, we specify the imaging system performance based on numerical simulations and physical measurements.

physics.med-ph↗

General Backpropagation Algorithm for Training Second-order Neural Networks

The artificial neural network is a popular framework in machine learning. To empower individual neurons, we recently suggested that the current type of neurons could be upgraded to 2nd order counterparts, in which the linear operation between inputs to a neuron and the associated weights is replaced with a nonlinear quadratic operation. A single 2nd order neurons already has a strong nonlinear modeling ability, such as implementing basic fuzzy logic operations. In this paper, we develop a general backpropagation (BP) algorithm to train the network consisting of 2nd-order neurons. The numerical studies are performed to verify of the generalized BP algorithm.

cs.LG↗

Reconstruction of optical parameters for molecular tomographic imaging

Optical molecular tomographic imaging is to reconstruct the concentration distribution of photon-molecular probes in a small animal from measured photon fluence rates. The localization and quantification of molecular probes is related to tissue optical properties. The optical parameters can be reconstructed by the optimization method, in which the objective function is not convex, and there are multiple local optimal solutions. The gradient-based optimization algorithm could converge prematurely to an inaccurate solution if the initial guess is not close enough to the true solution. In this paper, we develop a hybrid algorithm combined global optimization and gradient-based optimization methods to reconstruct optical parameters. Differential evolution is an effective global optimizer, and could yield an estimated solution near the global optimal region to eliminate the need of initial guess of the optical parameters. The gradient-based optimization method is further performed with initial values obtained from DE to obtain local optimal solution for more accurate reconstruction of optical parameters. This proposed reconstruction method is evaluated by comprehensive numerical simulation experiments. The results show that the proposed method is stable and accurate for the reconstruction of optical parameters.

physics.bio-ph↗

A New Type of Neurons for Machine Learning

In machine learning, the use of an artificial neural network is the mainstream approach. Such a network consists of layers of neurons. These neurons are of the same type characterized by the two features: (1) an inner product of an input vector and a matching weighting vector of trainable parameters and (2) a nonlinear excitation function. Here we investigate the possibility of replacing the inner product with a quadratic function of the input vector, thereby upgrading the 1st order neuron to the 2nd order neuron, empowering individual neurons, and facilitating the optimization of neural networks. Also, numerical examples are provided to illustrate the feasibility and merits of the 2nd order neurons. Finally, further topics are discussed.

cs.NE↗

CT Image Reconstruction in a Low Dimensional Manifold

Regularization methods are commonly used in X-ray CT image reconstruction. Different regularization methods reflect the characterization of different prior knowledge of images. In a recent work, a new regularization method called a low-dimensional manifold model (LDMM) is investigated to characterize the low-dimensional patch manifold structure of natural images, where the manifold dimensionality characterizes structural information of an image. In this paper, we propose a CT image reconstruction method based on the prior knowledge of the low-dimensional manifold of CT image. Using the clinical raw projection data from GE clinic, we conduct comparisons for the CT image reconstruction among the proposed method, the simultaneous algebraic reconstruction technique (SART) with the total variation (TV) regularization, and the filtered back projection (FBP) method. Results show that the proposed method can successfully recover structural details of an imaging object, and achieve higher spatial and contrast resolution of the reconstructed image than counterparts of FBP and SART with TV.

physics.med-ph↗

Optical Tomographic Imaging for Breast Cancer Detection

Diffuse optical breast imaging utilizes near-infrared (NIR) light propagation through tissues to assess the optical properties of tissue for the identification of abnormal tissue. This optical imaging approach is sensitive, cost-effective, and does not involve any ionizing radiation. However, the image reconstruction of diffuse optical tomography (DOT) is a nonlinear inverse problem and suffers from severe ill-posedness, especially in the cases of strong noise and incomplete data. In this paper, a novel image reconstruction method is proposed for the detection of breast cancer. This method split the image reconstruction problem into the localization of abnormal tissues and quantification of absorption variations. The localization of abnormal tissues is performed based on a new well-posed optimization model, which can be solved via differential evolution optimization method to achieve a stable image reconstruction. The quantification of abnormal absorption variations is then determined in localized regions of relatively small extents, which are potentially tumors. Consequently, the number of unknown absorption variables can be greatly reduced to overcome the underdetermined nature of diffuse optical tomography (DOT), allowing for accurate and stable reconstruction of the abnormal absorption variations in the breast. Numerical simulation experiments show that the image reconstruction method is stable and accurate for the identification of abnormal tissues, and robust against measurement noise of data.

physics.med-ph↗

Theoretical analysis on x-ray cylindrical grating interferometer

Grating interferometer is a state of art x-ray imaging approach, which can simultaneously acquire information of x-ray attenuation, phase shift, and small angle scattering. This approach is very sensitive to micro-structural variation and offers superior contrast resolution for biological soft tissues. The present grating interferometer often uses flat gratings, with serious limitations in the field of view and the flux of photons. The use of curved gratings allows perpendicular incidence of x-rays on the gratings, and gives higher visibility over a larger field of view than a conventional interferometer with flat gratings. In the study, we present a rigorous theoretical analysis of the self-imaging of curved transmission gratings based on Rayleigh-Sommerfeld diffraction. Numerical simulations have demonstrated the self-imaging phenomenon of cylindrical grating interferometer. The theoretical results are in agreement with the results of numerical simulations.

physics.med-ph↗

A Pilot Study on Coupling CT and MRI through Use of Semiconductor Nanoparticles

CT and MRI are the two most widely used imaging modalities in healthcare, each with its own merits and drawbacks. Combining these techniques in one machine could provide unprecedented resolution and sensitivity in a single scan, and serve as an ideal platform to explore physical coupling of x-ray excitation and magnetic resonance. Molecular probes such as functionalized nanophosphors present an opportunity to demonstrate a synergy between these modalities. However, a simultaneous CT-MRI scanner does not exist at this moment. As a pilot study, here we propose a mechanism in which water solutions containing LiGa5O8:Cr3+ nanophosphors can be excited with x-rays to store energy, and these excited particles may subsequently influence the T2 relaxation times of the solutions so that a difference in T2 can be measured by MRI before and after x-ray excitation. The trends seen in our study suggest that a measurable effect may exist from x-ray excitation of the nanophosphors. However, there are several experimental conditions that hinder the clarity of the results to be statistically significant up to a commonly accepted level (p=0.05), including insoluble nanoparticles and inter-scan variability. Nevertheless, the initial results from our experiments seem a consistent and inspiring story that x-rays modify MRI T2 values around nanophosphors. Upon availability of soluble nanophosphors, we will repeat our experiments to confirm these observations.

physics.med-ph↗

Modulated Luminescent Tomography

We propose and analyze a mathematical model of Modulated Luminescent Tomography. We show that when single X-rays or focused X-rays are used as an excitation, the problem is similar to the inversion of weighted X-ray transforms. In particular, we give an explicit inversion in the case of Dual Cone X-ray excitation.

math.AP↗

Attenuation map reconstruction from TOF PET data

To reconstruct a radioactive tracer distribution with positron emission tomography (PET), the background attenuation correction is needed to eliminate image artifacts. Recent research shows that time-of-flight (TOF) PET data determine the attenuation sinogram up to a constant, and its gradient can be computed using an analytic algorithm. In this paper, we study a direct estimation of the sinogram only from TOF PET data. First, the gradient of the attenuation sinogram is estimated using the aforementioned algorithm. Then, a relationship is established to link the differential attenuation sinogram and the underlying attenuation background. Finally, an iterative algorithm is designed to determine the attenuation sinogram accurately and stably. A 2D numerical simulation study is conducted to verify the correctness of our proposed approach.

physics.med-ph↗

Top-level Design and Pilot Analysis of Low-end CT Scanners Based on Linear Scanning for Developing Countries

Purpose: The goal is to develop a new architecture for computed tomography (CT) which is at an ultra-low-dose for developing countries, especially in rural areas. Methods: The proposed scheme is inspired by the recently developed compressive sensing and interior tomography techniques, where the data acquisition system targets a region of interest (ROI) to acquire limited and truncated data. The source and detector are translated in opposite directions for either ROI reconstruction with one or more localized linear scans or global reconstruction by combining multiple ROI reconstructions. In other words, the popular slip ring is replaced by a translation based setup, and the instrumentation cost is reduced by a relaxation of the imaging speed requirement. Results: The various translational scanning modes are theoretically analyzed, and the scanning parameters are optimized. The numerical simulation results from different numbers of linear scans confirm the feasibility of the proposed scheme, and suggest two preferred low-end systems for horizontal and vertical patient positions respectively. Conclusion: Ultra-low-cost x-ray CT is feasible with our proposed combination of linear scanning, compressive sensing, and interior tomography. The proposed architecture can be tailored into permanent, movable, or reconfigurable systems as desirable. Advanced image registration and spectral imaging features can be included as well.

physics.med-ph↗

Micro-modulated luminescence tomography

Imaging depth of optical microscopy has been fundamentally limited to millimeter or sub-millimeter due to light scattering. X-ray microscopy can resolve spatial details of few microns deeply inside a sample but the contrast resolution is still inadequate to depict heterogeneous features at cellular or sub-cellular levels. To enhance and enrich biological contrast at large imaging depth, various nanoparticles are introduced and become essential to basic research and molecular medicine. Nanoparticles can be functionalized as imaging probes, similar to fluorescent and bioluminescent proteins. LiGa5O8:Cr3+ nanoparticles were recently synthesized to facilitate luminescence energy storage with x-ray pre-excitation and the subsequently stimulated luminescence emission by visible/near-infrared (NIR) light. In this paper, we suggest a micro-modulated luminescence tomography (MLT) approach to quantify a nanophosphor distribution in a thick biological sample with high resolution. Our numerical simulation studies demonstrate the feasibility of the proposed approach.

physics.bio-ph↗

Stored Luminescence Computed Tomography

The phosphor nanoparticles made of doped semiconductors, pre-excited by well-collimated X-ray radiation, were recently reported for their light emission upon NIR light stimulation. The characteristics of X-ray energy storage and NIR stimulated emission is highly desirable to design targeting probes and improve molecular and cellular imaging. Here we propose stored luminescence computed tomography (SLCT), perform realistic numerical simulation, and demonstrate a much-improved spatial resolution in a preclinical research context. The future opportunities are also discussed along this direction.

physics.bio-ph↗

Dynamic Bowtie for Fan-beam CT

A bowtie is a filter used to shape an x-ray beam and equalize its flux reaching different detector channels. For development of spectral CT with energy-discriminative photon-counting (EDPC) detectors, here we propose and evaluate a dynamic bowtie for performance optimization based on a patient model or a scout scan. Our dynamic bowtie modifies an x-ray beam intensity profile by mechanical rotation and adaptive adjustment of the x-ray source flux. First, a mathematical model for dynamic bowtie filtering is established for an elliptical section in fan-beam geometry, and the contour of the optimal bowtie is derived. Then, numerical simulation is performed to compare the performance of the dynamic bowtie in the cases of an ideal phantom and a realistic cross-section relative to the counterparts without any bowtie and with a fixed bowtie respectively. Our dynamic bowtie can equalize the expected numbers of photons in the case of an ideal phantom. In practical cases, our dynamic bowtie can effectively reduce the dynamic range of detected signals inside the field of view. Although our design is optimized for an elliptical phantom, the resultant dynamic bowtie can be applied to a real fan-beam scan if the underlying cross-section can be approximated as an ellipse. Furthermore, our design methodology can be applied to specify an optimized dynamic bowtie for any cross-section of a patient, preferably using rapid prototyping technology. This fan-beam dynamic bowtie work could be extended to the cone-beam geometry in a follow-up study.

physics.med-ph↗

Analytic Comparison between X-ray Fluorescence CT and K-edge CT

X-ray fluorescence computed tomography (XFCT) and K-edge computed tomography (CT) are two important modalities to quantify a distribution of gold nanoparticles (GNPs) in a small animal for preclinical studies. It is valuable to determine which modality is more efficient for a given application. In this paper, we report a theoretical analysis in terms of signal-to-noise ratio (SNR) for the two modalities, showing that there is a threshold for the GNPs concentration and XFCT has a better SNR than K-edge CT if GNPs concentration is less than this threshold. Numerical simulations are performed and two kinds of phantoms are used to represent multiple concentration levels and feature sizes. Experimental results illustrate that XFCT is superior to K-edge CT when contrast concentration is lower than 0.4% which coincides with the theoretical analysis.

physics.med-ph↗

X-ray Fluorescence Sectioning

In this paper, we propose an x-ray fluorescence imaging system for elemental analysis. The key idea is what we call "x-ray fluorescence sectioning". Specifically, a slit collimator in front of an x-ray tube is used to shape x-rays into a fan-beam to illuminate a planar section of an object. Then, relevant elements such as gold nanoparticles on the fan-beam plane are excited to generate x-ray fluorescence signals. One or more 2D spectral detectors are placed to face the fan-beam plane and directly measure x-ray fluorescence data. Detector elements are so collimated that each element only sees a unique area element on the fan-beam plane and records the x-ray fluorescence signal accordingly. The measured 2D x-ray fluorescence data can be refined in reference to the attenuation characteristics of the object and the divergence of the beam for accurate elemental mapping. This x-ray fluorescence sectioning system promises fast fluorescence tomographic imaging without a complex inverse procedure. The design can be adapted in various ways, such as with the use of a larger detector size to improve the signal to noise ratio. In this case, the detector(s) can be shifted multiple times for image deblurring.

physics.med-ph↗

Differential Phase-contrast Interior Tomography

Differential phase contrast interior tomography allows for reconstruction of a refractive index distribution over a region of interest (ROI) for visualization and analysis of internal structures inside a large biological specimen. In this imaging mode, x-ray beams target the ROI with a narrow beam aperture, offering more imaging flexibility at less ionizing radiation. Inspired by recently developed compressive sensing theory, in numerical analysis framework, we prove that exact interior reconstruction can be achieved on an ROI via the total variation minimization from truncated differential projection data through the ROI, assuming a piecewise constant distribution of the refractive index in the ROI. Then, we develop an iterative algorithm for the interior reconstruction and perform numerical simulation experiments to demonstrate the feasibility of our proposed approach.

physics.med-ph↗